6. Return the tank to the sump, with the tank cap facing down and - see Fig. 10.
7. Gently place the metalbed back into position.
CLEANING
WarningAlways press Switch ‘A to the ‘OFF’ (0) position - see Fig. 11 and disconnect from the power supply before
cleaning the re.
We recommend cleaning the following components once every 2 weeks, particularly in hard water areas:-
Water Tank, Sump, Nozzle, Tank cap and seal, Air lter.
For general cleaning use a soft clean duster – never use abrasive cleaners.
To remove any accumulation of dust or uff, the soft brush attachment of a vacuum cleaner should occasionally be
used.
Water tank
1. Lift the metalbed and place carefully on the table/worktop - see Fig. 3.
2. Remove the water tank, as described earlier - see Fig. 6, put into sink , unscrew cap anti-clockwise - see Fig. 9
and empty water.
3. Using the supplied brush gently rub the inside surfaces of the cap, paying particular attention to the rubber ring in
the outer groove and the centre rubber seal.
4. Put a small quantity of washing up liquid into the tank, ret the cap and shake well, rinse out until all traces of
washing up liquid are gone.
5. Rell with decalcied/ltered tap water only, replace the cap (clockwise) , do not overtighten - see Fig. 10.
6. Gently place the metalbed back into position.
Sump
1. Lift the metalbed and place carefully on the table/worktop - see Fig. 3.
2. Press Switch ‘A’ to the ‘OFF’ (0) position -
3. Remove the water tank by lifting upwards and outwards - see Fig. 6.
4. Remove the nozzle by unclipping (1) and lifting upwards (2) - see Fig. 7
5. Disconnect the transducer (1) and feed/pull the connector underneath the LED’s (2) - see Fig. 15.
6. Gently lift up the sump, taking care to keep level so as not to spill any water. Sit the assembly in the sink.
7. Lift out the transducer and carefully tilt, so that the liquid drains out of the sump.
8. Put a small amount of washing up liquid into the sump, and using the supplied brush, gently clean all surfaces in the
sump and gently clean the transducer including the metal discs located in the top grooved surface - see Fig. 16.
10. When cleaned, thoroughly rinse the sump with clean water to remove all traces of washing up liquid.
11. Clean the Nozzle with the brush and ush out thoroughly with water - see Fig. 17.
12. Reverse the above steps to reassemble.
Air lter
1. Lift the metal bed and place carefully on the table/worktop - see Fig. 3.
2. Gently slide the air lter upwards out of its plastic holder - see Fig. 12.
3. Gently rinse with water in the sink and dry with fabric towel before returning.
4. Replace the lter making sure that the coarse black lter is facing the front of the re.
5. Gently place the metalbed back into position.
4
Additional Information
AFTER SALES SERVICE
Your product is guaranteed for 2 years from the date of purchase. Within this period, we undertake to repair or
exchange this product free of charge (excluding transducer disc, subject to availability & lifetime subject to regular
maintenance) provided it has been installed and operated in accordance with these instructions. Your rights under this
guarantee are additional to your statutory rights, which in turn are not affected by this guarantee.
RECYCLING
For electrical products sold within the European Community - At the end of the electrical products useful life
it not be disposed of with household waste. Please recycle where facilities exist. Check with your Local
Authority or retailer for recycling advice in your country.
PATENT / PATENT APPLICATION
Products within the Optimyst range are protected by one or more of the following patents and patent applications:
Great Britain GB 2402206, GB 2460259, GB 2460453 , GB 2418014, GB 2465738, GB 2449925, GB 2465537 , GB
2455277 , GB1020534.2, GB1020537.5, GB1110987.3
9


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Dimplex CAS250 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Dimplex CAS250 in the language / languages: English, German, Dutch, French, Italian, Polish as an attachment in your email.

The manual is 1,7 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info