810888
15
Zoom out
Zoom in
Previous page
1/44
Next page
15
ENGLISH
HEATING AND DHW BOILER
Compatible kits are:
KIT R-FX
The heat demand may arise from:
the environmental probe input (if the detected temperature falls 1 °C below the set temperature);
the demand for DHW from the thermostat/boiler probe.
With a DHW demand, the boiler stove pump is switched on if the temperature in the boiler stove is 5 °C higher than
the boiler temperature and the three-way valve diverts to DHW. The distribution pump is off.
OPTIONAL HYDRAULIC KITS
All kits are supplied with instructions for their connection to the boiler stove.
The technicians have a dedicated paper template for each product. Make sure to use the correct template for the
model being installed.
Position the template flush with the floor and aligned with the left hand side of the outer edge boiler stove.
Remember to always observe the minimum installation distances, both from flammable materials and for maintenance.
WATER CIRCUIT INSTALLATION
HEATING AND INSTANT DHW
Compatible kits are:
• KIT R-FX
KIT RW-FX
KIT R2-FX
The heat demand may arise from:
the environmental probe input (if the detected temperature falls 1 °C below the set temperature);
the flow switch, when the DHW tap is opened.
The heat demand is shown on the display by a radiator or a tap symbol.
COMBINATION WITH ACCUMULATOR TANK
The Kits combinable with the accumulator are:
KIT R-FX
The accumulation probe must be set as accumulator tank probe
The demand for heating can be made:
by the thermostat/probe of the accumulator tank.
The pump of the boiler stove ensures the heat transfer from the boiler stove to the accumulator tank.
The (secondary) booster pump provides heat transfer from the accumulator tank to the system.
The timer programming on the display applies to the (secondary) booster pump.
These pages only include indications of possible installations and uses which must be
defined together with the installer and the Technical Assistance Centre during first ignition.
HYDRAULIC INSTALLATION EXAMPLES
N.B.: These diagrams are indicative, correct installation is the responsibility of the plumber
and the associated parameters should be set by the Technical Assistance Centre during
first ignition.
HEATING ONLY
Compatible kits are:
• KIT R-FX
• KIT R2-FX
The heat demand may arise from:
the environmental probe input (if the detected temperature falls 1 °C below the set temperature);
The heat demand is shown on the display by a radiator symbol.
15


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Edilkamin GORA at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Edilkamin GORA in the language / languages: English as an attachment in your email.

The manual is 1.3 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Edilkamin GORA

Edilkamin GORA User Manual - German - 44 pages

Edilkamin GORA Usermanual and installation guide - German - 40 pages

Edilkamin GORA Usermanual and installation guide - French, Italian - 80 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info