INSTALLATION
Proper operation of the water heater requires air for combustion and ventilation. Provisions
for combustion and ventilation air must comply with referenced codes and standards.
Combustion and Ventilation Air
0.29 KW of the aggregate input of all appliances within that space.
The air must be supplied through two permanent openings of equal area.
be located within 12”(30.4cm) below the ceiling.
The minimum net free area of each opening must not be less than one
square inch per 0.29 KW of the total input rating of all the appliances in
the enclosure (but not less than 100 square inches(254cm), if each opening
Buildings of unusually tight construction shall have the combustion and
ventilation air supplied from outdoors, or a freely ventilated attic or crawl
space. If air is supplied from outdoors, directly or through vertical ducts,
a minimum net free area of not less than one square inch(2.5cm) per 1.17
KW of the total input rating of all the appliances in the enclosure.
If horizontal ducts are used to communicate with the outdoors, each
opening must have a minimum net free area of not less than one square
inch(2.5cm) per 0.59 KW of the total input rating of all the appliances in the
enclosure. If ducts are used, the minimum dimensions of rectangular air
ducts shall not be less than 4”(10.1cm).
Included Parts
Verify all included parts are present (see below).
ventilation air must be made.
NOTICE: If the duct openings which supply combustion and ventilation air are to be covered with a
protective screen or grill, the net free area (openings in the material) of the covering material must be
used in determining the size of openings. Protective screening for the openings MUST NOT be smaller
than ¼”(.63cm) to prevent clogging by lint or other debris.
Typical Installation
Recommended Not Included Parts
These items are not included but are recommended and available for purchase at eu.eccotemp.com
¾”(1.9cm)Threaded
Tee Fitting ¾”(1.9cm) Pressure Relief Valve
11


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Eccotemp SH12 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Eccotemp SH12 in the language / languages: English as an attachment in your email.

The manual is 4.53 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Eccotemp SH12

Eccotemp SH12 User Manual - German - 39 pages

Eccotemp SH12 User Manual - Dutch - 39 pages

Eccotemp SH12 User Manual - French - 39 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info