The top of the convection space must be closed
airtight by means of a closing plate of
incombustible and heat-resistant material.
The cover plate must be level and placed at least
30 cm below the flue opening in the ceiling.
Air inlet grates must be fitted at the bottom of the
hearth to allow ambient air to flow in. The minimum
air inlet vent is 250 cm
2
. If the space is not
sufficiently ventilated, you must provide for outside
air to be allowed in by means of the outside air
connection kit or an optional adjustable damper.
Air outlet grates must be fitted at the top of the
hearth and just below the cover plate. The
minimum air outlet opening is 500 cm
2
.
The inlet and outlet grates are available as
options.
Do not use combustible material in the
convection space, and avoid the effect of
thermal bridging when using materials that
conduct heat.
Follow the instructions below when building the
hearth:
1. Build the base of the hearth and fit the air inlet
grates into the masonry.
You can place the air inlet grates on all sides of
the base.
Make sure the door of the appliance can swing
freely over the hearth floor.
2. Build up the hearth up to the smoke dome.
Ensure that a clearance of 2 mm is maintained
between the stove and the masonry to
accommodate the thermal expansion of the
stove.
3. The inside of the convection space may, if
desired, be cladded with reflective, insulating
material.
Additional cladding of the convection space
prevents unnecessary thermal radiation
towards outer walls and/or adjacent rooms. It
also prevents damage to the insulation in the
walls of the hearth.
4. Build the rest of the hearth up to the flue gas hole
in the ceiling.
The masonry may not rest on the stove. Use a
support such as a steel beam. Leave a
clearance of at least 3 mm between the
support and the appliance.
5. Close the convection space with the cover plate.
6. Put the air outlet grates under the cover plate.
7. Make an opening above the cover plate in order to
prevent any pressure build-up.
The figure below shows an example of the placing of a
stove in a hearth built in accordance with the
instructions given above.
L M
09.20015.043
A
B
C
D
E
F
G
H
I
J
K
N
O
A Chimney (flue)
B Gasket
C Cover plate
D Insulation 10 cm
E Fireproof wall min. 10 cm (e.g. cellular concrete)
F Combustible wall
G Convection space
10
Subject to change because of technicalimprovements
36


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Dovre 2576CBS at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Dovre 2576CBS in the language / languages: English, German, Dutch, French, Italian, Spanish as an attachment in your email.

The manual is 28,41 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info