A025
Minimum temperature in “temperature 1 probe”,
used to monitor the sanitary hot water tank.
Installation of boiler badly measured.
Boiler working to low levels of power.
Disconnected NTC.
NTC badly placed.
A026
Maximum temperature in “temperature 1
probe”, used to monitor the hot sanitary water
tank.
Air in the circuit.
Little dissipation of the energy generated.
Too heavily used.
Shortcut in NTC.
A027
Minimum temperature in “temperature 2 probe”,
used to monitor the hot sanitary water tank.
Installation of boiler badly measured.
Boiler working to low levels of power.
Disconnected NTC.
NTC badly placed.
A028
Maximum temperature in “temperature 2
probe”, used to monitor the hot sanitary water
tank.
Air in the circuit.
Little dissipation of the energy generated.
Too heavily used.
Shortcut in NTC.
A029
Minimum temperature in “temperature 1 probe”,
used to monitor the buffer tank.
Installation of boiler badly measured.
Boiler working to low levels of power.
Disconnected NTC.
NTC badly placed.
A030
Maximum temperature in “temperature 1
probe”, used to monitor the buffer tank.
Air in the circuit.
Little dissipation of the energy generated.
Too heavily used.
Shortcut in NTC.
A031
Minimum temperature in “temperature 2 probe”,
used to monitor the buffer tank.
Installation of boiler badly measured.
Boiler working to low levels of power.
Disconnected NTC.
NTC badly placed.
A032
Maximum temperature in “temperature 2
probe”, used to monitor the buffer tank.
Air in the circuit.
Little dissipation of the energy generated.
Too heavily used.
Shortcut in NTC.
A033
Burning pot open during cleaning phase.
Burning pot base poorly closed.
Sensor dirty or broken.
Engine broken.
Cable or connector disconnected
A034
Burning pot open during hardware test.
Open or badly closed basket base.
Sensor dirty or broken.
Engine broken.
Cable or connector disconnected.
A035
Burning pot open during operation.
Open or badly closed burning pot base.
Sensor dirty or broken.
Engine broken.
Wiring or connector disconnected or loose.
A036
Ashtray drawer open during hardware test.
Full ashtray drawer, perform maintenance.
Defective sensor.
Defective Periphery.
Wiring or connector disconnected or loose.
A037
Ashtray drawer open during operation.
Ashtray drawer full, perform maintenance.
Defective sensor.
Defective Periphery.
Wiring or connector disconnected or loose.
A038
Ashtray drawer open during operation (machine
off).
Full ashtray drawer, perform maintenance.
Defective sensor.
Defective Periphery.
Wiring or connector disconnected or loose.
65


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Ecoforest Cantina Super at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Ecoforest Cantina Super in the language / languages: English, German, Dutch, French, Italian, Portuguese, Spanish as an attachment in your email.

The manual is 19.61 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Ecoforest Cantina Super

Ecoforest Cantina Super Installation Guide - English, French, Italian, Portuguese, Spanish - 136 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info