EN
Inverter technology
The compressor and circulation pumps with modulating inverter technology can adapt the thermal power, flow and outlet
temperature to any given needs. On the other hand, the starting cycles are considerably reduced, prolonging equipment service life.
All this allows users to reduce installation electrical consumption and obtain optimum energy efficiency throughout the year.
HTR technology
High temperature recovery (HTR) system. This heat exchanger is used to raise the DHW storage tank temperature to 70ºC when the
heat pump is producing heat or cool air for the home. This technology increases the performance of the heat pump and its energy
efficiency, since it reduces the time dedicated to the production of DHW.
Auxiliary integrated hot water equipment
Electrical resistor in the production circuit. This resistor can be used at specific times to cover consumption peaks, achieve high DHW
temperatures or act as an emergency unit if the compressor cannot be started up.
Passive cooling technology
The installation can also include an additional exchanger for passive cooling. This exchanger transfers heat directly from the
production circuit to the brine circuit without having to use the compressor. The only electrical consumption is by the circulation
pumps, thereby obtaining high energy efficiency. This technology allows economic home cooling with moderate outdoor
temperatures.
Active cooling technology by cycle inversion
Reversible heat pumps can reverse the operation cycle in the summer to produce active cooling. Thus, the heat pump transports
energy from the home to the terrain by using the compressor. This technology can be used to cool the home even in the presence of
high outdoor temperatures.
Simultaneous production
The heat pump can produce heat and cold simultaneously, it controls the emission temperature for both services by managing the
heat pump and modulating derivation valves.
Comprehensive design
Ecoforest heat pumps include most of the components needed for the installation or heating / cooling and DHW. This simplifies
external installation, reducing costs and space.
Options
ecoAIR
ecoGEO
ecoGEO
Reversible
ecoGEO HP
ecoGEO HP
Reversible
Active cooling technology by cycle inversion
Simultaneous production
Passive cooling technology (internal heating exchanger)
Passive cooling technology (external heating exchanger)
Auxiliary integrated hot water equipment
HTR technology
Table 2.1. Available options in Ecoforest product range.
36


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Ecoforest ecoTHERMO 200 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Ecoforest ecoTHERMO 200 in the language / languages: English, German, Dutch, Danish, French, Italian, Polish, Portuguese, Swedish, Spanish as an attachment in your email.

The manual is 9.07 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info