535594
116
Zoom out
Zoom in
Previous page
1/128
Next page
PowerScan™ PD8590-DPM Imager
Industrial Corded Handheld Bar Code Reader
Users Manual
Datalogic ADC, Inc.
959 Terry Street
Eugene, OR 97402
USA
Telephone: (541) 683-5700
Fax: (541) 345-7140
©2013 Datalogic, Inc.
An Unpublished Work - All rights reserved. No part of the contents of this documentation or the proce-
dures described therein may be reproduced or transmitted in
any form or by any means without prior
written permission of Datalogic ADC, Inc. or its subsidiaries or affiliates ("Datalogic" or “Datalogic ADC”).
Owners of Datalogic products are hereby granted a non-exclusive, revocable license to reproduce and
transmit this documentation for the purchaser's own internal business purposes. Purchaser shall not
remove or alter any proprietary notices, including copyright notices, contained in this documentation
and shall ensure that all notices appear on any reproductions of the documentation.
Should future revisions of this manual be published,
yo
u can acquire printed versions by contacting your
Datalogic representative. Electronic versions may either be downloadable from the Datalogic website
(www.datalogic.com) or provided on appropriate media. If you visit our website and would like to make
comments or suggestions about this or other Datalogic publications, please let us know via the "Contact
Datalogic" page.
Disclaimer
Datalogic has taken reasonable measures to provide inf
ormation in
this manual that is complete and
accurate, however, Datalogic reserves the right to change any specification at any time without prior
notice.
Datalogic and the Datalogic logo are registered trademarks of
Data
logic S.p.A. in many countries, includ-
ing the U.S.A. and the E.U. PowerScan is a registered trademark of Dat
alogic ADC, Inc. in many countries,
including the U.S.A. and the E.U. All other brand and product names may be trademarks of their respec-
tive owners.
POWERSCAN D8590 User’s Manual i
Introduction
Table of Contents
Chapter 1 Quick Start
Check Required Hardware ...................................................................... 1-2
USB Interface .......................................................................................... 1-3
RS-232 Interface ..................................................................................... 1-4
Install ESP ............................................................................................... 1-5
Select Model............................................................................................ 1-6
Select Protocol and
Connect to Imager................................................... 1-7
Chapter 2 Using ESP
EZ Mode ..................................................................................................2-2
Application Mode ..................................................................................... 2-4
Tree Controls........................................................................................... 2-5
Menu Toolbar .......................................................................................... 2-6
Send/Receive ....................................................................................... 2-16
Chapter 3 Basic Operations
Targeting and Decoding .......................................................................... 3-2
Scanning Guidelines................................................................................3-3
Decode Zones and Lighting Zones.......................................................... 3-4
Illumination System
................................................................................. 3-7
Illumination Sequence ............................................................................. 3-9
Chapter 4 Communications
Communications by ESP......................................................................... 4-2
Communications Overview...................................................................... 4-3
USB Interface .......................................................................................... 4-4
RS-232 Interface ..................................................................................... 4-5
Preamble ................................................................................................. 4-7
Postamble................................................................................................ 4-9
Preamble and Postamble by ESP ......................................................... 4-11
Keyboard Mapping ................................................................................ 4-12
Text Commands .................................................................................... 4-13
Other Communications Settings in ESP................................................ 4-14
Chapter 5 Read Cycle
Read Cycle by ESP ................................................................................. 5-2
Button Stay-Down Time...........................................................................5-3
Ignore Duplicate Symbol Timeout ........................................................... 5-4
Region of Interest ....................................................................................5-5
Chapter 6 Symbologies
Symbologies by ESP ............................................................................... 6-2
Aztec........................................................................................................ 6-3
BC412...................................................................................................... 6-4
Codabar................................................................................................... 6-5
Code 39 .
..................................................................................................6-6
Code 93 ...................................................................................................6-7
ii POWERSCAN D8590 User’s Manual
Table of Contents
Code 128................................................................................................. 6-8
Composite ............................................................................................... 6-9
Data Matrix ............................................................................................ 6-10
GS1 DataBar ........................................................................................ 6-11
Interleaved 2 of 5................................................................................... 6-12
MicroPDF417 ........................................................................................ 6-13
PDF417 ................................................................................................. 6-14
Pharmacode .......................................................................................... 6-15
QR Code .............................................................................................. 6-17
UPC/EAN ............................................................................................. 6-18
Symbology Identifier................................
............................................. 6-19
Chapter 7 I/O Parameters
I/O Parameters by ESP ........................................................................... 7-2
Operational Feedback ............................................................................. 7-3
Gain Control ............................................................................................ 7-4
Exposure ................................................................................................. 7-5
Data Validation ........................................................................................ 7-6
Chapter 8 Advanced Operations
Dot Peen Enhanced Illumination Settings ............................................... 8-2
Illumination Settings by ESP ................................................................... 8-3
Lock Settings........................................................................................... 8-6
Chapter 9 Terminal
Terminal View.......................................................................................... 9-2
Find ......................................................................................................... 9-3
Send ........................................................................................................ 9-4
Macros..................................................................................................... 9-5
Terminal Right-Click Menu ...................................................................... 9-6
Terminal Dropdown Menu ....................................................................... 9-7
Chapter 10 Utilities
Device Control....................................................................................... 10-2
Differences from Default........................................................................ 10-3
Firmware ............................................................................................... 10-4
Advanced .............................................................................................. 10-6
Appendices
Appendix A General Specifications .........................................................A-2
Appendix B Electrical Specifications .......................................................A-4
Appendix C Default/Reset Procedure .....................................................A-7
Appendix D Maintenance ................................
........................................A-8
Appendix E Troubleshooting ...................................................................A-9
POWERSCAN D8590 User’s Manual iii
Introduction
About the POWERSCAN D8590
The key features of the POWERSCAN D8590 are:
Best-in-class DPM decode algorithms
Image Enhance optimization for difficult-to-d
ecode direct part marks
LED targeting pattern
USB and RS-232 interface options
Fast processing
Rugged design
Sustains 50+ drops from six
fe
et to concrete
About This Manual
This manual provides complete information on setting up, installing, and configuring the
POWERSCAN D8590. The chapters are presented in the order in which the imager would
be assembled, configured, and optimized.
Highlighting
Cross-references and web addresses are highlighted in blue bold.
References to ESP, its to
olbar headings (Communications, Symbologies, I/O Parameters,
etc.) and menu headings are highlighted in Bold Initial Caps.
iv POWERSCAN D8590 User’s Manual
Statement of Agency Compliance
Statement of Agency Compliance
The POWERSCAN D8590 has been tested for compliance with FCC regulations and was
found to be compliant with all applicable FCC Rules and Regulations.
IMPORTANT NOTE: To comp
ly with FCC RF exposure compliance requirements, this
device must not be co-located or operate in conjunction with any other antenna or transmitter.
CAUTION: Changes or modifications not expressly approved by the party responsible for
compliance could void the users authority to operate the equipment.
The POWERSCAN D8590 has been tested for compliance to CE (Conformité Européenne)
standards and guidelines and was found to conform to applicable CE standards, specifically
the EMC requirements: EN 55024, ESD EN 61000-4-2, Radiated RF Immunity EN 61000-4-3,
EFT EN 61000-4-4, Surge EN 61000-4-5, Conducted RF Immunity EN 61000-4-6, Magnetic
Field Immunity EN 61000-4-8, Voltage Dips EN 61000-4-11, Emissions EN 55022, Class B
Radiated Emissions, and Class B Conducted Emission, Current Harmonic Emissions IEC
61000-3-2, Voltage Fluctuation and Flicker IEC 61000-3-3 Class B.
