Operating Instructions 971 Version 00.0 - 03/2014
25
5.3 Adjusting the thread tensions
The thread tension of the needle thread should be tighter than that
of the looper thread. Overly tight thread tensions cause the material
to be pulled together.
Overly loose looper thread tensions can cause missed stitches.
5.4 Removing a thread break
Fig. 11: Thread break
On the sewing head there are two thread monitors, whose switching
flags are released, if the needle or looper thread is torn. In this case, the
automatic sequence is stopped and the LEDs on the sewing head indicate
whether it is the needle or looper thread that is torn.
To remove a thread break:
1. Bring the needle bar into the top position by turning the hand wheel.
2. Swing the sewing head out. For this purpose, pull the magnetic roller
downwards, 5.7.1 Swinging the sewing head in and out, pg. 31.
3. Thread the thread, 5.2 Threading the looper thread, pg. 24.
(1) - Throat plate insert
Caution: Risk of injury!
Switch off the main switch before threading.
WARNING
27


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Durkopp Adler 971-01 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Durkopp Adler 971-01 in the language / languages: English as an attachment in your email.

The manual is 3,59 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Durkopp Adler 971-01

Durkopp Adler 971-01 User Manual - German - 56 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info