E1, E1
E1
E1
Digital input, max. 0 VDC / VAC, 0 A, e.g. for storey-call button
Please make sure to add no voltage on these ports. Extra voltage may destroy the
device immediately.
E2, E2
E2
E2
Digital input, max. 0 VDC / VAC, 0 A, e.g. for a second storey-call button
Please make sure to add no voltage on these ports. Extra voltage may destroy the
device immediately.
R1, R1 Bi-stable latching relay #1, max. 24 VDC / VAC, 1 A. Security feature: The relay keeps its state
even in the case of loss of power. You can configure the default state of the relay (open/
close) via the DoorBird App. These ports can be used to connect e.g. an electric door opener
or to call an elevator. The device does not supply power to the connected device. The power
supply for the electric door opener must be installed separately.
R2, R2 Bi-stable latching relay #2, max. 24 VDC / VAC, 1 A. Security feature: The relay keeps its state
even in the case of loss of power. You can configure the default state of the relay (open/
close) via the DoorBird App. These ports can be used to connect e.g. an electric door opener
or to call an elevator. The device does not supply power to the connected device. The power
supply for the electric door opener must be installed separately.
R3, R3 Bi-stable latching relay #3, max. 24 VDC / VAC, 1 A. Security feature: The relay keeps its state
even in the case of loss of power. You can configure the default state of the relay (open/
close) via the DoorBird App. These ports can be used to connect e.g. an electric door opener
or to call an elevator. The device does not supply power to the connected device. The power
supply for the electric door opener must be installed separately.
15 VDC - 15 to 48 V DC Power supply input, negative pole (-). Please connect the black wire of
the power supply unit (mains adaptor) supplied with this device if you do not power the
device using PoE.
Do not power the device simultaneously via the power supply from the power
supply unit (mains adaptor) and the power supply via PoE.
15 VDC + 15 to 48 V DC Power supply input, positive pole (+). Please connect the red wire of the
power supply unit (mains adaptor) supplied with the device here, if you do not power the
device using PoE.
Do not power the device simultaneously via the power supply from the power
supply unit (mains adaptor) and the power supply via PoE.
R
R
R
R
NOTICE
NOTICE
NOTICE
NOTICE
Please take care when connecting the cables and wires. Connecting the cables and wires the wrong
way may damage the device. Wires without insulation material must not protrude out of the screw
connection terminal plugs, it may lead to electrical short and damage the device.
NOTICE
R
R
12


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Doorbird A1101 Series IP Video Indoor Station at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Doorbird A1101 Series IP Video Indoor Station in the language / languages: English, German, French, Spanish as an attachment in your email.

The manual is 7.43 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Doorbird A1101 Series IP Video Indoor Station

Doorbird A1101 Series IP Video Indoor Station Additional guide - English - 1 pages

Doorbird A1101 Series IP Video Indoor Station User Manual - English - 3 pages

Doorbird A1101 Series IP Video Indoor Station Additional guide - German, French, Spanish - 1 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info