761230
15
Zoom out
Zoom in
Previous page
1/64
Next page
15
L N
6mm
L N
6mm
3.1
Rear cable entry.
4 5
Connecting to terminal block. Attaching main body.
Warning: Risk of electric shock!
Ensure power is not connected.
1. Ensure the cable does not sit above
the cable guide from the cable inlet
to the terminal block. If the cable
sits above the guide walls it may
interfere with main components,
prevent the security screws being
fitted correctly, or risk the main body
being forced on to the backplate,
causing damage.
2. Unscrew the cable clamp from
the backplate. Remove the cable
terminal block.
3. Open the flap on the terminal
block. Secure the live, neutral and
earth wires into the correct terminal
locations as indicated on the
terminal block casing.
4. Verify the connections are correct
before proceeding.
5. Close the flap on the terminal block
and fit it into the backplate.
6. Screw in and secure the cable clamp.
CAUTION: DO NOT OVERTIGHTEN
AND CRUSH THE POWER CABLE.
CAUTION: Do not overtighten screws.
1. Hook the main body of the unit over
the top rim of the backplate.
2. Swing the main body of the unit
down on to the back plate. (For
installations with the cable entry on
the side, ensure that the side bracket
seal is correctly seated against the
main body.)
3. Insert and tighten the (2) security
screws into the side of the main body
with the service tool as illustrated.
Recommended torque of 0.5-
0.7NM.
4. Turn power on.
5. Test unit for correct operation.
IMPORTANT
DO NOT USE SEALANT WHEN
FIXING THE UNIT TO THE WALL.
DO NOT PAINT/COAT THE MAIN
BODY OR PLACE GRAPHICAL
STICKERS ON IT OR THIS MAY
DAMAGE THE ANTI-BACTERIAL
SURFACE.
IF A CLEANING PRODUCT IS LEFT
ON THE MACHINE FOR TOO LONG,
A FILM WILL FORM. THIS MAY
REDUCE THE EFFECTIVENESS OF THE
ANTI-BACTERIAL SURFACES.
electricity supply cable from the wall
must align with rear cable entry point
in the backplate.
4. Mark the location on the wall with a
pencil. Use the backplate to mark the
locations for the four fixing points.
5. Drill holes.
6. Fix the optional back panel if
required.
Fixing the backplate to the wall.
Fit the backplate securely to the wall
using the appropriate fixings for the
wall type and weight of the unit. Do
not use counter-sunk screws.
Do not secure tightly until after the
power cable has been secured.
Installing the power cable.
1. Cut the entry hole in the rubber
cable grommet to the correct size:
leave a hole smaller than the
diameter of the power cable to
ensure the cable fits tightly.
2. Pull the cable through the
grommet. Ensure the cable is long
enough to route correctly through
the backplate to the terminal
block.
The cable must sit in the
dedicated channel.
3. Fit the grommet into the
backplate. Ensure it is secure.
4. Secure the screws in the
backplate.
5. Proceed with step 4, ‘Connecting
to terminal’.
6mm
● Primary fixing locations (x4).
Do not use countersunk screws.
Secondary fixing locations.
15


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Dyson AB12 - Airblade V at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Dyson AB12 - Airblade V in the language / languages: All languages as an attachment in your email.

The manual is 19,46 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Dyson AB12 - Airblade V

Dyson AB12 - Airblade V Additional guide - English - 1 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info