608088
10
Zoom out
Zoom in
Previous page
1/20
Next page
10
UNO/2 200, 300, 400, 500 - UNO/1 200, 300, 400, 500 06/02/12 - 300024525-001-B
5 Diemasol A solar regulator
5.1 General description of how the unit operates
In automatic mode, the Diemasol A regulator operates in accordance
with the following principles:
` The sun's rays heat the transfer fluid in the collector. For the
regulation process to be triggered, a minimum temperature of
30 °C is required in the collector and there must be a
temperature difference of 10 K by comparison with the tank.
` During the AUTO-calibration stage which follows (tu parameter
setting tu, factory setting 1 minute) the PUMPE (relay) operates
to its full extent (100%).
` Subsequently, the solar pump regime is calculated dynamically
depending on a difference between the reference temperature
(parameter DT, factory setting 20 K) and the calorifier
temperature.
` Depending on the heat available, the system heats up the solar
tank and cuts off when the tank storage temperature is reached
(adjustment parameter SX, factory setting: 60 °C).
` When the temperature in the collectors reaches the maximum
value (adjustment parameter CX, factory setting 100°C), the
solar pump is triggered to cool the collectors. The pump
continues to operate until the temperature in the collectors is
lower than 5 K at parameter CX and/or the maximum storage
temperature (80°C) is reached in the hot water storage tank.
Regulation goes into cooling mode if the preparer tank
temperature is exceeded. As soon as the temperature in the
collectors drops below the temperature in the calorifier, the
calorifier is cooled down to its set temperature. The installation
is thus protected against overheating and repeated stoppages,
allowing thus the prolonged absence of the user even in the
summer period.
5.2 Start-up
%
If the temperature in the solar collectors is higher
than 130°C, the control system operates in safety mode.
Wait until the evening before start-up or cool down (cover)
the solar collectors.
Switch on the device. The regulator starts an initialisation phase
during which the LED flashes red and green. When initialisation is
complete, the regulator changes to automatic mode. The factory
settings for this mode give optimum performance with most
installations.
If special conditions make it necessary to change the settings, the
corresponding adjustment parameters can be reset.
M000392
M000391
10


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for De Dietrich INISOL - UNO-2 400 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of De Dietrich INISOL - UNO-2 400 in the language / languages: English as an attachment in your email.

The manual is 1,22 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of De Dietrich INISOL - UNO-2 400

De Dietrich INISOL - UNO-2 400 User Manual - Dutch - 12 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info