INSTALLATION MANUAL
Preface
DRU, a manufacturer of gas-fi red heating appliances
develops and produces products that comply with the
highest quality, performance and safety requirements.
This guarantees that the user will be able to enjoy using his
product for many years to come.
This appliance has a CE marking, which means that it
complies with the essential requirements of the European
gas appliance directive.
Two manuals are supplied with the appliance: the installa-
tion manual and the user manual. These have been included
in one booklet.
As an installer, you must be competent in the fi eld of
atmospheric gas-fi red heating.
The installation manual will give you the information you
need to install the appliance in such a way that it will
operate properly and safely.
This manual discusses the installation of the appliance and
the regulations that apply to the installation. In addition, you
will fi nd technical data for the appliance and information on
maintenance, any malfunctions that might occur and their
possible causes.
The fi gures are included at the back of this booklet
(Appendix 3).
Please carefully read and use this installation manual.
The following symbols are used in the manual to indicate
important information:
Work to be performed.
! Tip Suggestions and recommendations.
! Caution You will need these instructions to prevent
problems that might occur during installa-
tion and/or use.
You need these instructions to prevent fi re,
personal injury or other serious damages.
After delivery you should give this booklet containing
the manuals to the user.
1. Introduction
A convection set - the Max vent system - is available opti-
onally. When using the Max vent system, the construction
measurements will differ.
This version of the Global 100 BF is suitable for natural gas
or propane. The safe operation of the appliance is guaran-
teed by the use of a second thermocouple fi tted to the
main burner.
The Global 100 BF is a room-sealed atmospheric gas-fi red
heating appliance. A room-sealed appliance does not extract
the combustion air from the living environment, but from
outside. This is done by means of a combined fl ue gas
discharge system / combustion air supply system. In this
concentric system, the outer pipe functions as the air sup-
ply and the inner pipe functions as the fl ue gas discharge.
This system can be installed through the wall or through
the roof.
These appliances are built within a chimney breast.
In order to reach a proper heat discharge, the chimney
breast must be ventilated. DRU is able to supply various
ventilation elements.
The appliances are supplied with a wireless remote control
that works on batteries.
2. CE declaration
We hereby declare that the design and construction of
DRU’s atmospheric gas-fi red heating appliance comply with
the essential requirements of the Gas Appliance Directive.
Product: atmospheric gas-fi red heating appliance
Type: Global 100 BF
Applicable EEC directives:
2009/142/EC
Applied harmonized standards:
NEN-EN-613
NEN-EN-613/A1
Internal measures by the company guarantee that applian-
ces produced in series comply with the essential require-
ments of the prevailing EEC directives and the standards
derived from them.
This declaration will lose its validity if adjustments are made
to the appliance, without prior written permission by DRU.
M.J.M. Gelten
General manager
DRU verwarming B.V.
Postbus 1021, 6920 BA Duiven
Ratio 8, 6921 RW Duiven
www.dru.nl
3. Safety
3.1 General
- Carefully read this chapter on safety,
before you start performing instal-
lation or maintenance work;
- Please observe the general regu-
lations and the precautions/safety
instructions in this manual.
3.2 Regulations
Please install the appliance in accordance with the applica-
ble national, local and constructional (installation) regulati-
ons.
Caution
Caution
30


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for DRU GLOBAL 100 BF at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of DRU GLOBAL 100 BF in the language / languages: Dutch as an attachment in your email.

The manual is 2,87 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of DRU GLOBAL 100 BF

DRU GLOBAL 100 BF User Manual - English - 20 pages

DRU GLOBAL 100 BF User Manual - German - 20 pages

DRU GLOBAL 100 BF User Manual - French - 20 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info