6 Assembly of the control
Attention!
The control must not stand on the floor because otherwise the
ventilation grid are covered. This can lead to the overheating of the
control.
–
Screw the control on the underside of the table top with the
screws 2 and 3. The side carrying the data plate 9 points to the
front.
–
Connect all plugs in field 1 and 4 with the respective bushes. The
plugs are clearly marked with an imprint on cable 8 and the
bushes at the casing 7! Cable and bush have the same
designation and symbol. Check whether every plug is in the
correct bush !
–
Screw plugs and bushes together.
–
Finally screw the protective bracket 5 under the table top so that
the cables cannot be ripped out or damaged inadvertently. In
addition secure the protective bracket by screwing it together
with the control using the screws 10.
6
19 4 5
827 3
78
X20 X30 X40 X50