798246
20
Zoom out
Zoom in
Previous page
1/68
Next page
EN-2 452237.66.51 · FD 9912 www.gdts.one
English WI 65TU - WI 95TU
1 Please read immediately
1.1 Important notes
ATTENTION!
!!
Work on the heat pump must only be performed by
authorised and qualified after-sales service technicians!
ATTENTION!
!
!
When operating or maintaining a heat pump, the legal
requirements of the country where the heat pump is operated
apply. Depending on the refrigerant fill quantity, the heat
pump must be inspected for leaks at regular intervals by a
certified technician, and these inspections must be recorded.
ATTENTION!
!
!
The well water must comply with the required water quality
standards. (see Cap. 9.4 on pag. 10)
ATTENTION!
!
!
If the heat pump or circulating pumps are controlled
externally, a flow rate switch is required to prevent the
compressor from being switched on when there is no volume
flow.
ATTENTION!
!!
The heat pump must not be tilted more than 45° (in any
direction).
ATTENTION!
!
!
Before commissioning, the transport fastening must be
removed.
ATTENTION!
!
!
Flush the heating system prior to connecting the heat pump.
ATTENTION!
!
!
The maximum test pressure in the heating circuit and the
primary circuit is 6.0 bar. This value must not be exceeded.
ATTENTION!
!!
It is essential that the dirt trap included in the accessories
pack is installed in the return (inlet).
ATTENTION!
!
!
The flow rate switch available as an accessory must be
installed in the flow (outlet) of the heat source.
ATTENTION!
!
!
Ensure that there is a clockwise rotating field: With incorrect
wiring the starting of the heat pump is prevented. A
corresponding warning is indicated on the display of the heat
pump manager (adjust wiring).
ATTENTION!
!
!
It is not permitted to connect more than one electronically
regulated circulating pump via a relay output.
ATTENTION!
!!
Start-up must be performed in accordance with the
installation and operating instructions of the heat pump
manager.
ATTENTION!
!
!
The supplied dirt trap must be inserted in the heat source inlet
of the heat pump to protect the evaporator against the ingress
of impurities.
ATTENTION!
!
!
Disconnect all electrical circuits from the power source prior
to opening the device.
1.2 Intended use
This device is only intended for use as specified by the manu-
facturer. Any other use beyond that intended by the manufac-
turer is prohibited. This requires the user to abide by the rele-
vant project planning documents. Please refrain from
tampering with or altering the device.
1.3 Legal regulations and directives
This heat pump is designed for use in a domestic environment
according to Article 1, Paragraph 2 k) of Eu directive 2006/42/
EC (machinery directive) and is thus subject to the require-
ments of EU directive 2014/35/EC (low-voltage directive). It is
thus also intended for use by non-professionals for heating
shops, offices and other similar working environments, agricul-
tural establishments and hotels, guesthouses and other resi-
dential buildings.
This heat pump conforms to all relevant DIN/VDE regulations
and EU directives. Refer to the EC Declaration of Conformity in
the appendix for details.
The heat pump must be connected to the power supply in
compliance with all relevant VDE, EN and IEC standards. Any
further connection requirements stipulated by local utility com-
panies must also be observed.
The heat pump is to be connected to the heat source system
and the heating system in accordance with all applicable regu-
lations.
This unit can be used by children aged 8 and over and by per-
sons with limited physical, sensory or mental aptitude or lack of
experience and/or knowledge, providing they are supervised or
have been instructed in the safe use of the unit and understand
the associated potential dangers.
Children must not play with the device. Cleaning and user
maintenance must not be carried out by children without su-
pervision
ATTENTION!
!
!
Work on the heat pump must only be performed by
authorised and qualified after-sales service technicians!
ATTENTION!
!
!
When operating or maintaining a heat pump, the legal
requirements of the country where the heat pump is operated
apply. Depending on the refrigerant fill quantity, the heat
pump must be inspected for leaks at regular intervals by a
certified technician, and these inspections must be recorded.
More information can be found in the accompanying log book.
20


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Dimplex WI 65TU at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Dimplex WI 65TU in the language / languages: English, German, French as an attachment in your email.

The manual is 2.5 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info