OPERATION INSTRUCTIONS
1. Turn on the circuit breaker to bring electrical power to the unit.
2. Open water faucet for a few minutes until water ow is continuous and all air is purged from water pipes. The
unit must be operated after the breakers are turned on.
3. After the unit is supplied with power, a beep sound can be heard and LED lights for 2 seconds, no other
display, the appliance keeps standby.
4. Touch to turn ON/OFF the water heater. When the unit is ON, LED displays actual water temperature
of the outlet. When the water heater is not operating, the screen will switch to the screen saver after 15
seconds. The display screen light will be off. Touch the screen, it will return to operating mode.
Touch and to adjust the outlet temperature. Temperature setting range is 86-127°F.
If the unit has been paused, You may initially get a short burst of very hot water while you turn on again.
Please run the water through for a few seconds to let the temperature settle down. Please check hot
water with hand before using hot water.
If the unit will not be used in winter, drain out water completely so that the heater will not FREEZE.
Please periodically clean inlet strainer and the shower to keep a free water ow.
5. Touch and hold on for 5 seconds to lock the operation keys and the will light in the display screen.
All the operational keys can not function.
Touch key and hold on for 5 seconds to lift the temperature lock and the will disappear in the display
screen. The operational keys can function right now.
6. The real time water ow (GPM) displays in the screen when there is water ow through the water heater.
7. There is a automatic memory function to avoid repetitive operation, while you turn on the appliance, the
default set temperature will be the same as last time it was set.
4.
TROUBLE-SHOOTING
Problems Possible Causes Corrective Actions
1. Inlet and outlet ttings leaking A. Fittings are not tight
B. Rubber washer worn-out
A. Tighten ttings.
B. Change rubber washer.
2. No LED signal A. Power not connected.
B. LED damaged.
A. Connect power to the unit.
B. Change LED.
3. Functional keys not working A. No water out from shower.
B. Water pressure too low.
C. Key or PCB damaged.
A. Open valve to get water.
B. Open valve to get pressure.
C. Change key or PCB.
4. Water too hot A. Too high temperature set.
B. Water ow too little.
A. Set a lower temperature.
B. Open valve more.
5. Water too cold A. Low temperature set.
B. Water ow too much.
A. Set a higher temperature.
B. Reduce water ow.
6. Reduced outlet water pressure Inlet strainer or shower clogged. Clean strainer and shower.
7. LED displays E1 Outlet temperature is over 67°F/153°F A, Reduce the temperature
B, Turn up the water ow
8. LED displays E3 Temperature sensor failure Please contact with your local dealer
9. Display overload Inlet water ow is too high. Reduce the inlet water ow
7 and 8 should only be performed by qualified electrician. The person who initially installed the unit is the best one to contact for help.
Error Code Error Description Possible Cause What to Do
E1 Overheating Thermal
Cut-off
The unit has reached a tempe-
rature of 153F/67C
Check the reset buttons on heating elements. Possible
Triac failure. Contact Technical Support for help.
E3 Sensor Malfunction The temperature sensor has
stopped working
Outlet Temperature sensor failure. Contact Technical
Support.
E4 Dry-heating thermal
cut-off.
In case of dry heating, the
unit’s electricity will be cut off
Possible Flow Meter sensor failure. Contact Technical
Support.
A03 Sensor Malfunction or
Power Board Failure
Power Board failure Possible Power Board Failure. Contact Technical
Support.
15


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Eccotemp iE series at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Eccotemp iE series in the language / languages: English as an attachment in your email.

The manual is 3.58 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info