11. ACCESSORIES
Further accessories can be found on our homepage on www.easyalarm.ch.
11.1Motion / Presence detector-PIR-RJ45 (Plug&Protect)
11.1.1 Preliminary considerations
Choose the mounting location after careful consideration of the area to be protected.
The motion detector should be located so that an intruder will cross the infrared beam
pattern. If used to verify presence, a regular used room should be detected. Figure
shows the different infrared beam patterns at a typical mounting height of 2.5m.
Notes:
Do not mount detector towards direct sunlight or near to heat sources.
Do not mount detector behind items like glass or curtains because the infrared-
beam cannot penetrate them.
Keep away pets like cats or dogs from the protected area.
Do not protect the same area by more then one detector, because they can interfere.
11.1.2 Installation
Connect the cable of the motion detector on the EXT port of the alarm unit. The AC adapter of the alarm unit provides the
power supply of the detector
11.1.3 Activation
Provided the motion detector is plugged in, EasyAlar detects the motion detector during the switching on procedure.
Important notes:
By disconnecting the motion detector during the operation mode, an alarm is
triggered followed by the announcement: ”alarm due to sensor 1, sensor
failure!”
By connecting the motion detector after the start up procedure of the alarm unit,
an alarm is triggered followed by the announcement: “alarm due to sensor 1,
sensor 1 activated!
11.1.4 Deactivation
If the motion detector is not plugged in, EasyAlarm® automatically deactivates the
supervision of the motion detector.
11.1.5 Specification
Supply voltage 9..16 VDC (through AC-adapter)
Dimension 107 x 58 x 39 mm (L x W x D) without swivel
Weight 75 g
Cable length 8m (RJ45)
Detection type passive infrared (PIR)
Alarm contact normally closed
11.1.6 Adjustment
Safety note:
Before you open cover please check, that the telephone cord is DISONNECTED.
Otherwise you can get in contact with the telecommunication voltage!
Remove the front cover by twisting a flat screwdriver in the slot between the cover and
the base at the bottom of the motion detector
11.1.6.1 Pulse count
You can set PULSE jumper at position 1,2 or 3 corresponding to the desired pulse count before an alarm will be triggered.
Default = 2.
11.1.6.2 WALK-test
To disable LED indication, remove the LED jumper and place it on one pin only. To activate LED indication, place LED
jumper over both pins.
11.1.6.2.1 Mounting height
If motion detector is not mounted at 2.5m you can adjust like this:
5. Loosen the PC-Board holding screw. Slide the PC-Board so that the plastic
pointer on the right side is positioned at the appropriate scale position.
For higher than 2.5m => Slide PC-Board up
For lower than 2.5m => Slide PC-Board down
6. Tighten the PC-Board holding screw
7. Mount front cover
8. Walk through the entire protected area and observe the LED to ensure full
coverage
Mounting screw
28


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for EasyAlarm CONTROL at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of EasyAlarm CONTROL in the language / languages: English as an attachment in your email.

The manual is 0,98 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of EasyAlarm CONTROL

EasyAlarm CONTROL User Manual - German - 32 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info