POWERSCAN D8590 User’s Manual 1-1
1 Quick Start
Contents
This section is designed to get your POWERSCAN D8590 up and running quickly so you
can get a sense of its capabilities and test sample symbols. Detailed setup information for
configuring the imager for your specific application can be obtained in the subsequent
sections.
Your interface type will determine how data is r
eceived by your host. When
sending data by
USB, you must open a text editor in your host computer. When sending data serially, you
must use a terminal program such as HyperTerminal or
ESP
’s
Terminal
view (RS-232 only).
Check Required Hardware ........................................................................................................... 1-2
USB Interface ............................................................................................................................... 1-3
RS-232 Interface .......................................................................................................................... 1-4
Install ESP.................................................................................................................................... 1-5
Select Model................................................................................................................................. 1-6
Select Protocol and Connect to Imager........................................................................................ 1-7
1-2 POWERSCAN D8590 User’s Manual
Check Required Hardware
Check Required Hardware
Parts List for USB POWERSCAN D8590:
One POWERSCAN D8590 imager
One 12 ft. USB cable (pre-attached to imager)
Parts List for RS-232 POWERSCAN D8590:
One POWERSCAN D8590 imager
Cable clip attachment
Spacer
Two threaded screws
RS-232 Interface Kit
– 8 ft. coiled R-232 cable
– Power supply (U.S., Euro, or UK)
Quick Start
POWERSCAN D8590 User’s Manual 1-3
USB Interface
Note: The USB interface draws its power from the host.
USB Configuration
Installation Steps for USB
1. Connect the USB cable to the host.
2. Open any program in your host computer
that can receive keyboard text, such as
Notep
ad.
3. Read the Rese
t to USB F
actory
Defaults symbol below:
Reset to USB
Factory Defaults
4. Read the Save Settings symbol.
Save
Settings
Test Symbol
(ABCDEFGHIJKLMNOP)
Item Description Part Number
1 POWERSCAN D8590 DPM Imager, USB PD8590-DPM
2 USB Cable Included
USB Configuration
1-4 POWERSCAN D8590 User’s Manual
RS-232 Interface
RS-232 Interface
Note: Unlike USB, the RS-232 interface does not draw its power from the host computer.
RS-232 Configuration
Installation Steps for RS-232
1. Power-off the host.
2. Connect the 8-pin mini-DIN on the
cable to th
e POWERSCAN D8590.
3. Connect the 9-pin D-sub connector to
the
host com
puters serial port.
4. Connect the cable to the power supply.
5.
Plug in the power supply and power-on
the host.
6. Start up a terminal program (such as
ESP
’s
Terminal
view or HyperTerminal)
and set to 57.6K baud, 8 data bits,
none parity, and 2 stop bits.
7. Read the Rese
t to RS-
232 Factory
Defaults symbol below.
Reset to RS-232
Factory Defaults
8. Read the Save Settings symbol.
Save
Settings
Test Symbol
(ABCDEFGHIJKLMNOP)
Item Description Part Number
1 POWERSCAN D8590 DPM Imager, RS-232 PD8590-DPM
3
Kit, RS-232, 8’ coiled, US power supply CAB-532-KUS
Kit, RS-232, 8’ coiled, EU power supply CAB-532-KEU
Kit, RS-232, 8’ coiled, UK power supply CAB-532-KUK
RS-232 Configuration
Quick Start
POWERSCAN D8590 User’s Manual 1-5
Install ESP
Click on the ESP icon to run Datalogic ESP.
Note: Datalogic ESP can be installed from the Support Area at
www.datalogic.com.
ESP System Requirements
166 MHz Pentium processor (Pentium II processor recommended)
Windows Vista, XP, or 2000 operating system
Internet Explorer 5.0 or higher
64 MB minimum RAM (128+ MB RAM recommended)
80 MB hard drive space
800 x 600 minimum 256 color display (1024 x 768 32-bit color recommended)
Important: The imag
er must be in USB or RS-232 Mode to connect to ESP.
Save
Settings
1-6 POWERSCAN D8590 User’s Manual
Select Model
Select Model
When you start ESP, the following menu will appear:
If you need to select another model later, click Switch Model at the top of the screen.
1. Click the POWERSCAN D8590 button and then click OK. If you do not want to make
this selection every time you start ESP, uncheck “Show this dialog at startup”.
2. Select the default reader name (POWERSCAN D8590-1)
, or type a name of your
choice in the Description text field and click OK.
3. Click Yes when this dialog
appears:
Quick Start
POWERSCAN D8590 User’s Manual 1-7
Select Protocol and Connect to Imager
USB (Standard)
In the Select Protocol dialog box, select the communications protocol you are using
and click Next.
From the default USB settings, click the
Switch Mode button to connect to the
reader in USB HID Mode.
Print the USB Connect Mode symbol (also shown in the Install ESP step) and decode
it with the imager to ensure that you are in the correct communications mode. Keep the
printed symbol in a convenient place for future use.
Click Next when
you are finished.
The USB Select De
vice dialog will then reappear:
Reader ID number should match
the serial number on the base of
the imager.
You will see a “Reader ID” number in the USB Select Device field. Click Connect.
When you are connected successfully, the CONNECTED message will appear in
a
green box in the status bar at the bottom right of the screen.
You are now ready to configure your imager using ESP. Subsequent sections provide
more detailed information about ESP’s configuration options.
1-8 POWERSCAN D8590 User’s Manual
Select Protocol and Connect to Imager
RS-232 Option
Select RS-232 and click the Show Connect Symbol button.
•Print the RS-232 Connect Mode symbol (also shown in the Install ESP step) and
decode it to ensure that you are in the correct communications mode. Keep the printed
symbol in a convenient place for future use.
Click Next to return to the RS-232 dia
log.
Configure RS-232 settings and COM port and click Connect
.
When you are connected successfully, the CONNECTED message will appear in a
green box in the status bar at the bottom right of the screen.
If the connection attempt fails, enable a different communications port, check your port
connections, and try again.
You are now ready to configure your imager using ESP. Subsequent se
ctions provide
more detailed information about ESP’s configuration options.
POWERSCAN D8590 User’s Manual 2-1
2 Using ESP
This section is designed to help you understand the structure and application of ESP.
When you open ESP, unless otherwise specified in the ESP Preferences dialog acce
ssible
from the Options heading on the menu toolbar, you will enter EZ Mode for initial setup.
From there, you can enter Application Mode (App Mode) and access several configuration
menus (Communications, Read Cycle, Symbologies, I/O Parameters, a Terminal
interface, and a Utilities interface).
ESP ca
n be used to configure the POWERSCAN D8590 in the following ways:
Tree Controls: Each con
figuration menu contains a list of all option settings that pertain
to that specific element of imager operation. For example, the Communications menu
shows a Communications Mode command, and then the options RS-232 Serial, USB
Keyboard, and USB Native (HID), all of which are accessible from a dropdown menu.
Gra
phic User Interfaces: Settings can be
configured using such point-and-click tools
as radio buttons, tabs, spin boxes, check boxes, and drag-and-drop functions.
Terminal:
ESP
’s
Terminal
interface allows you to send configuration and utility commands
directly to the imager by typing them in the provided text field.
