9.7.2.3 RS (room sealed) connection
The appliance is provided with a flue ring. It should be attached air-tight (room sealed) to your flue duct.
A room sealed connection can be made in the following ways:
Fixed connection: When making a fixed connection, the flue material must be connected air-tight to the flue
ring. Do this with the aid of heat resistant paste.
Flexible connection: When making a flexible connection, the flexible tube must be connected air-tight to
the flue ring using the heat resistant paste.
In case of a flexible connection, proceed as follows (see appendix 2, fig. 5a to 5c):
Ø
Remove the flame baffle plate.
Ø
Disassemble the connecting piece by loosening the 3 nuts from the inside.
Ø
Pull the flexible pipe through the chimney.
Ø
Fix the draining flex/fix connecting piece to the flexible pipe, using 3 self-tapping screws.
CAUTION!
Apply heat resistant paste between the connecting collar and flexible hose for an air-tight connection.
Ø
Push the flexible pipe including the connecting piece back in the chimney.
Ø
Slide the fire into place.
Ø
Insert a hand through the flue hole and grasp the connecting piece handle.
Ø
Pull the flexible pipe with the connecting piece downwards.
Ø
Fasten the flexible connecting piece to the appliance with 3 bolts.
Ø
Mount the flame baffle plate.
!Caution
The handle in the flexible connecting piece (see appendix 2, fig. 5b) can be broken out after installation. This is not
necessary but can be desirable for sweeping the chimney.
9.7.2.4 Interior lining
9.7.2.4.1 Vermiculite
The fire’s vermiculite plates are located on the bottom against the side walls of the appliance. In the following
situations the vermiculite plates must be taken out:
When disassembling the air slide valve (see section 9.7.2.1).
To be able to reach the adjustable legs (see section 9.6).
When replacing the vermiculite plates.
The bottom plates are first removed and the side plates last. The insertion of the vermiculite plates takes place in
reverse order.
!Caution
Make sure that the vermiculite plates are replaced in the original position!
9.7.2.4.2 Flame baffle plates
On delivery the flame baffle plates (see appendix 2, fig. 23) are located in the top section of the appliance. The
flame baffle plates must be removed in a number of situations:
when mounting and checking the flue gas exhaust connection;
when performing maintenance at the flue duct;
when replacing the flame baffle plates.
For removing the flame baffle plate, proceed as follows:
!Caution
Follow the instructions below. Then repeat these instructions on the other side of the appliance.
Ø
Lift the left side of the flame baffle plate until it gets above the edge and slide the flame baffle plate to the right.
Ø
Lower the left side of the flame baffle plate and slide the flame baffle plate to the left.
Ø
Slide the right-hand side of the flame baffle plate over the edge.
Ø
Slide the flame baffle plate to the left and lower it until it reaches the lower section of the appliance.
Ø
Now you can remove the flame baffle plate.
Placing the flame baffle plate takes place in reverse order.
!Caution
The stainless steel profile must be placed at the front with the screw heads on top (see appendix 2, fig. 23).
45
45


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Dik Geurts Instyle 1000 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Dik Geurts Instyle 1000 in the language / languages: English, German, Dutch, French as an attachment in your email.

The manual is 3.54 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Dik Geurts Instyle 1000

Dik Geurts Instyle 1000 User Manual - English, German, Dutch, French - 64 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info