810884
21
Zoom out
Zoom in
Previous page
1/36
Next page
21
ENGLISH
Screw feeder filling
The product is supplied with an empty tank and the
connection to the empty pellet furnace. During the first
ignition, the technician fills it by pressing the +/- keys
at the same time (from the remote control/panel) for a
few seconds; once the keys are released “Ricarica”
appears on the display.
It is normal for there to be a residual amount of pellets
in the tank that the screw feeder cannot suck up.
USER INSTRUCTIONS
Control panel with display (figure below)
Six buttons
to switch on and off (press and hold for 2”) and to
leave the menu during programming
to display the menu during programming
to regulate upwards
to regulate downwards
pellet load/reserve button: when pressed once,
“informs” the boiler memory that a 15 kg bag of
pellets has been loaded, so you can keep a count
of the reserve
(boiler setting button: allows you to manage a
secondary circuit, e.g. for a boiler, via the +/- keys
Display views
On the left side appear the various operating modes
(power, temperature, etc.)
On the right side is displayed the time left until the next
automatic cleaning of the turbulators
INTERFACE
The boiler can be managed in the same way:
from the display on the boiler;
by remote control
Fig.10
Display left LH Display Right RH
Load pellets/reserve Boiler
OPERATION
Mode Programmable
sizes
AUTOMATIC desired water delivery
temperature
CLIMA COMFORT desired room tem-
perature
TIMER ON/OFF schedule on
different days of the
week
The technician can enable an "extension" of Auto-
matic mode (Econom), which switches off the boiler
when the water reaches the set delivery temperature.
The technician must make this choice according to
the type of system.
OPTIONAL CONNECTIONS
The technician can supply, on request:
external thermostat, telephone dialler for connection to
the external serial port
21


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Edilkamin ATLANTA UP at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Edilkamin ATLANTA UP in the language / languages: English as an attachment in your email.

The manual is 4.91 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Edilkamin ATLANTA UP

Edilkamin ATLANTA UP Usermanual and installation guide - German - 36 pages

Edilkamin ATLANTA UP Usermanual and installation guide - Dutch - 36 pages

Edilkamin ATLANTA UP Usermanual and installation guide - French, Italian - 68 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info