EZ Mode....................................................................................................................................... 2-2
Application Mode.......................................................................................................................... 2-4
Tree Controls................................................................................................................................ 2-5
Menu Toolbar ............................................................................................................................... 2-6
Send/Receive ............................................................................................................................ 2-16
2-2 POWERSCAN D8590 User’s Manual
EZ Mode
EZ Mode
The EZ Mode screen is the first thing you will see when you start ESP. EZ Mode will help
you get your imager up and running quickly, and will acquaint you with the ESP interface.
POWERSCAN D8590 User’s Manual 2-3
Using ESP
Image Quality
The video view in EZ Mode (and also on the Video tab in I/O Parameters) allows you to
capture images from the imager for further analysis. If Upload Images is checked and you
click the Start button, image captures will be uploaded automatically for every good read.
Images will also be uploaded for every no read, upon release of the imager’s trigger.
You can right-click on a captured image to bring up
the me
nu shown below. If you select
Store higher quality images, you will see a dropdown menu with JPEG 60% quality (small
size), JPEG 80% quality (full size), JPEG 100% quality (full size) and TIFF (full size).
The imagers illumination setup can be restored by clicking the Defa
ult box in the EZ
Mode view. Refer to the Basic Operations section for more information about the
imager’s illumination capabilities.
Note: If you have difficulty viewing TIFF images, it is recommended that you use Paint or
viewer software that is optimized for TIFF files.
Note:
TIFF images are large files and take significantly longer to download than JPEG images.
Right-click on the
image capture to
bring up this menu.
Note: Image size will vary depending on user settings for Region of Interest, and
whether or not Low Resolution Image is checked in the Illumination dialog in ESP
.
Image Save Mode Region of Interest Low Resolution Final Image Size
Small Size (Displayed) 1280 x 1024 No 320 x 256
Small Size 1280 x 1024 Yes 320 x 256
Small Size 800 x 600 No 400 x 296
Small Size 800 x 600 Yes 400 x 296
Full Size 1280 x 1024 No 1280 x 1024
Full Size 1280 x 1024 Yes 640 x 512
Full Size 800 x 600 No 800 x 600
Full Size 800 x 600 Yes 400 x 296 (JPEG); 400 x 300 (TIFF)
2-4 POWERSCAN D8590 User’s Manual
Application Mode
Application Mode
Application Mode gives you access to a robust configuration environment, including
tree controls that let you make precise changes to operation parameters, and graphic
interfaces that make configuring your imager easy and intuitive.
Menu
toolbar
Click on this icon to
return to this view from
Utilities or Terminal.
Click these tabs to access
configuration tree controls.
Click here
to open
Terminal.
Click here to
return to
EZ Mode.
Click here for Batch
Files and Firmware.
Click these buttons to
Send and Receive
commands or switch
reader models.
Assign Preamble and Postamble characters
using the simple interface shown above.
Note: For specific information on any of the icons shown above in the operations bar or
configuration bar, see corresponding sections.
POWERSCAN D8590 User’s Manual 2-5
Using ESP
Tree Controls
To make changes to configuration settings in the tree controls:
2. Double click on
the parameter and
click once in the
selection box to
view options.
3. Place your cursor
in the selection
box, scroll down to
the setting you
want to change
and click once on
the setting.
4. Left click again on the open screen to complete the
selection.
5. Right click on the open screen and select Save to
Reader to implement the command in the imager.
1. Left click on the +/-
to expand or collapse
the tree.
The imager must be in one of the modes below to communicate with ESP.
USB
Connect
Mode
RS-232
Connect
Mode
USB
RS-232
Save Settings
2-6 POWERSCAN D8590 User’s Manual
Menu Toolbar
Menu Toolbar
File > New
Whenever New is selected from the File menu, the default
configuration of ESP is loaded.
Open / Save
When Save or Save As is selected, the ESP configuration is
saved to the host computer’s hard drive and available whenever
the same file is selected under Open.
When you save menu changes to your hard drive, these
changes a
re not saved to your imager. The diagram below
shows how settings can be saved and received between ESP
and the imager, and ESP and the host hard drive.
(Save to Reader)
(Receive Reader
Settings)
Import / Export
Import converts the ASCII settings from a text file to ESP configuration settings.
Export converts the active ESP configuration sett
ings to an ASCII text file.
POWERSCAN D8590 User’s Manual 2-7
Using ESP
Model
The Model menu allows you to select between reader models. When you choose another
model, the current connection with your present model will be terminated.
New Model
To connect to another model, select New Model, choose the model you want, and click OK.
All models you have selected and enabled will continue to appear in the dropdown
model
menu. The New Model option is repeated when you click the Switch Model button on the
top row of icons.
2-8 POWERSCAN D8590 User’s Manual
Menu Toolbar
Options
You can use the Options menu to save memos and set up ESP preferences.
Preferences will be saved and loaded in
to ESP the next time ESP is opened, whether or
not you save the ESP file to the host computer.
Preferences > General Tab
Reload Last File
At startup, reloads the last file saved to the computer.
Show Model Prompt
At startup, remembers the last connected model and displays it in the Connecting...
dialog whenever you attempt to connect.
Show Connect Prompt
At startup, displays the Would you like to connect... prompt.
Receive After Connect
At startup, loads the imager’s settings into ESP. (This is not recommended if you want to
preserve your ESP settings for future use.)
Skip EZ Mode
At startup, skips EZ Mode and opens directly in App Mode.
Show Both Icon and Text
Sets the toolbar to display icons and names of all operations.
Only Show Icon
Sets the toolbar to display only icons representing operations, without text.
Only Show Text
Sets the toolbar to display names of operations only, without icons.
POWERSCAN D8590 User’s Manual 2-9
Using ESP
Terminal Tab
When
Show Non-Printable Characters
is checked, characters such as
‘CRLF’
will be displayed in the terminal
window. When the Enhanced Format
radio button is checked, subscript and
superscript formatting is shown.
When Dis
play incoming data even
when not in focus is checked, dat
a
from the imager will continue to
appear in the terminal even when
ESP is not the top window
on the host
computer’s screen.
When Enable Echo is checked, the
terminal window displays user-entered
data.
Change Keyboard Macros
Clicking the
Change Keyboard Macros
button brings up the Function Keys
dialog. In this dialog you can select the
desired function key and then enter
your macro keystrokes in the associated
key map. For example, to make Ctrl-F2
the keystroke to send a trigger character
,
select F2, then in the Ctrl row, enter
<trigger character>
and click
OK
.
Then whenever the
Ctrl-F2
keystroke
is
pressed, the trigger character will start
the read cycle.
Note: Th
e F1
key is reserved for opening ESP Help and the F3 key is reserved for the
Find Next function.
Change Font
Sets the font characteristics for data received from the imager.
Change Echo Font
Sets the font characteristics of user-entered data.
2-10 POWERSCAN D8590 User’s Manual
Menu Toolbar
Bar Code Options Tab
Sizing Information
Sets Bar Width (in mils) of symbols that can be created in ESP.
POWERSCAN D8590 User’s Manual 2-11
Using ESP
Advanced Tab
The Auto Sync dialog on the Advanced tab allows you to determine whether Auto Sync
will be automatically enabled in sections of ESP where it is used, or if it will ask you before
it enables Auto Sync functions.
Always Ask Before Auto Sync Occurs
If you check this option box, you are then able to determine what specific Auto Sync
functions will be enabled. Receive Settings from the Reader will automatically send
the imager’s settings to ESP when Auto Sync is enabled. Send ESP Settings to the
Reader will automatically send all imager configuration settings chosen in ESP to the
imager. Do Not Send or Receive Settings creates a condition in which Auto Sync will
not send imager settings to ESP, or send ESP settings to the imager.
