810223
7
Zoom out
Zoom in
Previous page
1/16
Next page
7
ENGLISH
L2000631 Installation guide for DucoBox Focus (Revision N | 19.10.2023)
04.B Pairing the control valves
The control valves are paired automatically to the DucoBox whenever ‘installer mode’ is activated (see “Pairing components”
chapter)�
04.C Removing / replacing control valves
Taking control valve out temporarily
Follow these steps to take a control valve out of the unit
temporarily, e�g� to clean it during maintenance� Make sure
that the control valve is inserted back in the same location� Use
the letter labels on the DucoBox and the relevant valve for this�
The DucoBox will retain all its settings when the control valve
is reconnected�
Temporarily removing control valve
1Briefly press the button on the valve to close it
for 15 minutes� The LED will go out�
2Disconnect the wiring�
3Slide the valve out of the DucoBox�
Permanently removing or replacing control valve
To remove a control valve permanently from the system or to replace it (e�g� in the event of a fault) it is important that it should be
deregistered correctly� The DucoBox will not be able to be calibrated correctly if this is not done�
Permanently removing control valve
1Briefly press the button on the valve to drive it shut�
2
Activate ‘Installer mode’ by pressing ‘INST’ on the
DucoBox� The LEDs on the DucoBox and control
valves will flash green rapidly
3
Long-press the button once on the control valve to
be removed in order to remove it from the network�
ATTENTION: any underlying components will also
be removed from the network.
4Disconnect the wiring from the control valve to be
removed and slide it out of the DucoBox�
5Deactivate ‘Installer mode’ by pressing ‘INST’ on the
DucoBox� All LEDs will stop flashing�
Replacing a control valve
1Briefly press the button on the valve to drive it shut�
2
Activate ‘Installer mode’ by pressing ‘INST’ on the
DucoBox� The LEDs on the DucoBox and control
valves will flash green rapidly
3Short-press the button twice on the control valve to
be replaced in order to remove it from the network�
4Disconnect the wiring from the control valve to be
replaced and slide it out of the DucoBox�
5Slide the new control valve into the DucoBox and
connect it�
6
Short-press the button on the new control
valve once� The latter will take on all settings /
connections in the network�
7Deactivate ‘Installer mode’ by pressing ‘INST’ on the
DucoBox� All LEDs will stop flashing�
04.D LED indications
In normal operation, the LED on the control valves will be white
or off, depending on the control valve position� The brightness
of the LED indicates the flow rate through the valve�
Please refer to “06�B LED indications on page 9 for the
meaning of the remaining LED colours�
Valve open
= max air flow
LED
Valve shut
= lowest air flow
LED
7


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Duco DucoBox Focus at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Duco DucoBox Focus in the language / languages: English as an attachment in your email.

The manual is 5.88 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Duco DucoBox Focus

Duco DucoBox Focus Installation Guide - Dutch - 16 pages

Duco DucoBox Focus Installation Guide - French - 16 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info