Parameter description:
Traffic Rate Unit Set the unit of traffic rate for Ingress/Egress.
Ingress Rate
Set up the limit of Ingress bandwidth for the port you
choose. Incoming traffic will be discarded if the rate
exceeds the value you set up in Data Rate field. Pause
frames are also generated if flow control is enabled. The
format of the packet limits to unicast, broadcast and
multicast. Valid value of Port 1~24 ranges from
128~3968 kbps.
Choose the Ingress Rate number from the drop down list.
The corresponding rate will be shown on the right side.
Default: No Limit
Egress Rate
Set up the limit of Egress bandwidth for the port you
choose. Outgoing traffic will be discarded if the rate
exceeds the value you set up in Data Rate field. Pause
frames are also generated if flow control is enabled.
The format of the packet limits to unicast, broadcast and
multicast. Valid value of Port 1~24 ranges from
128~3968 kbps.
Choose the Egress Rate number from the drop down list.
The corresponding rate will be shown on the right side.
Default: No Limit
3
3
.
.
6
6
.
.
3
3
S
S
t
t
o
o
r
r
m
m
C
C
o
o
n
n
t
t
r
r
o
o
l
l
Function name:
Storm Control Configuration
Function description:
Storm Control is used to block unnecessary multicast and broadcast frames that reduce
switch’s performance. When the function is enabled and Storm Control rate settings are
detected as exceeded, the unnecessary frames would be dropped
62


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Draytek VigorSwitch G1240 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Draytek VigorSwitch G1240 in the language / languages: English as an attachment in your email.

The manual is 1,7 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info