GT 530A DDR_G30A/AE _IO_V4.0 09/2013
Recommendations
The installation must be made in accordance with
codes in effect.
An expansion tank has to be connected to the
system Safety valve must be connected to the
boiler piping without any valve or stop installed
between the device and the boiler.
Pressure reducing valve and back ow preventer on
boiler make up water feed.
The boiler when used in connection with a
refrigeration system must be installed so the chilled
Filling
The boiler may be lled using the drain tap or water
make-up system.
Filling should be done at a slow ow rate in order to
purge all the air continued in the system through air
vents installed at the system high points lling is always
done with circulating pumps stopped.
medium is piped in parallel with the boiler with the
appropriate valves to prevent the chilled medium
from entering the boiler
The boiler piping system of hot water boiler
connected to heating coils located in the air
handing units where thy may be exposed to
refrigerated air circulation must be equipped with
ow control valves or other automatic means to
prevent gravity circulation of the boiler water
during the cooling cycle.
Installation Specications
Minimum Safety value Flow according to the maximum boiler output
_____________________________________________________________________________________ ______________________ _______________________________________________
Source: ASME Boiler and Pressure Vessel Code IV
16


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for De Dietrich GT 530A Series at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of De Dietrich GT 530A Series in the language / languages: English as an attachment in your email.

The manual is 13,03 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info