EN
Technical data
DEE 1803 DEE 2103 DEE 2403
Rated output
[kW] 18 21 24
Rated voltage
[V] 400 400 400
Fuse protection
[A] 32 32 40
Minimum conductor cross-section
[mm
2
]4 4 6
Warm water flow at rated output
with temperature increase from
12 °C to 38 °C [l/min] 9.9 11.6 13.6
12 °C to 60 °C [l/min] 5.4 6.3 7.2
Start-up flow
[l/min] 2.6 2.6 2.6
Start-up flow pressure *
[MPa (bar)] 0.025 (0.25) 0.025 (0.25) 0.025 (0.25)
Application area in water specific electric
resistance at 15 °C
[Ωcm] ≥ 1 300 ≥ 1 300 ≥ 1 300
Rated pressure
[MPa (bar)] 1.0 (10.0) 1.0 (10.0) 1.0 (10.0)
Maximum permissible supply temperature
[°C] 20 20 20
Maximum mains impedance at connection point
[Ω] ≤ 0.400 ≤ 0.400 ≤ 0.400
* The pressure loss on the mixer must also be added.
A
If the continuous-flow heater does not have sufficient
water flow due to low water line pressure in your do-
mestic plumbing system, remove the flow-rate
limiter.
B
Priority circuit for the combination with electrical
storage heaters:
For operation with a priority circuit, a special load
shedding relay BZ 45L20 (special accessory) is re-
quired. Other existing load shedding relays, with the
exception of electronic load shedding relays, may
malfunction.
C
The control electronics must be coded when operated
with a load shedding relay.
Special accessories
Pipe kit DLE 02RBS: for use of the continuous-flow heater
as an under sink appliance
Priority switch (load shedding relay): for operation with
a priority circuit
Mounting kit
DLE 02AP: for surface mount installation
D
Status display on the appliance
LED Appliance status
Off Off
Lights up Ready
Slow flash (1/s) Appliance is heating
Fast flash (4/s) Desired water temperature is not
reached (water flow too high for
appliance rating).
E
The filter upstream from the check valve in the cold
water supply inlet is clogged.
Remove the filter and either clean it or descale it.
See Figure E 1–3.
472
236
20
100
332
42
388
124
137
G
1
2
A
15


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Dimplex DEE 2103 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Dimplex DEE 2103 in the language / languages: English, German, Dutch, French, Polish as an attachment in your email.

The manual is 3,27 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info