810223
6
Zoom out
Zoom in
Previous page
1/16
Next page
6
ENGLISH
L2000631 Installation guide for DucoBox Focus (Revision N | 19.10.2023)
RF (wireless communication)
RF components have a maximum free-field range of 350 metres� This distance
will be much less in a building because of obstacles� Therefore, you will need
to take objects such as walls, concrete and metal into account� All slave
components (except those which are battery powered) also act as repeaters�
Signals from components that are unable to make a (strong) connection with
the master component are forwarded automatically via no more than one other
non-battery-powered component (= hop)� Please refer to information sheet
RFcommunication (L8000018) at www�duco�eu for further information�
DUCO RF
Power supply 230 VAC
Wiring 1,5 mm²
Frequency 868 Mhz
Maximum distance 350 m, free field (less
through obstacles)
Maximum number
of components
Up to 25 wireless
components in a
single system
Wired (cabled communication)
Wired components can be daisy-chained (= recommended)� This means that a
separate cable will not be required for each component� A single central power
supply can be used�
The cable required is a 5x0�75 mm² data cable� We strongly advise using a
shielded cable� This is to prevent any interference that may affect the data
communication� Any Tronic window ventilators will be supplied with a 5x0�25
mm² cable which can be connected via a splicing terminal block�
DUCO WIRED
Power supply 24 VDC
Wiring
5 x 0,75 mm²
(5 x 0�25mm² from Tronic
window ventilators)
Maximum distance up to 300 m
Maximum number
of components
Up to 99 wired
components in a
single system
04 Control valves
The control valves, whether or not they are fitted with a sensor for measuring CO or humidity, can be built into the DucoBox Focus�
Together with the fan, they ensure the correct exhaust airflow rate in the right room�
A control valve with combined CO2 and RH measurement can only be used with a DucoBox Focus with a software
version of 11.2 or higher.
A DucoBox Focus can contain up to a maximum of 7 control valves (= one per supply duct)� This can be expanded to a maximum of
11 control valves by using the ‘Control Valve Manifold’ (item 0000-4454)�
A control valve must always be provided for each ventilation duct connected!
04.A Mounting the control valves
Slide the control valve into the locations
provided in the DucoBox Focus� Connect
the ‘VALVE’ connector on the DucoBox
to IN on the control valve� If applicable,
connect OUT on the valve to IN on another
control valve to be added� At least one
valve must be connected to the DucoBox at
any time�
IN
OUT
IN
IN
OUT
OUT
TIP: Use the letter labels on the DucoBox
and the valves (A/B/C/D/E/F/G) to give
these the same letter, so that the valves
always remain in the same position�
IN
OUT
BBEE
AAFF
DD
GG
CC
A
B
C
D
E
F
G
6


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Duco DucoBox Focus at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Duco DucoBox Focus in the language / languages: English as an attachment in your email.

The manual is 5.88 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Duco DucoBox Focus

Duco DucoBox Focus Installation Guide - Dutch - 16 pages

Duco DucoBox Focus Installation Guide - French - 16 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info