REMARKS ON INSTALLATIONREMARKS ON INSTALLATION
Note that:Note that:
• The appliance may only be installed by a qualified• The appliance may only be installed by a qualified
technician authorised to issue the declaration of technician authorised to issue the declaration of
conformity. conformity.
• The appliance must be installed and operated• The appliance must be installed and operated
in compliance with local and national law and in compliance with local and national law and
European regulations. The applicable Italian European regulations. The applicable Italian
regulation is UNI 10683. regulation is UNI 10683.
• If installed in a condominium, the appliance must• If installed in a condominium, the appliance must
be approved by the administrator. be approved by the administrator.
We give some general instructions below, howeverWe give some general instructions below, however
these do not obviate the need to comply with localthese do not obviate the need to comply with local
regulations and do not affect the installer’s liability forregulations and do not affect the installer’s liability for
the installation.the installation.
INSTALLATION
The hot air can circulate naturallyThe hot air can circulate naturally
(natural convection) or with the aid of a(natural convection) or with the aid of a
ventilation system (AIR DIFFUSER KIT)ventilation system (AIR DIFFUSER KIT)
to be purchased separately and appliedto be purchased separately and applied
BEFORE completing the installationBEFORE completing the installation
process.process.
Contact your retailer for any furtherContact your retailer for any further
information.information.
Checking the suitability of the installation
space
The room must have a volume of at least 40 m3
The appliance may not be installed in a bedroom,
bathroom or in the same room as other equipment
which draws air for combustion from the room
itself, or in any area with an explosive atmosphere.
Any extraction fans operating in the same room or
area as the product, may affect its draw.
In Italy, check the compatibility pursuant to UNI
10683 and UNI 7129 in the presence of gas fired
products.
The floor must be able to bear the weight of the
product and its accessories. If it can’t, check and
evaluate a solution.
Protection from heat and safe distances
All the surfaces of the building adjacent to the product
must be protected against heating.
The insulation measurements to implement depend on
the type of surface present.
The product must be installed in accordance with the
following safety instructions:
- minimum distance of 110 cm from flammable
materials along the sides.
- minimum distance of 13 cm from flammable materials
along the back.
- minimum distance of 20 cm from flammable materials
along the sides with glass.
- no flammable materials may be kept within 110 cm
from the front of the appliance.
10


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Edilkamin Firebox Luce Plus at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Edilkamin Firebox Luce Plus in the language / languages: English as an attachment in your email.

The manual is 1.13 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Edilkamin Firebox Luce Plus

Edilkamin Firebox Luce Plus Usermanual and installation guide - English - 80 pages

Edilkamin Firebox Luce Plus User Manual - German - 28 pages

Edilkamin Firebox Luce Plus Usermanual and installation guide - German, French, Italian, Portuguese, Spanish - 80 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info