When installing a T-piece, always keep to
the mounting positions shown in the drawing.
When connecting fuel pipes to a fuel hose, always
mount the fuel pipes abutting (see drawing).
ATTENTION!
Fuel supply line from the tank fitting to the conveying pump.
Dosing pump: should be installed in the vicinity of the tank.
T-piece.
Fuel filter only required in connection with polluted fuel;
supply / run-off must always be vertical.
Fuel hose, 5 x 3 (inside diam. = 5 mm).
Fuel pipe, 4 x 1 or 6 x 2 (inside diam. 2 mm).
Fuel pipe, 4 x 1.25 (inside diam. = 1.5 mm).
Transition piece Order No. 25 1888 80 01 02; Fuel hose, 5 x 3
(inside diam. 5 mm), approx. 50 mm long with fuel pipe, 6 x 2.
Fuel hose, 3.5 x 3 (inside diam. 3.5 mm), approx. 50 mm long.
Permissible line lengths
Suction side
A = max. 5 m
Pressure side
B = max. 6 m
With suction line,
inside diam. 2 mm, Pos. 6
B = max. 10 m
With suction line,
inside diam. 5 mm, Pos. 5
correct
incorrect
flow direction
from the fuel tank
to the vehicle engine
Tapping fuel with the T-piece from the fuel
supply line
Precondition:
Fuel lines must be tight.
A maximum preliminary pressure of 0.2 bar can
arise in the fuel lines in any operating mode.
Visit www.butlertechnik.com for more technical information and downloads.
www.butlertechnik.com
15


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Eberspacher AIRTRONIC D4 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Eberspacher AIRTRONIC D4 in the language / languages: English as an attachment in your email.

The manual is 2,99 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Eberspacher AIRTRONIC D4

Eberspacher AIRTRONIC D4 Usermanual and installation guide - Dutch - 37 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info