798061
15
Zoom out
Zoom in
Previous page
1/24
Next page
5.9.4 - Resetting parameters
Resetting the parameters allows you to go back to the default
settings.
Go to the «Installer», menu and turn the dial to «Reset PAR.».
Enter
Select yes
reset par.
reset par.
yes
5.9.6 - Counters (meters)
The «Counters» menu shows the number of start-ups from the
heat pump and the electrical back-up.
In the «Installer», menu turn the dial to «counters».
COunters
- COunter N°1 :
Number of start-ups from
the heat pump
- COunter N°2 :
Number of start ups from
the electrical back-up
- COunter N°4 :
Accumulated heat pump
running time.
5.9.5 - Read data
The «READ DATA» menu shows you, in real time, the information
given by the sensors.
In the «Installer» menu, turn the dial to «display».
The temperature which is permanently displayed on the screen
is the set temperature and does not necessarily indicate the
temperature of the water immediately available in the tank.
Manual locking from the main screen
Manual locking is possible from the main screen without gaining
access through the «Installer» menu provided that locking
settings are not already in place.
To lock manually, press for 3 seconds.
Press for 3 sec
locking
pro = To lock access to menus with
temporary unlocking (300 seconds)
is possible by pressing for
3 seconds, and then and
buttons for 3 seconds.
Enter
Select yes
500C
unlock.
no
Press for
3 sec
Enter
Select yes
500C
unlock.
no
unlock
yes
Press for
3 sec
Press for 3 sec
AUTO = To lock menu access with temporary unlocking (60
seconds) press for 3 seconds.
•When locking is activated, it is only possible to access unlocking
and to reset the alarm.
Display Description Reference on
electronics
board
water Domestic hot water
temperature in lower part of
tank
Teau
air Temperature of heat pump air
intake Tair
evap Temperature of heat pump
evaporator (expansion valve
outlet)
Tdegiv
mode pv (deactivated) factory settings
shedding O-peak hours switch
(0-on; 1- o)
heures
creuses
fan
contr.
Fan control switch
(0-on; 1- o)
hygrostat
mode pv (activated)
pv eco Contact input 1
(0-open; 1- closed)
1
pv max Contact input 2
(0-open; 1- closed)
2
- INSTALLER HEAT PUMP WATER HEATER 200 -270L AIR D/2 - MANUAL - 15
15


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Dimplex Edel 200 AIR D-2 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Dimplex Edel 200 AIR D-2 in the language / languages: English as an attachment in your email.

The manual is 2.49 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Dimplex Edel 200 AIR D-2

Dimplex Edel 200 AIR D-2 User Manual - Dutch - 48 pages

Dimplex Edel 200 AIR D-2 Installation Guide - Dutch - 48 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info