810851
11
Zoom out
Zoom in
Previous page
1/24
Next page
11
ENGLISH
FLUE SYSTEMFLUE SYSTEM
(Fumes duct, flue and chimney pot)(Fumes duct, flue and chimney pot)
This chapter has been drawn up pursuant to European
regulations EN 13384, EN 1443, EN 1856 and EN
1457.
The installer must observe both these and any
other local regulations.
This manual does not in any way substitute such
regulations.The product must be connected to a flue
system which ensures that the fumes produced by
combustion are exhausted in complete safety.
Before positioning the product, the installer must
check that the flue pipe is properly rated.
SMOKE CHANNEL, CHIMNEY FLUESMOKE CHANNEL, CHIMNEY FLUE
The smoke channel (pipe that connects the smoke
outlet of the fi replace with the chimney flue inlet)
and the chimney flue must, along with other legal
provisions:
• receive the discharge for a single product (multiple
product discharges are not permitted together)
• have a mainly vertical development
• no section should have a reserve slope
• have an inner section preferably circular and
however with a ratio between sides lower than 1,5
• complete the roof with the appropriate chimney
stack: direct discharge is forbidden on walls or
towards closed spaces, even if outdoors
• be created with materials with a fi re reaction class
A1 pursuant to UNI EN 13501 or similar national
standard
• be appropriately certifi ed, with an appropriate
fi replace plate, if metal
• keep the initial section
Electricity linesElectricity lines
There must be no electricity lines in theThere must be no electricity lines in the
walls or ceiling of the fi replace installationwalls or ceiling of the fi replace installation
area.area.
INSTALLATION
11


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Edilkamin Firebox Luce Plus at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Edilkamin Firebox Luce Plus in the language / languages: English as an attachment in your email.

The manual is 1.13 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Edilkamin Firebox Luce Plus

Edilkamin Firebox Luce Plus Usermanual and installation guide - English - 80 pages

Edilkamin Firebox Luce Plus User Manual - German - 28 pages

Edilkamin Firebox Luce Plus Usermanual and installation guide - German, French, Italian, Portuguese, Spanish - 80 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info