Troubleshooting
PROBLEM CAUSE REMEDY
The air conditioner
does not come on
there is no current
it is not plugged into the mains
The safety device has tripped
wait
plug into the mains
Contact your service centre
The air conditioner
works for a short
time only
the air exhaust hose has a constriction
the air exhaust hose is blocked
there are bends in the air exhaust hose
position the exhaust hose cor-
rectly
check there are no obstacles
obstructing air discharge
eliminate the bends
The air conditioner
works, but does not
cool the room
window open
there are heat sources in the room (burner,
lamp, etc)
ithe exhaust hose is detached
air filter clogged
the air conditioner is not powerful enough for
the conditions or size of the room
close the window
eliminate the heat source
connect the exhaust hose
•clean or replace the filter
•clean or replace the filter
Particular odour in
the room
the filter is clogged
The air conditioner
does not operate
for about 3 minutes
after turning it on
The safety device has tripped wait for three minutes
// PP FF //
appears
on the display
See self-diagnosis section
WARNING - THIS APPLIANCE MUST BE EARTHED
IMPORTANT
The wires in the mains lead are coloured in accordance with the following
code:
Green and yellow: Earth
Blue: Neutral
Brown: Live
As the colours of the wires in the mains lead may not correspond with the
coloured markings identifying the terminals in your plug, proceed as fol-
lows:
The green and yellow wire must be connected to the terminal in the plug
marked with the letter E or the earth symbol or coloured green or
green and yellow.
The blue wire must be connected to the terminal marked with the letter N
or coloured black.
The brown wire must be connected to the terminal marked with the letter L
or coloured red.
ELECTRICAL CONNECTION (UK ONLY)
A) If your appliance comes fitted with a plug, it will incorporate a 13
Amp fuse. If it does not fit your socket, the plug should be cut off from
the mains lead, and an appropriate plug fitted, as below.
WARNING: Very carefully dispose of the cut off plug after removing
the fuse: do not insert in a 13 Amp socket elsewhere in the house as
this could cause a shock hazard.
With alternative plugs not incorporating a fuse, the circuit must be
protected by a 15 Amp fuse.
If the plug is a moulded-on type, the fuse cover must be re-fitted when
changing the fuse using a 13 Amp Asta approved fuse to BS 1362.
In the event of losing the fuse cover, the plug must NOT be used until
a replacement fuse cover can be obtained from your nearest electri-
cal dealer. The colour of the correct replacement fuse cover is that as
marked on the base of the plug.
B) If your appliance is not fitted with a plug, please follow the instruc-
tions provided below:
14


Need help? Post your question in this forum.

Forumrules
1

Forum

delonghi-pac-c110

Reset search

  • Bought this pac c110 2nd hand. It works ice cold well and after wait water pours out the bottom tube. Exhaust pipe is clear. Filter is clean please advise me what next to do reach me on preceelala@gmail.com Submitted on 21-7-2021 at 16:31

    Reply Report abuse
  • Bought this pac c110 2nd hand. It works ice cold few a few minutes then just warm air. Sometimes water pours out the bottom tube. Exhaust pipe is clear. Filter is clean. What's wrong? Does it need recharged like a car? Thanks Derek
    Degsey11@hotmail.com Submitted on 26-6-2020 at 17:44

    Reply Report abuse


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for DeLonghi pac c110 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of DeLonghi pac c110 in the language / languages: English as an attachment in your email.

The manual is 0,9 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of DeLonghi pac c110

DeLonghi pac c110 User Manual - German - 15 pages

DeLonghi pac c110 User Manual - Dutch - 15 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info