784483
10
Zoom out
Zoom in
Previous page
1/64
Next page
10
NOTICE The power supply unit is plugged into a wall socket, usually
where the two wires from your assembly location come out of
the wall in the interior of the house.
The provided mains adapter is not outdoor-ready and for
indoor-use only.
OPTION 
Power supply and network connection using PoE (Power over
Ethernet)
To power the device via a PoE-Switch (e.g. D-Link DGS-1008P) or PoE-
Injector (e.g. DoorBird Gigabit PoE Injector A1093), use a CAT.5 cable or
higher in accordance with the PoE standard IEEE 802.3af Mode A.
A CAT.5 cable or higher must be used for this purpose, as network signals
can only be transmitted over completely insulated, shielded and twisted
cables. If you use PoE as a source of power, the four wires for PoE then
simultaneously form the data line. The device will not start if your PoE-
Switch/PoE-Injector does not support the PoE Standard IEEE 802.3af
Mode A.
NOTICE Do not combine the power supply from the power supply unit
(mains adapter) with the power supply via PoE.
You can find further information about PoE here:
http://www.doorbird.com/poe
1. Disconnect the PoE-Switch or PoE-Injector from the power grid.
2. Place the network cable in the installation site of the device.
If you must power more than one device
with one power supply , we recommend
to use a PoE-Switch with PoE Standard
IEEE 802.3af Mode A or an appropriate
DIN rail power supply (see “OPTION 3”).
Theoretically (not recommended by us!),
an unshielded, but over the whole length
(max. 80 m/262 ft) twisted bell wire with
two pairs of wires (first twisted pair of
wires: “T+, T-”, second twisted pair of wi-
res “R+, R-”) can be used for the network
and PoE transmission as an alternative
to a Cat.5 network cable or better. This is
comparable to a Cat.3 network cable. In
this case, however, we cannot guarantee
the data throughput or the stability of
the network connection and power sup-
ply; this must be measured and checked
on site by qualified personnel over several
hours (network data is transmitted at
high frequency, therefore a shielded
Cat.5 network cable twisted in pairs or
better must normally be used).
For easier installation we strongly
recommend to remove the plug from
screw connection terminal while you
connect the cables and wires.
CONNECTING THE DEVICE
It is possible to connect the cables and wires to the device conveniently
and safely via the labeled screw connection terminal. You can connect all
necessary cables and wires to the device now.
NOTICE Please remove any cables and wires from the connection ports
of the device that you do not need.
The product comes with a disassembly tool that
allows you to safely remove the connector from the
screw terminal socket. Please do not use any other
tool, e.g. a screwdriver, as this may damage the
circuit board of the device.
OPTION 
Power supply using a DIN rail power supply unit
Alternatively to the mains adapter, we offer DIN rail power supplies in
our online shop, which can be installed by a specialist. The network
connection is then made via a network cable or alternatively via WiFi.
10


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Doorbird A1121 Series IP Access Control Device at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Doorbird A1121 Series IP Access Control Device in the language / languages: English, German, French, Spanish as an attachment in your email.

The manual is 11 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Doorbird A1121 Series IP Access Control Device

Doorbird A1121 Series IP Access Control Device Additional guide - English, German, French, Spanish - 1 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info