571711
31
Zoom out
Zoom in
Previous page
1/64
Next page
English
29
Global 100 BF
INSTALLATION MANUAL
3.3 Precautions / safety instructions during
installation
Carefully observe the following precautions/safety
regulations:
you should only install and maintain the appliance if you
are a competent installer in the fi eld of atmospheric gas-
red heating;
do not make any changes to the appliance;
use non combustible and heat-resistant materials for the
chimney breast, including the top of the chimney breast,
the material in the chimney breast and the back wall
against which the appliance will be placed;
take suffi cient measures to prevent temperatures of a wall
behind the chimney breast becoming too high, including
the materials and/or objects behind the wall;
comply with the minimum required internal measure-
ments of the chimney breast;
ventilate the chimney breast by means of the ventilation
holes, which will form a combined passage of at least
200 cm
2
;
only use the fl ue gas discharge / combustion air supply
system supplied by DRU;
do not place the appliance too tightly against the back
wall;
make sure the space between the adjustable feet is kept
free;
do not cover the appliance and/or do not wrap it in an
insulation blanket or any other material;
make sure that combustible objects and/or materials have
a distance from the appliance of at least 500 mm
only ever use the supplied wood / pebble set;
place the wood / pebble set exactly as described;
make sure the pilot burner and the space around it is kept
free;
make sure thermocouple 2 and the space around it are
kept free;
make sure there is no dirt in gas pipes and connections;
mount a gas tap directly next to the appliance;
check the connections for gastightness before using the
appliance;
use heat resistant electrical wiring;
place the electrical wiring in such a way that they are free
from the appliance;
replace torn or broken panes;
do not ignite the appliance until it is fully installed.
4. Instructions
Observe the following items during installation in order to
guarantee a proper and safe operation of the appliance:
mount the control box supplied as low as possible;
avoid that the ignition cable runs over the receiver;
avoid that the ignition cable touches or crosses the
antenna;
make sure the ignition cable cannot come into contact
with other wires;
avoid that the ignition cable runs alongside metal parts, in
order to prevent weakening of the spark;
properly fi nish the edges in case of a tight construction;
do not apply plaster on or over the fl anges;
avoid damages when removing/placing the pane;
clean the pane before you use the appliance, in order to
prevent dirt from burning in the glass;
make sure that the wires of thermocouple 2 cannot come
into contact with hot parts.
5. Removing the packaging
Note the following items when removing the packaging:
Check the appliance for damages during transport.
If necessary, contact DRU Service.
After removing the packaging, you should have the following
components:
- Socket spanner; you will fi nd it in the space between the
assembly frame and the combustion chamber;
- Decorative strips; you will fi nd them in the abovementi-
oned space as well;
After removing the pane, you can take the wood / pebble
set and the box with parts out of the combustion chamber.
!Caution Avoid damages when removing/placing the
pane.
Remove the pane as described in section 6.10.1.
Remove the wood / pebble set from the combustion
chamber.
Remove the box containing parts from the combustion
chamber.
In appendix 1/ table 5 you can see which parts you should
have after removing the packaging.
Contact DRU Service if you do not have all the parts after
you fi nished removing the packaging.
Dispose packaging in accordance with local regulations.
6. Installation
!Caution Install the appliance in the order described
in this chapter.
6.1 Regulations
Observe the applicable (installation) regulations.
Observe the regulations/instructions in this manual.
6.2 Type of gas
The data plate indicates for which type of gas, gas pressure
and for which country this appliance is intended. The data
plate is connected to a chain. It should remain connected to
the chain.
Check whether the appliance is suitable for
the type of gas and the gas pressure used at
the location.
Caution
31


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for DRU GLOBAL 100 BF at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of DRU GLOBAL 100 BF in the language / languages: Dutch as an attachment in your email.

The manual is 2,87 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of DRU GLOBAL 100 BF

DRU GLOBAL 100 BF User Manual - English - 20 pages

DRU GLOBAL 100 BF User Manual - German - 20 pages

DRU GLOBAL 100 BF User Manual - French - 20 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info