2.1. Heat pumps
Ecoforest heat pumps are comprised by three main circuits: source circuit, cooling circuit and output circuit. These circuits transport
the thermal energy between the source and the various points of consumption (DHW, heating, etc.). The transfer of energy from one
circuit to another takes place through heat exchangers, where the higher temperature fluid transfers heat to the fluid at a lower
temperature without mixing. The temperature of the source circuit is lower than required for production. Therefore, to transfer the
energy between both circuits, the refrigerant undergoes a thermodynamic cycle during which it evaporates at low pressure and
temperature and condenses at high pressure and temperature, repeatedly. To carry out this process, the compressor consumes a
small amount of electric energy compared to the thermal energy that it supplies. In geothermal heat pumps the source is obtained
from the ground, while in aerothermal sources it is obtained from outside air.
Figure 2.1. Operation of a geothermal heat pump in normal conditions.
Figure 2.2. Operation of an aerothermal heat pump in normal conditions.
The Ecoforest heat pumps include the most advanced technologies to produce heat, cool air and DHW for your home economically
and respecting the environment.
Free energy extracted from the earth
75 - 80%
Energy supplied
100%
Electric energy consumed
20 - 25%
Free energy extracted from the outside
air
75%
Energy supplied
100%
Electric energy consumed
25%
35


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Ecoforest ecoTHERMO 200 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Ecoforest ecoTHERMO 200 in the language / languages: English, German, Dutch, Danish, French, Italian, Polish, Portuguese, Swedish, Spanish as an attachment in your email.

The manual is 9.07 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info