If any of these points have been neglected
or if the water quality did not allow correct
treatment within the legal framework the
warranty will be null and void.
Use of a recirculation pump should be
avoided. Recirculating can cause a lack
of hot water and overconsumption of
energy. If using a recirculation pump, the piping
should be insulated and the pump should be
controlled by a timer or another system which
will prevent domestic hot water from circulating
continuously.
domestic hot water circuit:
- copper
- stainless steel
- brass
- plastic
If the materials used in the domestic hot water
circuit are incompatible, corrosion damage may
occur.
Consequently, the appliance should always be connected to copper
domestic hot water pipes with a cast-iron or steel link, or with
dielectric connections (not supplied) to avoid an iron/copper
galvanic bridge.
Thoroughly ush the supply line piping before connecting the
appliance to the domestic installation so as not to introduce any
particles, metallic or other, into the appliance.
• Respect the standards in eect in the country of use, notably
hydraulic regulations and pressure safety regulations.
The appliance must operate with water between 12oF and 30oF.
With particularly hard water (TH>25oF) it is advised to use a water
softener.
• If any of these points have been neglected the warranty will be
null and void (values given are for water at a temperature of
20oC). (See DTU-60-1 for more information).
1. Stop valve
2. Pressure reducing valve
3. Check- valve
4. Insulating dielectric sleeve (not
supplied)
5. Pressure relief membrane valve (not
supplied)
7. Run-o siphon
8. Domestic water expansion vessel
9. Thermostatic mixing valve
10. Drainage valve
- The condensates tube should not be directly connected to a
drain. It must lead o into open air in a siphon which has been
added and contains water.
- Do not use a lip seal.
- Do not use an elbow on the exible hose.
4.4 - Condensates drainage
Resistivity <2200 Ωcm or <4500Ωcm
Complete
alkalimetric title
<1.6 meq/l <8OF
CO2<15 mg/l
Calcium (Ca++) <1.6 meq/l <8OF
Sulfates (SO4
--) >2 meq/l <10OF
Chlorides (Cl-) >2 meq/l <10OF
Sulfates and
Chlorides(SO4
--+Cl-)>3 meq/l <15OF
- INSTALLER HEAT PUMP WATER HEATER 200 -270L AIR D/2 - MANUAL-
8
8


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Dimplex Edel 200 AIR D-2 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Dimplex Edel 200 AIR D-2 in the language / languages: English as an attachment in your email.

The manual is 2.49 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Dimplex Edel 200 AIR D-2

Dimplex Edel 200 AIR D-2 User Manual - Dutch - 48 pages

Dimplex Edel 200 AIR D-2 Installation Guide - Dutch - 48 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info