Include Preamble and Postamble with Send Save
Sends Preamble and Postamble settings along with other settings when a Send and Save
is performed.
Send XON with Auto-Connect
Sends an
XON
(
Begin Transmission
) command to the imager before starting the
Auto-Connect
routine.
2-12 POWERSCAN D8590 User’s Manual
Menu Toolbar
Preferences > Advanced Tab (cont.)
Ask to Save ESP File when Quitting
When enabled, prompts the user to save a .esp file when ending a session.
The .esp file will be saved in the location specified by the user.
Connect to Readers via TCP/IP
When enabled, shows the TCP/IP Connection Wizard by default.
Use Default Storage Location
When enabled, automatically stores data in ESP’s Application Data folder.
POWERSCAN D8590 User’s Manual 2-13
Using ESP
Document Memo
The information you type in the Document Memo field will appear in a context-sensitive text
box whenever your cursor hovers over the Document Memo item on the Options menu.
Model Memo
Similar to Document Memo, the information you type in the Model Memo field will appear
in a context-sensitive text box whenever your cursor hovers over the Model Memo item on
the Options menu. Memos created in Model Memo are specific to the model enabled
when the message was created.
Note:
Memos must be saved in a
.esp
file if you want them to available in your next session.
If you do not save your current session, any memos that you have entered during the session
will be discarded, and will be unavailable in your next session.
2-14 POWERSCAN D8590 User’s Manual
Menu Toolbar
Connection Wizard
When you choose to connect to the imager via the Connection Wizard, you will first need
to select the correct protocol (see Select Protocol and Connect to Imager).
When you have successfully connected to the imager you will see one of
the two following
displays in the status bar at the lower right of the screen:
RS-232:
USB:
POWERSCAN D8590 User’s Manual 2-15
Using ESP
View
The options in the View menu correspond to icons on the operations
toolbar (Parameters, Setup, Terminal, Utilities). Each option
allows you to configure the imager or to perform various other
functions in the chosen view.
The Vi
ew menu also allows you to
access the Bar Code Dialog.
Bar Code Dialog
In the Bar Code Dialog you can directly type the text and commands
you want to encode. This allows you to create configuration symbols
that you can print and read with the imager.
2-16 POWERSCAN D8590 User’s Manual
Send/Receive
Send/Receive
To access Receive, Save, Default, and Advanced options, click the Send/Recv button.
You can also access these options by right-clicking in an
y of the configuration views.
Receive Reader Settings
From the Send/Recv menu, select Receive Reader Settings.
This option is useful if you want to receive the imager
s settings and save them as a file for
later retrieval. For example, if your imager has settings that you do not want to change,
choosing Receive Reader Settings will allow you to load those settings to ESP and save
them as an ESP file.
Receiving the imagers settings also assures
that you will not subsequently save any
unwanted configuration changes previously made in ESP.
Select this option if you want to upload the imager’s settings to ESP. For examp
le, if your
ESP file has a number of custom settings that you want to maintain and download to the
imager, you will lose those ESP settings if you choose to receive settings from the imager.
Save to Reader
Send, No Save
This saves ESP settings to current memory.
Send and Save
This activates all changes in current memory
and saves to the imager.
POWERSCAN D8590 User’s Manual 2-17
Using ESP
Default
When you select Default Current Menu Settings or Default all ESP Settings you are
only defaulting settings in
ESP
. The imager is not affected unless you download new settings.
Advanced Options
Send Current View
This is the same as Save
to Reader > Send No
Save except that only the
commands in the current
menu tree are sent.
Send Current
Command
This is the same as Send
Current View above, but
only saves the command
that is currently selected.
2-18 POWERSCAN D8590 User’s Manual
Send/Receive
NOTES
POWERSCAN D8590 User’s Manual 3-1
3 Basic Operations
Contents
This section explains how to practice targeting and triggering, and how to begin configuring
the imager.
Targeting and Decoding ............................................................................................................... 3-2
Scanning Guidelines..................................................................................................................... 3-3
Decode Zones and Lighting Zones............................................................................................... 3-4
Illumination System ...................................................................................................................... 3-7
Illumination Sequence .................................................................................................................. 3-9
3-2 POWERSCAN D8590 User’s Manual
Targeting and Decoding
Targeting and Decoding
The POWERSCAN D8590 features simple blue targeting LEDs to indicate optimal read range.
1.
Hold the imager about 6” from the mark and align the blue targeting pattern as shown below.
2. Move the front of the imager steadily downward toward the mark and parallel to the
mark surface.
3. The imager will decode the mark at the optimal read distancetypically from the point
of contact to .50” (contact – 12.70 mm).
Test Symbol
ABCDEFGHIJKLMNOP
Targeting LEDs
Read the configuration symbols below to enable or disable targeting LEDs.
Targeting
LED On
Targeting
LED Off
Save
Settings
POWERSCAN D8590 User’s Manual 3-3
Basic Operations
Scanning Guidelines
The POWERSCAN D8590 makes reading the most difficult direct part marks easy. The
following guidelines will help ensure optimal performance:
In the default illumination setup, allow the POWERSCAN D8590 to run through its illumination
sequences before terminating the read cycle. The POWERSCAN D8590 captures several
images with each illumination zone, evaluating the optimum settings. If reading the
same part or same part type, the POWERSCAN D8590 always uses the most recent
good read settings as a starting point so subsequent reads will be faster.
Hold the POWERSCAN D8590 still – d
o not swipe or
move the imager. Pull the trigger
and hold until a read is indicated by the green LED.
Hold the POWERSCAN D8590 such that its front surface is pa
rallel to the mark surface,
and the mark is centered. Unlike other readers that require a tilt to read, the POWERSCAN
D8590 is designed to operate this way.
Correct – Move in steadily with front
of imager parallel to surface.
The POWERSCAN D8590 features omnidirectional decoding. Centering the mark within
the field of view will yield the best decode performance.
3-4 POWERSCAN D8590 User’s Manual
Decode Zones and Lighting Zones
Decode Zones and Lighting Zones
The following chart provides a guideline for overall read performance based on mark size.
Actual range for direct part marks will vary based on mark parameters and the
illumination
zone required for readings. The chart below is intended as a guideline.
Decode Zones
POWERSCAN D8590 User’s Manual 3-5
Basic Operations
Lighting Zones
The following charts indicate the POWERSCAN D8590’s illumination zones.
Dome Lighting Zone
Dome illumination de-emphasizes surface texture and elevation (curved surface).
Dome Illumination
Texture and Elevation
are De-Emphasized on
the Mark’s Surface
3-6 POWERSCAN D8590 User’s Manual
Decode Zones and Lighting Zones
Low Angle Lighting Zone
Low Angle illumination emphasizes surfaces texture and elevation (curved surface).
Low-Angle Illumination
Texture and Elevation
are Emphasized on
the Mark’s Surface
POWERSCAN D8590 User’s Manual 3-7
Basic Operations
Illumination System
The POWERSCAN D8590 ensures reliable decoding of the toughest direct part marks.
Through an advanced combination of low angle (dark field) and multi-colored dome (bright
field) illumination techniques, the imager provides even illumination of flat, shiny surfaces,
enhancing embossed features, or differentiating features on curved surfaces.
