ENGLISH
16
THERMALAND TECHNICALCHARACTERISTICS
Pellet reserve capacity 26 kg
Overall performance circa 89,7 %
Water performance circa >80 %
Overall useable power 16 kW
Useable water power 14 kW
Min/max operating autonomy 6,5 / 26 hours
Min/max fuel consumption 1 / 4 kg/h
Minimum drawing quality 12 Pa
Maximum pressure 2,5 bar
Operating pressure 1-1,5 bar
Test EN14785 smoke outlet temperature 192,9 °C
Mass flow 9,0 g/s
CO Emissions (13% O2) 133 ppm
Weight including packaging (Charme - Karma - Feeling) 319 - 289 - 327 kg
Heatable volume 450 m
3
Smoke conduit diameter (male) 8 cm
ELECTRICALCHARACTERISTICS
Power supply 230Vac +/- 10% 50 Hz
on/off switch Yes
Mean power absorbed 120 W
Mean power absorbed during switching on 400 W
Remote control frequency (optional) infrared
Main power supply protection 2A, 250 Vac 5x20 fuse**
PCB protection 2A, 250 Vac 5x20 fuse**
* The heatable volume is calculated considering the use of pellets as per the note about fuel and that the house is insulated
as per Italian Law N° 10/91. ALOTDEPENDS ON HOW EFFICIENTTHE HEATERS ARE.
Legend
1 Aux
2 Control panel
3 Smoke RPM
4 Flow sensor
5 Smoke thermocouple
6 Water supply probe
7 Boiler water probe (optional)
8 230 VAC mains, fuse 2°
9 Smoke expulsion motor
10 TMSR 90°C
11 TM 150°C
12 Worm screw
13 Supply circulator
14 Boiler circulator (optional)
15 Switch resistance
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
PCB
The Dealer can install an optional on the AUX outlet (clean contact, with no potential) for controlling the process of swit-
ching on and off (e.g. telephone remote, local thermostat), located at the rear oh the stove.
Can be connected via special optional trestle (code 621240).
** placed at electric power cable input with spare fuse.
OPTIONALS
REMOTE CONTROL(cod. 281900)
GSM cellphone remote control for pellet stoves, for switching the stove on and off remotely via a text message.
TRESTLEAux port connection (code 621240)
sk tecnica charme karma feeling multilingua_FOTOCOP_mod.qxp 03/07/2009 12.24 Pagina 25