810271
61
Zoom out
Zoom in
Previous page
1/64
Next page
Installation manual
61
Malfunctions
Error code
F12
F13/F14
F15
F15
(PowerVent®)
F16
F17
Problem
ESYS is not released
(no ionisation). Flame Loss when only
the main burner (F13) is on or
both burners (F14) are on
No ESYS
(see fig. 6-2)
High limit error
Fan doesn't start,
appliance doesn't spark
Fan starts,
appliance doesn’t spark
Hardware Error ESYS
3 subsequent, unsuccessful
ignition cycles
Possible cause
ESYS is in hard-lock
Ionisation pin short-circuited
Ionisation current too critical
(0.8 ≤ ionisation < 1.8 μA)
Suffocation due to poor flue
gas channel
Suffocation when using PowerVent®
24 hour check control
(only in case of F13)
Gas has fallen away
Gas control
defective
ESYS
detatched
ESYS incorrectly mounted
Pins on the connector on the gas
control are bent
High limit bridge defective
Fan defective
Diff. pressure hoses leak
Diff. pr. sensor defective
Ctrl signal cable defective
Concentric system defective
and/or leaking
ESYS defective (burner device)
Premature interruption ignition cycle,
also see F08
Remedy
Wait half hour until ESYS
resets itself
Remove chips, vermiculite or glow
material lying against the
ionisation pin
Increase ionisation current to
≥ 1.8 μA by rearranging vermiculite
and removing chips and dust
from the burner openings
Check the concentric system
Check the setting of the appliance
Check the pressure setting of
the PowerVent® system
Reset with remote control
(consult PowerVent® manual)
Check gas supply
Replace the gas control
Attach the ESYS
Mount the ESYS correctly
Bend them straight
Check High limit bridge ESYS
Replace fan
Check connections and hoses
Replace/repair
Replace diff. pr. sensor
Replace control cable
Check concentric system for
leaks and defects
Repair/replace
Replace ESYS (burner device)
After 30 min. F17 can be reset w.
mains voltage on appliance,
see F08
61


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for DRU Maestro 105 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of DRU Maestro 105 in the language / languages: English as an attachment in your email.

The manual is 6.2 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of DRU Maestro 105

DRU Maestro 105 User Manual - German - 28 pages

DRU Maestro 105 User Manual - Dutch - 64 pages

DRU Maestro 105 User Manual - French - 64 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info