INSTALLATION MANUAL
!Caution
When installing a built-in appliance, always take the following into account:
The minimum construction measurements according to Appendix 3, Fig. 1 and 2.
The construction height of the appliance.
Ø
Provide a gas connection at the location. For details, see section 5.2.
Ø
Make a passage for the concentric system; for details, see section 5.8.3.
!Caution
Additional instructions for the appliance to be installed can be found from section 5.10.
5.5 Placing a built-in appliance (if applicable)
Not all built in DRU appliances are supplied with a control hatch.
!Caution
Built in appliances must be installed with the DRU control hatch. This is necessary to ensure a durable, safe and
proper operation. The DRU control hatch can be ordered separately. Exceptions are:
Appliances with supplied DRU guard cabinet. The DRU guard cabinet is intended for installation with a suspended
platform. If the appliance will be connected to the DRU PowerVent system, the DRU control hatch has to be used
after all.
The gas control is mounted to the appliance. It must be taken out and placed in the control hatch at a later time.
For placing the gas control in the control hatch, see section 5.7.
Proceed as follows:
Ø
Loosen the bracket with the gas control by loosening the self-tapping screws and screw the self-tapping screws
back in the appliance.
Ø
Place the bracket with gas control, together with the wiring of the ignition/ionisation cable(s), the flexible gas
hose(s) and type plate with chain in the direction of the control hatch.
!Caution
The data plate should remain connected to the chain.
Ø
Set the height of the appliance using the adjustable feet.
Ø
Make the appliance level at the same time.
!Tip
The construction frame can be adjusted afterwards for most 2- or 3 sided appliances. This allows a good contact of
the construction frame with the chimney breast. Adjustment should take place before the appliance is built in.
After building in, adjustment is no longer possible. For 2- or 3-sided appliances that cannot be adjusted, we refer
to section 5.10 'Additional instructions'.
!Caution
Do not ignite the appliance before the gas, discharge and electric connections have been fully installed, first
observe the procedure described in chapter 7.3.
5.6 Placing the chimney breast (if applicable)
For a good heat discharge and operation of the appliance, there should be sufficient space around the appliance.
The chimney breast should be ventilated sufficiently by means of ventilation holes (incoming and outgoing).
!Caution
When an appliance is built in the floor, please take into account the minimum distances from a combustible
floor. If applicable, additional information about this is provided from section 5.10 'Additional instructions'.
7
7


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for DRU Cosmo Tunnel at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of DRU Cosmo Tunnel in the language / languages: English as an attachment in your email.

The manual is 8.69 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of DRU Cosmo Tunnel

DRU Cosmo Tunnel User Manual - English - 28 pages

DRU Cosmo Tunnel User Manual - German - 28 pages

DRU Cosmo Tunnel Installation Guide - German - 40 pages

DRU Cosmo Tunnel User Manual - Dutch - 28 pages

DRU Cosmo Tunnel Installation Guide - Dutch - 40 pages

DRU Cosmo Tunnel Installation Guide - French - 40 pages

DRU Cosmo Tunnel User Manual - French - 28 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info