613310
17
Zoom out
Zoom in
Previous page
1/35
Next page
13
Symbol P Automatic revolutions ON
Symbol Q Left needle disconnected
The arrows on the display indicate switching the functions
which are displayed by symbols above the pushbuttons on.
7.2.2.1 Adjustment by means of buttons with fixed setting
function
Note: It is important to finish the seam in order to reach
effective button pressing (press the treadle fully backwards
down).
Setting start bar:
Drive enables sewing start bar automatically. It is necessary to
choose the type (single, double, off) and number of stitches
which will be sewn forwards and backwards.
The arrow above its symbol shows the type of bar (chosen by
gradually pressing pushbutton 1). It will be displayed
following after pressing pushbutton 1.
Arv (SAv) XXX - number of stitches of start (fancy) bar for-
wards or
Arr (SAr) XXX - number of stitches of start (fancy) bar back-
wards for about 3 sec.
At this time you can change the number of stitches by gra-
dually pressing the pushbutton + or -.
Setting end bar:
The same applies to the start bar (setting by the means of
pushbutton 4).
Erv (SEv) XXX - end (fancy) bar number of stitches forwards
Err (SEr) XXX - end (fancy) bar number of stitches backwards
Note: The last section of end bar must have at least 3 stitches.
Foot position adjustment by stopping at the seam (by neutral
position of treadle) and after finishing seam (by neutral posi-
tion of treadle):
Setting is by means of pushbutton 6, arrow indication above
the corresponding symbol.
Needle position adjustment by stopping at the seam:
Setting is by means of pushbutton 7.
Trimming switched ON/OFF:
To be set using pushbutton 5.
Sewing programme ON:
To be switched on using pushbutton 0.
Switching ON/OFF the function of the pushbutton F:
The pushbutton F on panel can have assigned one of the
following functions: Sst - softstart
SrS - fancy bar
Frd - reverse angle after trimming
7.2.2.2 Setting by means of parameters
Drive memory contains the parameters which enables sewing
system tuning. These parameters have exact meaning and
they are divided into 3 levels. Further parameters which are
available only for operation will be quoted. Each parameter
has its (sequence) number and value.
General procedure by changing parameters of operation level:
- switch the main switch on or finish the seam by pressing the
treadle fully backwards down
- press pushbutton P on the panel V 820
- on the display there is no data shown
- by depressing the pushbutton E several times, set the
required parameter (without having displayed the parameter
number)
- you can change the value using pushbuttons + or -
- by depressing the pushbutton E you will pass in the given
sequence to the following parameter
- by depressing the pushbutton P down you will leave the
mode of changing parameters
AB
CD E F GHI JKLMNOPQ
17


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Durkopp Adler 4280i - 6 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Durkopp Adler 4280i - 6 in the language / languages: English as an attachment in your email.

The manual is 1,9 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Durkopp Adler 4280i - 6

Durkopp Adler 4280i - 6 User Manual - German - 35 pages

Durkopp Adler 4280i - 6 User Manual - French - 35 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info