De Dietrich Gas 310/610 ECO
13.0 SETTING MODE
13.1 User level setting mode ()
Setting mode is used to change various settings to suit individual requirements. The required code is selected by
pressing the
key until appears in the code window. Select the required code with the key. Now press
the [+] key to increase a setting or the [-] key to decrease a setting.
Press the
key to stare the new setting. The new value will flash twice in the window to confirm the setting.
Cede
Description
Setting range and explanation if
necessary
Factory setting

Flow temperature set point (see
section 13.1.1)
 -  = 68194°F or
 -  [20-90°C]
Boiler operating limit set point, also maximum
setting if external control is used.
= 176°F
 = 80°C

Pump post
purge setting
(see section 13.1.2)
 = Pump post purge = 10 seconds

 -  = pump run on in minutes
 = Pump operates continuously

Boiler control
setting
(see section 13.1.3)
Control mode (modulating, on/off, etc.)

Important!! Changing and should only be 0n design engineer’s advice.
13.1.1 Flow temperature ()
The required flow temperature is adjustable from 68-194°F [20-90°C].
The following diagram shows a typical example of this procedure:
Table 17 Settings mode user level
Fig. 26 Setting flow temperature
53


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for De Dietrich Gas 610 ECO at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of De Dietrich Gas 610 ECO in the language / languages: English as an attachment in your email.

The manual is 3,76 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info