24 VIII User Manual Pedelec Xion
In the as-delivered condition, the battery is not
lly charged and is in what is referred to as
sleep mode. Sleep mode minimises the rate at
which the battery discharges itself. If the bat-
tery is allowed to discharge unchecked for an
extended period this can lead to total discharg-
ing which damages the battery. To “wake up” the
battery, simply charge it up again.
If you are having problems with the battery,
charge it for one minute initially. A reset occurs,
during which the battery management disables
sleep mode, for example. Aer this, the battery
will work again.
Ideally you should charge the battery at a tem-
perature of between +10°C and +30°C. It takes
longer to charge the battery at low temperatures,
while the battery will not charge up at tempera-
tures higher than +45°C. Ideally, you should
charge and store the battery inside your house or
in a warm garage when the outside temperature
is low. In this case you should only t the battery
on your bike just before using it.
If you are transporting your Pedelec by car, take
the battery out of its holder and transport it
separately.
The battery should ideally be stored for longer
periods with a charge state of 50% to 75% at a
temperature of +10°C.
7.3 Straightforward storage
If you do not need your battery for a while, store it
at a temperature of +10°C at three quarters of its
ll charge capacity.
The battery management switches the battery to
sleep mode to prevent a so-called total discharge.
This can occur aer dierent lengths of time with-
out being used. Depending on the charge state
of the battery, this can occur earlier with a lower
charge and later with a higher charge. The mana-
gement system activates the sleep mode aer
48hours without using the battery. The system
exits sleep mode when you press the button with
LED on the battery.
These benets are available due to highly eective
battery management that has been adapted to this
specic application and by tuning the battery for
operation with a 250 watt motor.
Observe the following points to increase the service
life of your Pedelec battery:
Make sure that the battery is lly charged before
you ride your bike for the rst time or if you have
not used it for a while.
If you continuously run the battery to empty
during normal operation, this reduces its ser-
vice life. If you partially recharge the battery
equently during normal operation, this has a
favourable eect on its service life.
You should therefore partially recharge the
battery whenever possible: Try not to run the
battery all the way down to empty and recharge
it even aer a short period of operation.
Charging times at dierent temperatures
Battery may be
damaged
Optimum temperature
range for charging
operation
Long charging times
-10°C 0°C 10°C 20°C 30°C 40°C 50°C
57


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Derby Cycle Pedelec Xion 2013 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Derby Cycle Pedelec Xion 2013 in the language / languages: English, German, Dutch, French, Italian, Spanish as an attachment in your email.

The manual is 19,8 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info