ROLE OF SAFETY DEVICES AND DETECTORS tted to the stove
Smoke thermocouple
on the smoke outlet. It reads the smoke temperature. It regulates the ignition stage and shuts the stove down if the temperature
is too high or too low (ame stop or excessive smoke temperature stop respectively).
Flow sensor
on the combustion air intake pipe. It detects whether the combustion air and outlet smoke are circulating correctly. It returns
a voltage signal which may be read on the detector status display. In the event of anomaly (which may be attributed to
INcorrect smoke outlet or combustion air intake), it shuts the stove down.
Screw feeder safety thermostat
near the pellet hopper. It cuts off the power supply to the gearmotor if the temperature measured is too high.
Water temperature detector
It reads the water temperature in the stove and sends the circuit board information for pump management and stove power
modulation.
If the temperature is too high, it starts a shutdown.
Water temperature safety thermostat
It reads the water temperature in the stove. If the temperature is too high, it starts a shutdown by cutting off the electricity
power supply to the gearmotor. If it has tripped, it may be reset by pressing the reset button behind the stove.
Overpressure valve
when the rated pressure is reached, it drains water from the system thus creating the need for a top up.
Pressure gauge
on the side of the stove. It shows the water pressure in the stove (recommended operating pressure between 1 and 1.5 bar).
IF THE STOVE SHUTS DOWN, THE REASON APPEARS ON THE DISPLAY AND IS STORED IN THE MEMORY
ROLE OF STOVE COMPONENTS
Heating element
It ignites the pellets. It remains on during the ignition stage until the smoke temperature increases by 15°C.
Smoke extractor
it “pushes” smoke out and draws fuel air in through the vacuum it creates.
Gearmotor
It moves the screw feeder and loads pellets from the hopper into the combustion chamber.
Pump (circulator)
it “pushes” the water out into the system. Maximum discharge head: 5 metres. Maximum ow rate: 2.5 m3/h.
Closed expansion tank
It “absorbs” the changes in the volume of the water inside the stove.
A separate expansion tank should be considered for the external system!
Manual bleed valve
found in the upper part. It may be used to “bleed off” any air.
Drain cock
found inside the stove at the bottom; it should be used to empty the boiler-stove of water.
ENGLISH
ENGLISH
24


Need help? Post your question in this forum.

Forumrules
1

Forum

edilkamin-idrotech

Reset search

  • quando la stufa non é funzionante nel display esce la scritta "bat 1" e lampeggia. qual'é il motivo? Submitted on 30-3-2022 at 15:44

    Reply Report abuse
    • Prova a cambiare la batteria del CMOS e tipo quella del telecomando della machina se non sbaglio 3510 Answered on 24-9-2022 at 01:04

      Vote up Report abuse
  • avendo un impianto piccolo vorrei attivare la funzione eco nella mia stufa idrotech come si fa? Submitted on 7-11-2021 at 19:54

    Reply Report abuse


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Edilkamin IDROTECH at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Edilkamin IDROTECH in the language / languages: English, German, Dutch, French, Italian, Spanish as an attachment in your email.

The manual is 4,43 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info