Dome Illumination
Low Angle Illumination
Anti-Reflective Coated Window
Low Angle (Dark Field) Illumination
The low angle illumination zone provides what is called “dark field” illumination, ideal for
very low-contrast marks such as laser-embossed or engraved marks. This zone is useful
on both specular and non-specular surfaces and emphasizes surface texture. The optimum
lighting angle for most marks is 30 degrees, which occurs when the imager is approximately
0.25” away from the target mark. This illumination zone actually directs light inward at an
angle, which varies with the actual working distance and provides a good source of low
angle illumination from contact (5 degrees) to about 0.5 inch (45 degrees). Beyond this
working distance for low angle illumination the illumination zone converts to a general purpose
illuminator due to a portion of the illumination passing straight through the prism. This can
be useful in providing “bright field” illumination. This zone was designed for reading larger
marks such as 1D symbols at longer working distances.
Low Angle
Illumination
Zone 1
(Contact to
0.5”)
Low Angle
Illumination
Zone 2 (0.5”
and greater)
3-8 POWERSCAN D8590 User’s Manual
Illumination System
Dome Illumination
Dome illumination provides diffused, uniform light. The large, solid angle of illumination
supports imaging of shiny flat surfaces or curved surfaces. This zone is useful on specular
and non-specular surfaces, ideal for de-emphasizing surface texture and elevation
(curves). The dome provides the widest area of coverage at close working distances. It is
important to note that for marks that are a large percentage of the diameter of a curved
surface, closer distances will provide the best performance. In addition to illuminating
marks on curved surfaces, dome illumination also provides diffuse, even bright field illumination,
which will provide thorough coverage on a wide variety of direct part marks.
Dome Illumination
Blue Dome vs. Red Dome Illumination
The POWERSCAN D8590 features two colors of dome illumination to add another dimension
of decode optimization for direct part marks. Using the opposite light spectrum as a part’s
surface color will make the part feature appear darker. Using the same light spectrum will
make the part feature appear lighter. The example below shows a green part surface with
a laser-etched Data Matrix.
Blue Dome Illumination Red Dome Illumination
POWERSCAN D8590 User’s Manual 3-9
Basic Operations
Illumination Sequence
The POWERSCAN D8590 is configured to provide the broadest reading capabilities “out
of the box”. Just point and shoot to read most marks. This is achieved by combining the
illumination system with advanced decode algorithms. The POWERSCAN D8590 automatically
cycles through a default combination of the illumination zones each time the user pulls the
trigger to decode a mark. The imager will then lock onto the settings used in the last good
read and move those to the first step in the next sequence.
The POWERSCAN D8590 has four
steps defined
in this default illumination sequence:
1. Low Angle Illumination with Low Resolution Image
Low Angle
Illumination
2. Low Angle Illumination with Full Resolution Image
Low Angle
Illumination
3. Blue Dome Illumination
Blue Dome
Illumination
4. Red Dome Illumination
Red Dome
Illumination
With ESP Software, the user can change this sequence or define a different sequence. It
is possible to have one step to as many as eight steps defined. ESP allows the user to
evaluate the best settings.
Note: Decode speed can be improved with fewer illumination s
teps.
Note: Hovering over an uploaded image in ESP with your cursor will display the
settings
used to capture the image.
In addition to the general purpose sequence, a special sequ
ence has been defined for dot
peen marks. This adds additional X-Mode pre-processing to the sequence steps, allowing
you to read some of the most challenging direct part marks with ease.
3-10 POWERSCAN D8590 User’s Manual
Illumination Sequence
NOTES
POWERSCAN D8590 User’s Manual 4-1
4 Communications
Contents
This section includes connection parameters and options for communicating with the
POWERSCAN D8590 in various interfaces.
Communications by ESP.............................................................................................................. 4-2
Communications Overview........................................................................................................... 4-3
USB Interface ............................................................................................................................... 4-4
RS-232 Interface .......................................................................................................................... 4-5
Preamble ...................................................................................................................................... 4-7
Postamble..................................................................................................................................... 4-9
Preamble and Postamble by ESP .............................................................................................. 4-11
Keyboard Mapping .................................................................................................................... 4-12
Text Commands ......................................................................................................................... 4-13
Other Communications Settings in ESP..................................................................................... 4-14
4-2 POWERSCAN D8590 User’s Manual
Communications by ESP
Communications by ESP
To make changes to configuration settings in the Communications tree control:
2. Double click on the
parameter and click once
in the selection box to
view options.
3. Place your cursor in the
selection box, scroll down
to the setting you want to
change and click once
on the setting.
1. Left click
on the + to
expand the
tree.
4. Left click again on the open screen to complete the
selection.
5. Right click on the open screen and select Save to
Reader to implement the command in the imager.
POWERSCAN D8590 User’s Manual 4-3
Communications
Communications Overview
All POWERSCAN D8590 imagers are shipped with a USB cable. You can also add RS-232
capabilities and configure your imager accordingly. Whenever you default the imager, it
will return to the default settings of whichever interface you are using. Defaulting the imager
does not remove preamble and postamble formatting.
Note:
You must use USB Co
nnect Mode or RS-232 Connect Mode to connect to ESP.
Once the imager is connected to ESP, you can select your
communications mode and set
other communication parameters.
USB
With USB communications, the imager connects directly to the host’s USB port from which it
draws its power. Data is displayed by any open Windows-based program that can capture
text in USB Keyboard Mode.
RS-232
With RS-232 communications the imager communicates with the host through a communications
program such as HyperTerminal.
Default settings for establishing RS-232 communications are:
Baud = 57.6K
St
op Bits = 2
Data Bits = 8
Parity = None
4-4 POWERSCAN D8590 User’s Manual
USB Interface
USB Interface
USB Keyboard is the default interface in which data is transferred to a Windows-based
text program as keyboard data.
See USB Interface for detailed steps on setting up
the USB Interface.
USB Keyboard Mode
Data is entered as keyboard sequences. You need to read this symbol
whenever you are changing from a different interface to USB.
USB Downloader Mode
This mode is the standard way of transferring unformatted, unpacketized
data to the imager through the USB port.
USB Native Two-Way Mode
This mode is used when the user needs error-corrected communication
between the POWERSCAN D8590 and the USB port.
USB Virtual COM Mode
This mode allows an POWERSCAN D8590 in a USB configuration to
function as a virtual serial COM port. This mode requires installation of
a USB Virtual COM driver.
USB HID POS (Terminal ID 131)
Save
Settings
This mode allows a USB-cabled POWERSCAN D8590 to communicate
as a USB HID POS (Terminal ID 131) device.
POWERSCAN D8590 User’s Manual 4-5
Communications
RS-232 Interface
Enabling either of these modes will disable USB communications and require you to
default the imager or read the “USB Keyboard” symbol to return to USB.
See RS-232 Interface for detailed steps on setting up the RS-232 Interface.
RS-232 Default Settings
This mode is the standard way of transferring unformatted, unpacketized data through the
RS-232 port.
You will need to read this symbol whenever you set up RS-232 communications.
Baud Rate (RS-232)
Baud Rate is the rate at which the imager and host transfer data. It only needs to be
changed if necessary to match the host setting.
1200
2400
4800
9600
19.2K
38.4K
57.6K (Default)
115.2K
Save Settings
4-6 POWERSCAN D8590 User’s Manual
RS-232 Interface
Parity (RS-232)
Parity is an error detection routine in which one data bit in each character is set to 1 or 0
so that the total number of 1 bits in the data field is even or odd. It only needs to be
changed if necessary to match the host setting.
