528137
34
Zoom out
Zoom in
Previous page
1/60
Next page
32
INSTALLATION MANUAL
!Caution Some heat-resistant insulation materials
contain volatile components that will
spread an unpleasant smell for a prolon-
ged time; these are not suitable.
Place the concentric system as follows:
Build the system up from (the connection stump of)
the appliance.
Connect the concentric pipe pieces and, if necessary,
the bends.
On each connection, apply a clip binding with silicon
sealing ring.
Use a self-tapping screw to fi x the clip binding to the pipe
on locations that cannot be reached after installation.
Apply suffi cient clamps, so that the weight of the pipes
does not rest on the appliance.
Determine the remaining length of the roof terminal.
Make sure the roof terminal has the right dimensions.
!Caution Make sure that the right insertion length
is maintained.
Connect the roof terminal to the concentric pipes.
!Caution - Make sure that the universal tile fi ts well
with the surrounding tiles;
- Make sure that the adhesive plate fi ts well
onto the fl at roof.
6.5.4 Connection of existing chimney
It is possible to connect the appliance to an existing
channel.
A fl exible SS pipe is placed in the chimney for discharging
ue gases. The surrounding space is used to supply
combustion air.
The following requirements apply when connecting to an
existing chimney:
- only allowed when used in combination with the special
DRU chimney kit. The installation manual is also supplied;
- the dimensions should be at least 150 x 150 mm;
- the vertical length has a maximum of 12 meters;
- the horizontal length has a maximum of 3 meters;
- the existing chimney has to be clean;
- the existing chimney has to be tight.
If the appliance is installed into an existing chimney by
means of a chimney kit, there may be a slight loss in heat
output.
For setting the appliance, the same conditions/instructions
apply as for the concentric system described above.
6.6 Placing the chimney breast
The appliance is designed to be mounted tightly in a new
chimney breast.
In order to provide proper heat discharge, there should be
suffi cient space around the appliance.
The chimney breast should be ventilated suffi ciently by
means of ventilation holes.
- Use non combustible and heat-resistant
materials for the chimney breast, inclu-
ding the top of the chimney breast, the
material in the chimney breast and the
back wall of the chimney breast;
- Make sure that the appliance is not car-
rying the weight of the chimney breast
when using stone-like materials;
- The ventilation holes – which should be
mounted as high as possible – should have
a combined passage of at least 200 cm
2
.
!Caution When placing the chimney breast, you
should take the following into account
(see fi g. 2a and fi g. 2b):
- the location of the control box (K): it
should be placed with a distance of
850 mm to the left or to the right of the
appliance – as low as possible;
- the measurements of the control box; see
Placing the Control Box section 6.7;
- the location of the ventilation holes (V);
- measurement of the pane, so it can be
placed/removed after placing the chimney
breast;
- the protection of the gas control and the
pipes against cement and plaster.
!Tip You should preferably apply the ventila-
tion holes on both sides of the chimney
breast. You can use DRU ventilation
elements.
Check whether the concentric system is placed correctly.
Check the fi xture of the clip binding with self-tapping
screws on places that cannot be reached later on.
Maintain suffi cient space around the appliance in the chim-
ney breast, so the heat can escape:
- minimum internal height: 1350 mm;
- minimum internal width: 1450 mm.
Do not apply plaster on or over the fl anges (see fi g. 2a
and fi g. 2b, maximum plaster line M), because:
- the heat of the appliance could cause cracks;
- it will no longer be possible to remove/place the pane.
When using stone-like materials and/or plaster fi nishing,
the chimney breast should dry for at least 6 weeks before
it is taken into operation, in order to prevent cracks.
6.7 Placing the control box
The control box (K) is placed as low as possible in the
chimney breast (see fi g. 2a and fi g. 2b). The control box is
not part of the appliance's standard equipment and is availa-
ble at your dealer.
!Caution The bottom of the control box may not
be placed higher in the appliance, than the
burner bed.
Caution
34


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for DRU GLOBAL 70 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of DRU GLOBAL 70 in the language / languages: English, Dutch as an attachment in your email.

The manual is 7,1 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of DRU GLOBAL 70

DRU GLOBAL 70 User Manual - German - 20 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info