798083
6
Zoom out
Zoom in
Previous page
1/16
Next page
EN-3 2205/B www.dimplex.eu
English IRP – Infra-red heating
Wall mounting
ATTENTION!
Do not install the device directly below a wall
socket.
Installation on wooden walls is permissible.
The heating device must be installed on a vertical wall
(see illustration). The minimum clearances must be
observed. In addition, a clearance of 500 mm is to be
maintained in front of the unit. All dimensions in mm.
Mark and drill the mounting holes for the bracket
and insert the dowels.
Screw bracket tight.
Mount heating device into bracket.
Ceiling mounting
The heating device must be installed on a horizontal
ceiling (see illustration).
If suspension from the ceiling is necessary, the “IRP
cable set” accessory must be used.
Dimensions x and h are recommendations for ensur-
ing a pleasant distribution of heat and can be adjusted
if required (observe the minimum clearances).
3. Electrical connection
The voltage specified on the type plate must match
the line voltage.
It is recommended that a separate electric circuit be
provided for the power supply.
The heating device is designed for fixed connection to
a wall socket. When mounting on a wall, route the de-
vice connection cable downwards.
The device must only be installed and repaired by a
qualified electrician in accordance with the applicable
safety regulations.
Connection may only take place on securely routed
cables!
A disconnecting device with a contact opening of at
least 3 mm at each pole (e.g. circuit breaker) must be
provided in the permanently installed wiring.
4. Heating operation
NOTE
i
Only use the device for room heating within enclosed
rooms.
The heating device may only be
operated in conjunction with an external room ther-
mostat with the following functions:
electronically controlled week programme,
adaptive control of the heating start,
further energy-saving functions.
Please observe the operating instructions for the
room thermostat.
Recommended room thermostat: Dimplex DTB 2R


6


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Dimplex IRP300W at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Dimplex IRP300W in the language / languages: English, German, French, Italian, Polish as an attachment in your email.

The manual is 0.44 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info