None (Default)
Odd
Even
Stop Bits (RS-232)
Stop Bits are added to indicate the end of each character. This setting should only be
changed if necessary to match the host setting.
2 Stop Bits (Default) 1 Stop Bit
Data Bits (RS-232)
Data Bits are the total number of bits in each character. This setting only needs to be
changed if necessary to match the host setting.
8 Data Bits (Default)
7 Data Bits
Save Settings
POWERSCAN D8590 User’s Manual 4-7
Communications
Preamble
A preamble is a character or series of characters that is added to the beginning of a
decoded data string. Preamble characters will appear in the order that they are enabled
(left to right). For example, if you enable a comma and then a space, and then decode a
symbol containing the data ‘ABC’, your output will look like this:
, ABC
The only limit to the number of preambles enabled is the total memory size available.
Important: Be su
re to save all se
ttings before reading any of the following preamble
symbols—otherwise your settings may be lost.
Save Settings
Set the desired preamble by reading the appropriate symbol below.
Serial Preamble
Comma
Space
Tab
Erase All
Preamble Data
Carriage Return
Line Feed
Erase Preamble
and Postamble
Data
Note: To erase
all preamble
and postamble
data, read the
symbol at right:
4-8 POWERSCAN D8590 User’s Manual
Preamble
USB or PS/2 Keyboard Preamble
Comma
Space Tab
Erase All
Preamble Data
Erase Preamble
and Postamble
Data
Note: To erase
all preamble
and postamble
data, read the
symbol at right:
POWERSCAN D8590 User’s Manual 4-9
Communications
Postamble
A postamble is a character or series of characters that is added to the end of a decoded
data string. Postamble characters will appear in the order that they are enabled (left to
right). For example, if you enable a space and then a comma, and then decode a symbol
containing the data ‘ABC’, your output will look like this:
ABC
,
The only limit to the number of postambles enabled is the total memory size available.
Important: Be sure to save all se
ttings before reading any of
the following postamble
Save Settings
symbols—otherwise your settings may
be lost.
Set the desired postamble by reading the appropriate symbol below.
Serial Postamble
Line Feed
Carriage Return
Comma
Carriage Return
Line Feed
Space
Tab
Erase All
Postamble
Data
Erase Preamble
and Postamble
Data
Note: To erase
all postamble
and preamble
data, read the
symbol at right:
4-10 POWERSCAN D8590 User’s Manual
Postamble
USB or PS/2 Keyboard Postamble
Comma
Space
Enter
Tab
Erase All
Postamble
Data
Erase Preamble
and Postamble
Data
Note: To erase
all postamble
and preamble
data, read the
symbol at right:
POWERSCAN D8590 User’s Manual 4-11
Communications
Preamble and Postamble by ESP
Characters can also be added to the beginning and end of data strings using ESP. There
are a few different ways to do this, using the interface shown below.
You will see the Communications tree control on the left, and the Preamble/Pos
tamble
interface on the right.
Scroll through a list of all preamble
and postamble options, and then
click Insert.
In addition to typing directly
in the text fields and selecting
from the dropdown menu,
you can also click any of
these preset buttons to set a
preamble or postamble.
Save pre- and postamble
settings and send them to
the imager.
When you type ASCII characters directly into the Preamble
or Postamble text fields and then click Send to Reader,
those preamble or postamble characters are enabled and
will appear in data output.
4-12 POWERSCAN D8590 User’s Manual
Keyboard Mapping
Keyboard Mapping
The Keyboard Mapping feature provides alternatives for keyboards that do not conform
to US English mapping.
Note: Universal Keyboard mapping is slightly slower
than the other language-specific
options, because it maps data by reference to the full set of ASCII characters. The
advantage of Universal Keyboard mapping is that it allows any language and keyboard
layout to be mapped.
Important: Keyb
oard Mapp
ing is not to be confused with USB Keyboard Mode, which
has an entirely different function—namely to enable USB cabled communications. (See
USB Interface).
US English, No Leading
0 for non-printable
characters (Default)
US English, Leading
0 for non-printable
characters
US English, Ctrl + char. for
non-printable characters
French German
Japanese
Universal Keyboard
Custom Keyboard
Enable Alternate OS
(Windows CE/MAC/Unix/
Linux)
Disable Alternate OS
Save Settings
Keyboard Mapping by ESP
POWERSCAN D8590 User’s Manual 4-13
Communications
Text Commands
When the Text Commands feature is enabled, the POWERSCAN D8590 can accept text
commands via RS-232 connections and USB Virtual COM modes.
Note: Text Commands are
not supported in USB HID Mode.
Enable Text
Commands
Disable Text
Commands
(Default)
Save
Settings
Text Commands by ESP
Entering Magic Sequence
The magic sequence is ;>PA followed by a numeric value of 1, 3, or 7.
1 = Enable Text Commands
3 = Enabled; Suppress Echo
7 = Enabled; Suppress Echo and Responses
In the example
below, the magic sequence entered will Enable Text Commands and
Suppress Ech
o and Responses.
Enter the magic sequence in
this text field and click Send.
Once the magic sequence has been sent, you can send text commands from the same text field.
When Text Commands are set to
Enabled; Suppress Echo, text
that a user enters in the terminal
will not be shown. When Text
Commands are set to Enabled;
Suppress Echo and Responses,
neither user-entered data or imager
responses will be shown, and only
decoded symbol data will appear in
the terminal.
See Terminal Right-Click Menu
for a way to change Echo settings
directly in the terminal view.
When Magic Sequence is enabled, it allows
the user to enable
Text Commands
by entering
a predetermined series of keystrokes.
4-14 POWERSCAN D8590 User’s Manual
Other Communications Settings in ESP
Other Communications Settings in ESP
Some
ESP
Communications options are unique to the software, and do not have corresponding
programming symbols. These options are explained below.
Reader Packet Format
Data that is sent from the imager to the host in Raw format is sent without packet framing
or check characters. One-Way communication is in a raw format, no response is expected
from the host, and data is not resent.
Packetized data
is sent with framing (a preamble communicating the amount of data to be
transmitted, and a postamble containing error detection) and check characters, and a
response is expected from the host. Two-Way communication is in packet format.
Reader to Host Packet Size
The Reader to Host Packet Size is the amount of data (in bytes) that is sent to the host in
packet format. This feature allows you to set the maximum allowable packet size.
Expect Host Response
When Expect Host Response is enabled, the imager will re-transmit data if it doesn’t
receive acknowledgement from the host.
Reader Send Retry Count
Reader Send Retry Count sets the number of times the imager will re-transmit data
before abandoning further send attempts. The minimum retry count is 1, which represents
the initial transmission.
Host Acknowledgement Timeout
The Host Acknowledgement Timeout is the amount of time (in seconds) that the imager
will wait for an acknowledgement from the host before re-sending data.
POWERSCAN D8590 User’s Manual 4-15
Communications
USB Keyboard Rate
Requests that the host polls the USB POWERSCAN D8590 at the rate specified (
1
to
255
ms).
Keyboard Inter Message Delay
Places a delay between each character that is output by the imager when in Keyboard
Mode. Useful for applications that require a slower output rate.
4-16 POWERSCAN D8590 User’s Manual
Other Communications Settings in ESP
NOTES
POWERSCAN D8590 User’s Manual 5-1
5 Read Cycle
Contents
This section contains information on how to set your imager to the most efficient and
effective parameters for your application.
