ENGLISH
INSTALLATION
INSTALLER
The infiltration of condensation water
through the chimney is to be avoided at
all costs. An anti-condensation ring must
be fitted where necessary (please contact
your chimney sweeper). Damages caused
by condensation water are not included in
warranty.
REMARKS ON INSTALLATION
REMARKS ON INSTALLATION
Note that:
Note that:
installation must be carried out by authorised
installation must be carried out by authorised
technical personnel;
technical personnel;
the appliance must be installed and operated
the appliance must be installed and operated
in compliance with local and national law and
in compliance with local and national law and
European regulations. The applicable Italian
European regulations. The applicable Italian
regulation is UNI 10683;
regulation is UNI 10683;
if installed in a condominium, the appliance must
if installed in a condominium, the appliance must
be approved by the administrator.
be approved by the administrator.
Here are a few general instructions, although these do
Here are a few general instructions, although these do
not obviate the need to comply with local regulations
not obviate the need to comply with local regulations
and do not affect the installer's liability for the
and do not affect the installer's liability for the
installation.
installation.
Checking the suitability of the installation
space
The room must have a volume of at least 15 m3
The floor must be able to bear the weight of the
product and its accessories.
Level the product (the product is provided with
adjustable feet).
The appliance cannot be installed in the same
room as other equipment which draws air for
combustion from the room itself or any area with
an explosive atmosphere. Any extraction fans
operating in the same room or area as the product
may affect its draught.
In Italy, check the compatibility pursuant to UNI
10683 and UNI 7129 in the presence of gas-fired
products.
Protection from heat and safety
clearances.
The surfaces of the building adjacent to the product
must be protected against overheating.
The insulation to be used will depend on the type of
surface in question.
The appliance must be installed in accordance with
the following safety instructions:
- no flammable materials may be kept less than 5 cm
to the sides.
- no flammable materials may be kept within 80 cm
from the front of the appliance.
If connected to a wooden or otherwise flammable
wall, the smoke exhaust pipe must be insulated
appropriately.
If installed on flammable or combustible floors, or
floors not able to withstand its load, place steel or
glass plates beneath the stove to distribute the load.
Information on the product’s positioning
The product is designed to operate in all climate
conditions. In special circumstances, such as strong
wind, the safety devices may intervene to switch the
appliance off.
Contact the authorised Edilkamin Technical Assistance
Centre.
45


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Edilkamin Blade H 15 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Edilkamin Blade H 15 in the language / languages: English as an attachment in your email.

The manual is 4.2 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Edilkamin Blade H 15

Edilkamin Blade H 15 Usermanual and installation guide - German - 88 pages

Edilkamin Blade H 15 Usermanual and installation guide - French - 88 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info