English LA 33TPR
1Safety notes
1.1 Symbols and markings
Particularly important information in these instructions is
marked with CAUTION! and NOTE.
CAUTION!
!
!
Immediate danger to life or danger of severe personal injury or
significant damage to property.
NOTE
º
ºººº
Risk of damage to property or minor personal injury or
important information with no further risk of personal injury
or damage to property.
1.2 Intended use
This device is only intended for use as specified by the manu-
facturer. The air-to-water heat pump is to be used exclusively
for the heating and cooling of heating water. It can be used in
new or existing heating systems.
The heat pump is designed exclusively for outdoor installation.
The instructions in the chapter "Installation" must be observed.
Any other use beyond that intended by the manufacturer is
prohibited. This requires the user to abide by the relevant pro-
ject planning documents. Please refrain from tampering with or
altering the device.
1.3 Life cycle
The device is designed for a service life of 15 years. Mainte-
nance must be carried out as per the maintenance instructions.
Before the end of the intended service life and taking into ac-
count the current technical rules, the operator must carry out
an assessment regarding continued operation. Based on the
assessment, the operator must make a decision regarding con-
tinued operation, decommissioning or measures to be carried
out. If the assessment and any measures to be carried out are
not implemented before the end of the intended service life,
the device must be decommissioned.
1.4 Legal regulations and directives
The construction and design of the heat pump complies with all
relevant EU directives, EN/DIN/VDE regulations (see CE decla-
ration of conformity).
When connecting the heat pump to the power supply, the rele-
vant VDE, EN and IEC standards are to be adhered to. Any fur-
ther connection requirements stipulated by local utility compa-
nies must also be observed.
When connecting the heating system, all applicable regulations
must also be adhered to.
The device is filled with flammable refrigerant R290 (propane)
and is only intended for outdoor installation. Suitable safety
measures must be implemented for installation, assembly, op-
eration and disposal.
Activities on the heat pump must only be carried out by people
with the following knowledge. Use by people who have not
been instructed is not permissible.
Fig. 1.1:Phases and authorised people
CAUTION!
!
!
Work on the heat pump must only be performed by
authorised and qualified after-sales service technicians!
CAUTION!
!
!
When operating or maintaining a heat pump, the legal
requirements of the country where the heat pump is operated
apply. Depending on the refrigerant fill quantity, the heat
pump must be inspected for leaks at regular intervals by a
certified technician, and these inspections must be recorded.
1.5 Energy-efficient use of the heat
pump
By operating this heat pump, you are helping to protect the en-
vironment. A prerequisite for energy-efficient operation is the
correct design of the heat source system and heating system.
To maintain heat pump efficiency, it is particularly important to
keep the temperature difference between the heating water
and heat source to a minimum. For this reason, it is advisable to
design the heat source and heating system very carefully. A
temperature difference that is higher by 1 Kelvin (1°C) in-
creases the power consumption by around 2.5%. When de-
signing the heating system, it should be borne in mind that spe-
cial consumers such as domestic hot water preparation should
also be taken into consideration and dimensioned for low tem-
peratures. Underfloor heating systems (panel heating) are
optimally suited for heat pump use on account of the low flow
temperatures (30°C to 40°C).
It is important to ensure that the heat exchangers are not con-
taminated during operation, as this increases the temperature
difference, which in turn reduces the coefficient of perfor-
mance (COP).
When set correctly, the heat pump manager is also an essential
factor in the energy-efficient use of the heat pump. Further in-
formation can be found in the heat pump manager operating
instructions.
Activity Instructed peo-
ple
Qualified spe-
cialist
Authorised and
qualified after-
sales service tech-
nician
Transport, storage 
Installation
Installation 
Commissioning,
decommissioning
Operation 
Maintenance,
repair
Disposal
26


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Dimplex LA 33TPR at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Dimplex LA 33TPR in the language / languages: English, German, French as an attachment in your email.

The manual is 3.6 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info