7
Check the plate for the type of refrigerant gas used
in your appliance.
Specic information regarding appliances with
R410A refrigerant gas
R410 is a refrigerant gas that complies with EC ecology regula-
tions. Do not puncture the refrigerant circuit on the appliance.
Environmental information: This unit contains uorinated
greenhouse gases covered by the Kyoto Protocol. Maintenance
and disposal must only be performed by qualied personnel
(R410A, GWP=2088).
Specic information regarding appliances with
R290 refrigerant gas
Thoroughly read all of the warnings.
When defrosting and cleaning the appliance, do not
use any tools other than those recommended by the
manufacturing company.
The appliance must be placed in an area without any
continuous sources of ignition (for example: open ames,
gas or electrical appliances in operation).
Do not puncture and do not burn.
Refrigerant gases can be odourless.
The appliance must be installed, used and stored in an area
that is greater than 15 m
2
.
This appliance contains 300 g of R290 refrigerant gas.
R290 is a refrigerant gas that complies with the European
directives on the environment. Do not puncture any part of
the refrigerant circuit.
If the appliance is installed, operated or stored in a non-
ventilated area, the room must be designed to prevent the
accumulation of refrigerant leaks resulting in a risk of re
or explosion due to ignition of the refrigerant caused by
electric heaters, stoves, or other sources of ignition.
The appliance must be stored in such a way as to prevent
mechanical failure.
Individuals who operate or work on the refrigerant
circuit must have the appropriate certication issued by
an accredited organisation that ensures competence in
handling refrigerants according to a specic evaluation
recognized by associations in the industry.
Repairs must be performed based on the recommendations
from the manufacturing company.
Maintenance and repairs that require the assistance of
other qualied personnel must be performed under
the supervision of an individual specied in the use of
ammable refrigerants.
WARRANTY AND TECHNICAL ASSISTANCE
Warranty and technical assistance conditions are indicated in the
documentation provided with your appliance.
TECHNICAL DATA
Power supply See characteristic plate
Max absorbed power
in air conditioning
Refrigerant
Cooling capacity
Limit operating conditions:
Temperature in the room
being cooled 21 ÷ 35°C
Disposal of the appliance
The appliance must not be disposed of with household
waste but taken to an authorised waste separation and
recycling centre.
Electrical Connection
Before plugging into the mains, check the following:
the mains voltage is the same as that indicated on the plate
on the back of the appliance;
the socket and electrical line are sized to support the load
required;
the socket is the proper type for the plug, otherwise, re-
place the socket;
the socket is connected to an ecient earthing system. The
manufacturer is not responsible in the event of non-com-
pliance with these injury prevention standards.
The power cable must only be replaced by special-
ised technicians.
Downloaded from www.Manualslib.com manuals search engine
8


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for DeLonghi Pinguino PAC EX120 SILENT at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of DeLonghi Pinguino PAC EX120 SILENT in the language / languages: English as an attachment in your email.

The manual is 2,37 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of DeLonghi Pinguino PAC EX120 SILENT

DeLonghi Pinguino PAC EX120 SILENT User Manual - English - 36 pages

DeLonghi Pinguino PAC EX120 SILENT User Manual - German - 15 pages

DeLonghi Pinguino PAC EX120 SILENT User Manual - Dutch - 9 pages

DeLonghi Pinguino PAC EX120 SILENT User Manual - French, Spanish - 36 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info