Read Cycle by ESP.......................................................................................................................5-2
Button Stay-Down Time ................................................................................................................5-3
Ignore Duplicate Symbol Timeout .................................................................................................5-4
Region of Interest..........................................................................................................................5-5
5-2 POWERSCAN D8590 User’s Manual
Read Cycle by ESP
Read Cycle by ESP
To make changes to configuration settings in the Read Cycle tree control:
POWERSCAN D8590 User’s Manual 5-3
Read Cycle
Button Stay-Down Time
Button Stay-Down Time sets the amount of time (in seconds) that the imager will continue
to process the current “decode symbol” event. The imager will behave as if the trigger is
being activated for this specified amount of time.
5-4 POWERSCAN D8590 User’s Manual
Ignore Duplicate Symbol Timeout
Ignore Duplicate Symbol Timeout
Ignore Duplicate Symbol Timeout sets the imager not to output the same symbol data
multiple times within the time period designated.
POWERSCAN D8590 User’s Manual 5-5
Read Cycle
Region of Interest
Region of Interest
allows the user to determine the size of the image window to be captured
and decoded.
Note: Using a smaller Region of
Interest, if possible, may enhance read cycle performance.
Full Image (1280 x 1024) (Default)
Save Settings
Partial Image (800 x 600)
Region of Interest by ESP
5-6 POWERSCAN D8590 User’s Manual
Region of Interest
NOTES
POWERSCAN D8590 User’s Manual 6-1
6 Symbologies
Contents
This section describes the various symbol types that can be read and decoded by the imager.
Note: Disabling unused symbologies may substantially improve the POWERSCAN
D8590’s decode speed.
Symbologies by ESP.................................................................................................................... 6-2
Aztec............................................................................................................................................. 6-3
BC412........................................................................................................................................... 6-4
Codabar........................................................................................................................................ 6-5
Code 39........................................................................................................................................ 6-6
Code 93........................................................................................................................................ 6-7
Code 128...................................................................................................................................... 6-8
Composite .................................................................................................................................... 6-9
Data Matrix ................................................................................................................................. 6-10
GS1 DataBar .............................................................................................................................. 6-11
Interleaved 2 of 5........................................................................................................................ 6-12
MicroPDF417.............................................................................................................................. 6-13
PDF417 ...................................................................................................................................... 6-14
Pharmacode ............................................................................................................................... 6-15
QR Code..................................................................................................................................... 6-17
UPC/EAN.................................................................................................................................... 6-18
Symbology Identifier................................................................................................................... 6-19
6-2 POWERSCAN D8590 User’s Manual
Symbologies by ESP
Symbologies by ESP
To make changes to configuration settings in the Symbologies tree control:
4. Left click again on the open screen to complete
the selection.
5. Right click on the open screen and select Save to
Reader to implement the command in the imager.
1. Left click on the +
to expand the tree.
2. Double click on the
parameter and click
once in the selection
box to view options.
3. Place your cursor in
the selection box,
scroll down to the
setting you want to
change and click
once on the setting.
POWERSCAN D8590 User’s Manual 6-3
Symbologies
Aztec
Read the following symbols to enable/disable Aztec settings:
Aztec On
Save Settings
Aztec Off (Default)
Aztec by ESP
Sample Aztec Symbol
6-4 POWERSCAN D8590 User’s Manual
BC412
BC412
Read the following symbols to configure BC412 settings:
BC412 Off (Default) BC412 On
BC412 On, Remove Check Digit
Save Settings
BC412 by ESP
Sample BC412 Symbol
POWERSCAN D8590 User’s Manual 6-5
Symbologies
Codabar
Read the following symbols to enable/disable Codabar settings:
Codabar On (Default) Codabar Off
Save Settings
Codabar by ESP
Sample Codabar Symbol
ESP allows you to enable
a checksum, or to enable
a checksum and remove
it from the decode result.
6-6 POWERSCAN D8590 User’s Manual
Code 39
Code 39
Read the following symbols to configure Code 39 settings:
Code 39 On (Default) Code 39 Off
Enable Checksum Disable Checksum (Default)
Enable Checksum and Strip from Result
Code 39 Extended Code 39 Extended
Full ASCII On Full ASCII Off (Default)
Save Settings
Code 39 by ESP
Sample Code 39 Symbol
POWERSCAN D8590 User’s Manual 6-7
Symbologies
Code 93
Read the following symbols to enable/disable Code 93 settings:
Code 93 On (Default) Code 93 Off
Save Settings
Code 93 by ESP
Sample Code 93 Symbol
6-8 POWERSCAN D8590 User’s Manual
Code 128
Code 128
Read the following symbols to enable/disable Code 128 settings:
Code 128 On (Default) Code 128 Off
Save Settings
Code 128 by ESP
Sample Code 128 Symbol
POWERSCAN D8590 User’s Manual 6-9
Symbologies
Composite
Composite consists of a 1D component associated with an adjacent 2D component. A
successful decode is required for both the 1D and 2D components before the POWERSCAN
D8590 outputs a result. When Composite is enabled, the unit decodes the 1D component first.
Important: EAN-8, EAN-13, UPC-A, and UPC-E cannot be decoded individually when
Composite is enabled.
Read the following symbols to enable or disable Composite:
Composite On
Save Settings
Composite Off (Default)
Composite by ESP
Sample Composite Symbol
6-10 POWERSCAN D8590 User’s Manual
Data Matrix
Data Matrix
Read the following symbols to enable/disable Data Matrix settings:
Data Matrix ECC 0-140 On (Default) Data Matrix ECC 0-140 Off
Save Settings
Data Matrix by ESP
Sample Data Matrix Symbol
POWERSCAN D8590 User’s Manual 6-11
Symbologies
GS1 DataBar
Read the following symbols to configure GS1 DataBar settings:
All DataBar On (Default) All DataBar Off
DataBar Limited On DataBar-14 and DataBar-14 Stacked On
DataBar Expanded On
Save Settings
GS1 DataBar by ESP
Sample DataBar-14 Limited Symbol
Sample DataBar-14 Stacked Symbol Sample DataBar Expanded Symbol
Sample DataBar-14 Symbol
6-12 POWERSCAN D8590 User’s Manual
Interleaved 2 of 5
Interleaved 2 of 5
Read the following symbols to configure Interleaved 2 of 5 settings:
Interleaved 2 of 5 On (Default) Interleaved 2 of 5 Off
Interleaved 2 of 5 Two Digits On Interleaved 2 of 5 Two Digits Off
Interleaved 2 of 5 Four Digits On Interleaved 2 of 5 Four Digits Off
Interleaved 2 of 5 Checksum On Interleaved 2 of 5 Checksum Off
Interleaved 2 of 5 Checksum On and Strip from Result
Save Settings
Interleaved 2 of 5 by ESP
Sample Interleaved 2 of 5 Symbol
POWERSCAN D8590 User’s Manual 6-13
Symbologies
MicroPDF417
Read the following symbols to enable/disable MicroPDF417 settings:
MicroPDF417 On
MicroPDF417 Off (Default)
Save Settings
MicroPDF417 by ESP
6-14 POWERSCAN D8590 User’s Manual
PDF417
PDF417
Read the following symbols to enable/disable PDF417 settings:
PDF417 On (Default) PDF417 Off
Save Settings
PDF417 by ESP
Sample PDF417 Symbol
POWERSCAN D8590 User’s Manual 6-15
Symbologies
Pharmacode
Read the following symbols to enable/disable Pharmacode settings:
Pharmacode Off (Default)
Pharmacode On
Save Settings
Pharmacode by ESP
Fixed Symbol Length Status
When enabled, the imager will check the symbol length against the symbol length field. If
disabled, any length will be considered valid.
