528137
37
Zoom out
Zoom in
Previous page
1/60
Next page
English
35
INSTALLATION MANUAL
Global 70 / 70 XT
7.1.1 Placing / replacing the batteries
Follow the procedure below when placing the batteries:
Open the door of the control box.
• Pick up the receiver.
• Slide the cover off.
• Place or remove the 4 penlite (AA type) batteries.
!Caution - Avoid a short circuit between the
batteries and metal objects/parts;
- Observe the “+” and “-” poles of the
batteries and the holder;
- Use alkaline batteries.
Slide back the cover.
Place back the receiver.
!Caution Batteries are regarded as “small chemical
waste” and may therefore not be dis-
posed with the household rubbish.
8. Final check
In order to check whether the appliance is working pro-
perly and safely, you must perform the following checks
before the appliance is used.
8.1 All connections must be gastight.
All connections must be gastight.
!Caution The gas control can be subjected to a
maximum pressure of 50 mbar.
Check the connections for gastightness
8.2 Gas pressure / pre-pressure
The burner pressure is set at the factory; see data plate. It
is not necessary to check the burner pressure.
The pre-pressure in house installations
should be checked, as they can vary.
Check the pre-pressure; see fi g. 17 for the measuring nipple
on the gas control.
Contact the gas company if the pre-pressure is not correct.
8.3 Ignition pilot and main burner
For igniting the pilot and main burners, see the
User Manual, chapter 4, section 4.2, Remote Control.
- During the ignition process, you are not
allowed to operate control button B on
the gas control manually;
- Always wait 5 minutes after the pilot
burner has gone out, before you re-ignite
the appliance.
- Do not turn the pilot burner lower by
using the settings on the gas control.
8.3.1 Pilot burner
Check the ignition of the pilot burner:
- the pilot burner should start at the fi rst attempt.
If the pilot burner does not ignite:
check if the ignition sparks:
a) If not, the ignition cable is probably not lying free from
metal parts;
b) If it does, there is probably still air in the pipe.
Bleed the pipe and/or
Lay the ignition cable free from metal parts.
8.3.2 Main burner
The burner should ignite smoothly and
should not pop as a result of delayed
ignition.
Check the function of the main burner from the standby
(pilot burner) position:
- after opening the gas valve, the main burner should burn
within a few seconds.
!Tip When the gas valve is opened, the motor
will run; this is audible.
1) If the main burner does not burn:
Check if button A on the gas control is in the position ON;
Check if the space surrounding the pilot burner is free
from objects;
Check the placement of the wood set.
If necessary, correct the above mentioned faults.
Test the main burner 5x for a good operation.
2) If the main burner ignites, but goes out again after
approx. 22 seconds, please:
Check the wiring of thermocouple 2 for:
- Loose wiring;
- Wrongly connected wiring;
- Short-circuit;
- Broken wire.
Check if thermocouple 2 is dirty.
Check if thermocouple 2 is positioned correctly in the
ame; see fi g. 18.
Check if thermocouple 2 is defective; see chapter 11,
table 4 under J7.
Check if the receiver is defective; see chapter 11, table 4
under J8.
If necessary, correct the above mentioned faults.
Test the main burner 5x for a good operation.
8.4 Flame image
The fl ame image can only really be assessed when the ap-
pliance has been burning for several hours. Volatile compo-
nents from paint, materials, etc., which evaporate in the fi rst
hours, will affect the fl ame image.
Caution
Caution
Caution
Caution
37


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for DRU GLOBAL 70 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of DRU GLOBAL 70 in the language / languages: English, Dutch as an attachment in your email.

The manual is 7,1 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of DRU GLOBAL 70

DRU GLOBAL 70 User Manual - German - 20 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info