ENGLISH
For correct use, consult the enclosed document "Firebox® Instructions for Use". If these instructions have been lost, a copy can be obtained from EdilKamin SpA.
The company is only liable for proper functioning if operated according to the documentation provided with the product.
INSTALLATION IN AN EXISTING FIRE-
PLACE FITTED WITH EXTERNAL AIR
INTAKE
(when part numbers are not speci ed, refer to the
speci cation tables on the previous pages)
N.B.: if you do not want to alter the existing
hood, the installation must be carried out
without hot-air ducting (leaving the upper
outlets closed).
In this case, the hot air only enters the room
through the slots on the front, above the door.
a) make a pit (Fig. A), in the basement of the
existing replace, big enough to hold the ex-
ternal air intake mechanism (Fig. B)
b) this pit must communicate with an ex-
ternal air inlet duct through a passage with
cross-sectional area of at least 80-200 cm²
(depending on the model)
c) position the mechanism (Fig. B) ush with
the upper face of the oor, carefully sealing
the points where outside air may leak
d) make sure the damper moves correctly
(Fig. B)
e) with a hose clamp Ø 16-20 cm t a length
of at least 2 meters of stainless steel ue, with
the tting for a Ø 16 cm ue or the tting for a
Ø 20 cm ue (Fig. C)
f) wrap the section of steel pipe with a multi-
layered ceramic bre mat or equivalent mate-
rial (Fig. C)
g) slip the section into the ue of the existing
replace and make sure the thickness of the
ceramic bre wrapping is suf cient to com-
pletely ll the space between the new steel
pipe and the existing ue (Fig. C)
h) place Firebox® onto the mechanism (Fig.
B) checking that:
- the lower ange has been removed to allow
the ow of external air;
- The de ector is open, using the knob
located at the top left on the front of Firebox®;
- a seam of high temperature mastic has
been inserted where the ue attaches and on
the smoke outlet collar;
i) lower the previously inserted stainless steel
pipe until it ts into the Firebox® smoke outlet
collar.
Do this by hand in the space between Fire-
box® and the top of the inlet to the existing
chimney
l) if Firebox® is ventilated, leave a space for
the fan power cord making sure it does not
come into contact with hot parts
m) carefully close off the remaining space
between Firebox® and the edges of the inlet
to the existing chimney.
It can be closed off with a metal mantelpiece,
brickwork or re retardant plasterboard.
Leave a slight space between the closing
material and Firebox® to allow for expansion.
INSTALLATION IN AN EXISTING FIRE-
PLACE WITHOUT EXTERNAL AIR INTAKE
Check for the possibility of making a pit inside
the existing replace (Fig. A) by removing the
re surface.
This pit must be big enough to hold the ex-
ternal air intake mechanism (Fig. A) and must
be connected to the outside by a duct with
cross-sectional area of Ø 80/200 cm2 (ac-
cording to model) (Fig. B).
If it is not possible to do as described
above, place a 80/200 cm2 external air in-
take as near to Firebox® as possible.
In this case, the mechanism is not used
and the lower Firebox ange must not be
removed.
Proceed with the installation as described in
the previous section from point "e" onwards.
INSTALLATION WITH A NEW, SPECIALLY
MADE COVERING
Position Firebox® according to the character-
istics of the new covering with which it will be
completed.
If the covering is produced by EdilKamin, you
will nd instructions for correctly positioning
Firebox® in the packaging.
Place the external air-intake mechanism
and connect the lower inlet directly with the
outside using a exible aluminium tube or a
specially made duct; Both having a minimum
cross-sectional area of 80-200 cm2 (Fig. B)
(depending on model).
Place Firebox® onto the mechanism and
make sure the lower ange has been re-
moved to allow the ow of external air (Fig.
B).
Connect Firebox to the ue with a Ø 16 or Ø
20 cm pipe.
Complete with the chosen covering and in-
stall the kits for hot-air circulation (see follow-
ing instructions).
HOT-AIR CIRCULATION AND DUCTING
(Fig. D, page 26)
The air drawn from the outside through the
special mechanism (A) is mixed with air
drawn from the room through the lower grilles
(B). The mixed air is then heated in the rear
cavity and comes out into the room through
the upper front grille (C).
This ensures replenishment of the air which
leaves Firebox® through the ue during op-
eration and at the same time heats the room.
Alternatively, the hot air may reach the room
through an outlet connected to the holes in
the upper part of Firebox® (D) with Ø 14 cm
aluminium pipes.
The air circulation described above may take
place naturally by convection or with the help
of two fans (E) housed in the base.
If the hot air is channelled into rooms other
than the one in which Firebox® is installed,
it is necessary to ensure an air return to the
installation room through grilles at the bottom
of the walls or gaps under the doors.
The pipe diameter must not be less than 14
cm so that the air does not exceed a speed
of 5 m/s, thus avoiding irritating noises or ex-
cessive load losses owing to friction.
It is important that the path of the pipes is as
straight as possible.
Aluminium pipes may be hidden within the
ceiling or false beams, or built into walls; in
any case, they must be well insulated.
The ducting must be a maximum of 4 - 5 m
long for Firebox® with natural convection and
6 - 7 m long for Firebox® with forced ventila-
tion.
This length must be reduced by 1.2 m for
each bend and for each outlet owing to load
losses.
Fig. C
The product is supplied with two anti-corro-
sion discs (one on the outside and one on
the inside of the combustion chamber). They
must be removed during unpacking and di-
sposed of as normal waste.
25


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Edilkamin Firebox Luce Plus at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Edilkamin Firebox Luce Plus in the language / languages: English, German, French, Italian, Portuguese, Spanish as an attachment in your email.

The manual is 2.51 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Edilkamin Firebox Luce Plus

Edilkamin Firebox Luce Plus User Manual - English - 24 pages

Edilkamin Firebox Luce Plus User Manual - German - 28 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info