INSTALLATION
STEP 1. Remove shipping plugs from pump ports. Some water from factory testing may spill out.
STEP 2. Connect ttings supplied with the pump to your hoses. If using the slip-on barb
connections use hose clamps.
STEP 3. Mount pump horizontally or vertically. Read mounting instructions below.
STEP 4. Install inlet and outlet port connectors. Do not overtighten.
STEP 5. Install the strainer in an accessible location between the tank and pump inlet. This
strainer or equivalent is recommended.
MOUTING
(Please read before completing steps)
The pump can be at the same level or below the water tank. It may be positioned above the
water tank if needed, as it is capable of a 6ft. (1.8m) vertical prime. Horizontal inlet tubing will
allow priming to 30ft (9m)
Consider a dry location that allows easy access if maintenance is required. The pump should
not be located in an area of less than one cubic foot unless adequate ventilation is provided.
Excessive heat may trigger the integral thermal breaker and interrupt operation. When the
temperature drops the breaker will automatically reset and start proration.
The pump can be mounted horizontally or vertically. If mounting of the pump vertically, the
pump head should be in the down position.
The mounting feet are intended to isolate the pump from the mounting surface; over-
tightening, attening, or use of oversized screws will reduce the ability to isolate vibration
and noise through the lines.
INSTALLATION INSTRUCTIONS
Solid surface
Accessible location away from living quarters
Properly sized wiring
Proper electrical protection
Strainer on plumbing elbows and valves near the pump
Minimize ow restrictions in the system
WIRING
STEP 1. Use 14 gauge stranded wire to 20’, 12 gauge to 50’ from power source.
STEP 2. Use a 10-15 amp rated on-o switch on the (+) (red) motor lead
STEP 3. Install a 10 amp fuse protection on the positive lead.
ELECTRICAL
(Please read before completing steps)
The pump should be on a dedicated (individual) circuit protected by the specied fuse
indicated on the motor label.
A U/L, CE etc. approved marine duty (ignition protected) switch rated at above 15 amps is
recommended and must interrupt current ow on the positive (+ red) lead.
The pump must be grounded to a known ground (battery). The ground wire must be the
same size (gauge/Mm2) as the positive wire.
Wire sizing: Proper wire sizing is required for good pump operation. If the wire is too small,
low voltage will aect the pump performance and can create re hazard.
The total current draw on the circuit must not exceed 15 amps. If the pump is used in
conjunction with other components, overload current protection (fuse or circuit breaker) and
wire size must be for the total amp requirements of all devices on the circuit.
4


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Eccotemp EccoFlo at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Eccotemp EccoFlo in the language / languages: English as an attachment in your email.

The manual is 5.89 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Eccotemp EccoFlo

Eccotemp EccoFlo User Manual - German - 10 pages

Eccotemp EccoFlo User Manual - Dutch - 10 pages

Eccotemp EccoFlo User Manual - French - 10 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info