3.4 Principle of ignition cycle
Below you will find a brief description of how this appliance is ignited. The receiver in the appliance will get a
signal from the remote control to start the ignition process. The receiver will get the signal to start the ignition
process. This signal is passed on to the burner device, after which, if applicable, the relay for the Powervent
System® is switched. After an 8 second interval, the ignition on the spark electrodes will start. If no Powervent
System® is connected, only the relay will switch and the ignition will start immediately. The main burner will be
ignited at about 50% of its capacity. This will prevent a larger amount of gas in the combustion chamber, if no
ignition takes place. When the gas ignites, ionization will have to be detected. In order to make sure the flame has
passed over, this will take place at the other side of the burner. When ionization is detected, the gas control will
modulate to 100%.
In case of an appliance with a switchable second burner, the second valve is switched (you will be able to hear a
'click') in order to ignite the second burner. After ignition of the second burner, the appliance will always go to the
full position (full capacity). This will guarantee that the second burner will actually ignite. The second burner can
be switched on and off manually, by means of the remote control. In case of switching on manually, the appliance
will first return to full load.
!Caution
The appliance's control unit is characterized by stringent safety requirements. It is possible that the burning
appliance switches off automatically and then switches back on again. This is not a failure, but a check.
The moment the appliance's control unit is connected to mains voltage, the control unit will perform this check
every 24 hours. If the appliance is burning at that time, the appliance will extinguish and then start again
immediately.
If you wish to prevent this, you can remove the plug and insert it again at a time during the 24 hours when the
appliance is never or hardly ever burning.
4. Removing the packaging
Note the following items when removing the packaging:
Ø
Remove all packaging materials.
Ø
Remove all supplied components in, on and/or at the appliance.
Ø
Check the appliance and accessories for damages (during transport).
Ø
If necessary, contact your supplier.
Ø
Never install if an appliance is damaged!
Ø
Remove any screws that are used to fix the appliance to a platform or pallet.
!Caution
The glass pane(s) is/are made of a ceramic material. Very small irregularities in the glass panes cannot be avoided,
but are within the required quality standards.
!Caution
Keep plastic bags away from children.
Appendix 2, table 1 indicates which components should be available after unpackaging.
Ø
Contact the supplier if you find that not all components have been supplied.
Ø
Packaging must be disposed of in accordance with the regulations.
5
5


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for DRU Cosmo Tunnel at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of DRU Cosmo Tunnel in the language / languages: English as an attachment in your email.

The manual is 8.69 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of DRU Cosmo Tunnel

DRU Cosmo Tunnel User Manual - English - 28 pages

DRU Cosmo Tunnel User Manual - German - 28 pages

DRU Cosmo Tunnel Installation Guide - German - 40 pages

DRU Cosmo Tunnel User Manual - Dutch - 28 pages

DRU Cosmo Tunnel Installation Guide - Dutch - 40 pages

DRU Cosmo Tunnel Installation Guide - French - 40 pages

DRU Cosmo Tunnel User Manual - French - 28 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info