810849
24
Zoom out
Zoom in
Previous page
1/80
Next page
- 24 -
ENGLISH
WARNINGS
Installing Firebox®
Besides the contents of this document,
please take into consideration the UNI stand-
ards:
- no. 10683 - Wood-Burning Heating Appli-
ances: Installation Requirements.
- no. 9615/90 - calculation of the inner di-
mensions of replaces.
Speci cally:
- before starting any installation operation,
it is important to check the compatibility of
the system as established by the UNI 10683
standard.
- after installation, the installer must "start-
up" the system and issue the documentation
required by the UNI 10683 standard.
Using Firebox®
Smoke damper adjustment: in the event of
dif culty clearing the smoke (low draught),
evacuation can be improved by adjusting the
screw on the damper control rod.
By turning the screw (clockwise) and closing
the door, the damper will remain slightly in-
clined, helping the smoke to ow out.
Ash tray: during operation, it must always be
completely closed; otherwise a "forge effect"
is created with consequent damage to the
Firebox® structure and covering components.
Efficiency and fuel consumption: to obtain
the declared ef ciency, it is necessary to burn
3.5 - 4 kg/h of wood (depending on the model
as shown in the technical speci cation table);
use with an excessive amount of wood may
cause damage.
When Firebox® is running at full power, it gen-
erates a signi cant amount of heat. There-
fore, during installation, carefully check that
there are no areas of contact with wood or
other combustible materials and that any
such materials are out of range of the heat
which radiates from the replace.
There should be insulation between Firebox®
and these materials or a gap of at least 3 cm
with free air ow, to prevent excessive heat
build-up.
Special front protection panels are available
for beams on request.
Electrical connections
(for forced ventilation versions)
- These must conform to professional installa-
tion and construction standards.
- The electrical components are always live;
before any maintenance, disconnect the plug
and turn off the electrical panel of the dwell-
ing.
- Avoid contact between electrical wires, Fire-
box® and the ue.
- The electrical equipment supplied with Fire-
box® must not be tampered with in any way.
For further details, con-
sult the following document:
“Firebox® Instructions for use" attached to the
product.
EXTERNAL AIR INTAKE (Figs. A-B)
The connection with the outside, made with
a cross-sectional area of at least 80/200 cm²
(depending on the model) is absolutely es-
sential, as prescribed by the standard gov-
erning installation requirements (UNI 10683).
It must, therefore, be provided.
It is made with a duct that must bring outside
air directly to the adjustment mechanism
(Fig. B). The regulation mechanism must be
attached to the bottom of Firebox®.
During installation, carefully seal the points
where the external air may leak.
The external air duct may come from behind,
from below, from the side, or consist of a ex-
ible hose which runs directly from the outside
to the mechanism vent (Fig. B).
It is advisable to apply a protection grille on
the outside of the air-intake duct that does
not, reduce the air- ow capacity.
The external air must be drawn in at oor
level.
If it is not possible to do as described above,
place the external air intake as near to Fire-
box® as possible.
SUPPORT STAND
UNIVERSAL OPTION (Fig. L)
Screw the 2 frame-fastening brackets (A) to
the bottom of the Firebox® structure, using
the ø 3.6 holes and the six 4.8x13 screws
provided.
At the pre-cuts, cut the vertical tubes of the
support frame (B) to the desired height for
positioning Firebox®.
Using the pins provided, t the frame (B) to
the brackets (A) previously fastened to Fire-
box®.
Take care that the horizontal projections (C)
of the frame are on the rear facing the wall.
Lock the support stand with the four 8x40
screws provided.
Position Firebox® with stand and fasten to
the oor using the anchors and 8x70 screws
provided.
FLUES (Fig. N)
The Firebox® smoke outlet has a circular
cross-section. It is provided to allow the use
with EdilKamin stainless steel pipes (rigid sin-
gle-wall or insulated rigid double-wall), that
allow a quick, secure connection to the ue.
If the ue inlet is not
vertical in relation to the
replace, the connection between the re-
place and ue must not narrow or slope by
more than 45° (1-3).
In the case of old or oversized ues, it is
advisable to line them with stainless steel
pipes of a suitable diameter and with suit-
able insulation. For ues located outside, we
recommend using the stainless In the case of
outdoor ues, it is advisable to use insulated
double-wall stainless steel pipes.
The constructional features, in particular as
regards mechanical strength, insulation and
gas-tightness, must be able to withstand a
smoke temperature of at least 450 °C.
Use high temperature mastic to seal where
the steel pipe connects to the Firebox®
smoke outlet.
Using the rigid, stainless steel ue requires a
female-female tting on the smoke outlet of
the replace.
The chimney pot should be placed in full wind.
FIREBOX® Installation Instructions
Fig. N
Fig. A
Fig. B
AA
BB BB
C
C
Fig. L
24


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Edilkamin Firebox Deco at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Edilkamin Firebox Deco in the language / languages: English, German, French, Italian, Portuguese, Spanish as an attachment in your email.

The manual is 2.51 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Edilkamin Firebox Deco

Edilkamin Firebox Deco User Manual - English - 24 pages

Edilkamin Firebox Deco User Manual - German - 28 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info