Symbol Length
Specifies the exact number of bars that must be present for the imager to recognize and
decode the Pharmacode symbol.
Minimum Bars
Sets the minimum number of bars that a Pharmacode symbol must have to be considered
valid.
Bar Width Status
If set to Mixed, the imager will autodiscriminate between narrow bars and wide bars. If set
to All Narrow, all bars will be considered as narrow bars. If set to All Wide, all bars will be
considered as wide bars. If set to Fixed Threshold, it will use the fixed threshold value to
determine whether the bars are narrow or wide. The Bar Width Status setting will be
ignored when the imager is able to tell the difference between the narrow and the wide bars.
6-16 POWERSCAN D8590 User’s Manual
Pharmacode
Direction
Specifies the direction in which a symbol can be read.
Fixed Threshold Value
Used when Bar Width Status is set to Fixed Threshold. Defines the minimum difference
in pixels that will distinguish a narrow bar from a wide bar.
Sample Pharmacode Symb
ol
POWERSCAN D8590 User’s Manual 6-17
Symbologies
QR Code
Read the following symbols to configure QR Code settings:
QR Code On QR Code and Micro QR Code Off
Micro QR On QR Code and Micro QR Code On (Default)
Save Settings
QR Code by ESP
Sample QR Code Symbol
Sample Micro QR Code Symbol
6-18 POWERSCAN D8590 User’s Manual
UPC/EAN
UPC/EAN
Read the following symbols to configure UPC/EAN settings:
UPC On (Default) UPC Off
UPC Expansion On (Default) UPC Expansion Off
EAN On (Default) EAN Off
Save Settings
UPC/EAN by ESP
Sample UPC-E Symbol
Sample UPC-A Symbol
POWERSCAN D8590 User’s Manual 6-19
Symbologies
Symbology Identifier
When Symbology Identifier is enabled, an AIM (Association for Automatic Identification
and Mobility) preamble is added to decoded data output (see the
AIM Symbology Identifiers
list). This preamble identifies what kind of symbology has been decoded.
Symbology Identifier On Symbology Identifier Off (Default)
Save Settings
Symbology Identifier by ESP
AIM Symbology Identifiers
A Code 39
C Code 128
d Data Matrix
e GS1 DataBar / Composite
E UPC/EAN
F Codabar
G Code 93
I Interleaved 2 of 5
L PDF417 / MicroPDF417
Q QR Code / Micro QR Code
X Other (Pharmacode)
z Aztec
6-20 POWERSCAN D8590 User’s Manual
Symbology Identifier
NOTES
POWERSCAN D8590 User’s Manual 7-1
7 I/O Parameters
Contents
This section contains information on how to set your imager to the most efficient and
effective parameters for your application.
I/O Parameters by ESP.................................................................................................................7-2
Operational Feedback...................................................................................................................7-3
Gain Control..................................................................................................................................7-4
Exposure.......................................................................................................................................7-5
Data Validation..............................................................................................................................7-6
7-2 POWERSCAN D8590 User’s Manual
I/O Parameters by ESP
I/O Parameters by ESP
To make changes to configuration settings in the I/O Parameters tree control:
POWERSCAN D8590 User’s Manual 7-3
I/O Parameters
Operational Feedback
Condition Sound/Vibration LED
Successful Power-On 1 Beep / Vibration
Sequence: AMBER
GREEN AMBER
Successful Connection with Host via USB 1 Beep / Vibration None
Successful Decode and Data Transfer to Host
1 Beep / Vibration Flash GREEN
Configuration Symbol Successful
ly Decoded
and Processed
2 Beeps / Vibrations
separated by short
pause
Flash GREEN
Beep and Vibration Modes
Read the following symbols to set beep and vibration modes.
Vibrate On /
Beep On
(Default)
Vibrate On /
Beep Off
Vibrate Off /
Beep On
Save Settings
7-4 POWERSCAN D8590 User’s Manual
Gain Control
Gain Control
Gain Control is a system that controls gain in the captured image—how bright or dark the
resulting image will be. The higher the gain, the brighter the image.
When the POWERSCAN D8590 is set to Adaptive mode, it will
automatically maintain the
proper setting for gain based on the captured image in order to produce the best setting to
perform a decode. In the Manual setting the gain is fixed to whatever value is set by gain
slider controls on the Illumination tab in I/O Parameters.
POWERSCAN D8590 User’s Manual 7-5
I/O Parameters
Exposure
The larger the Exposure value, the longer the pixels in the candidate image are exposed,
allowing the imager to collect more light.
Note: A larger exposure value may cause blurred images.
7-6 POWERSCAN D8590 User’s Manual
Data Validation
Data Validation
Data Validation is used to confirm that a decoded string from the imager has complied
with a particular company, industry, or ISO standard. POWERSCAN D8590 Data Validation
is compliant with Department of Defense Unique Identification and ISO/IEC 15434 (Information
Technology – Transfer Syntax for High-Capacity ADC Media) requirements.
Unique Identification
Unique Identification is a mandatory Department of Defense (DoD) requirement on all
solicitations issued January 1, 2004 or later. This policy mandates the use of Unique Item
Identifiers (UIIs) encoded within Data Matrix symbols on equipment and parts procured by
DoD. The POWERSCAN D8590 complies with Department of Defense Standard Practice
Identification (MIL-STD-130).
Once the imager decodes the Data Matrix symbol,
and if Unique Item Identifier (UII),
Current
Part Number (CPN), and Lot/Batch Number (LBN) are turned on, the POWERSCAN
D8590 checks the ISO/IEC 15434 syntax with ISO/IEC 15418 (ANSI MH10.8.2 – AI and
DI) and ISO/IEC 21849 (ATA – TEI) semantics to construct the UII, CPN, and LBN.
Unique Identification Features
The following data output options are applicable to Data Matrix ECC 200 symbols only and
have no effect on other symbologies.
UII Enabled Allows the imager to read only message streams encoded in Data Matrix
ECC 200 symbols, then to construct and output a UII string. The message
streams include validation of Unique Item Identifier (UII), Current Part
Number (CPN), and Lot/Batch Number (LBN) strings. When the imager
decodes a symbol but the symbol data does not compy with UII format, it
will stop capturing images and the green LED will illuminate without
beeping, vibrating, or outputing the string.
UII Enabled with
Pass Through
Allows the imager to read UII messages in Data Matrix ECC 200 symbols
and
non-UII messages in any type of symbols. The imagers behavior is
the same as with UII Enabled.
UII Enabled with
Error Messages
Allows the imager to read UII messages in Data Matrix ECC 200 symbols
and output det
ailed information such as construction type, data components,
or error messages. The imager’s behavior is the same as with UII
Enabled.
Data Validation
Disabled
Disables both UII and ISO/IEC 15434 data validation.
POWERSCAN D8590 User’s Manual 7-7
I/O Parameters
Unique Identification Output Examples
UII Enabled
UII:UN123456789ABCDEFG
CPN:87654321
LBN:87654321
UII:12345678 CPN:87654321
UII:12345678 LBN:87654321
UII Enabled with Pass Through
UII:UN123456789ABCDEFG
CPN:87654321
LBN:87654321
UII:12345678 CPN:87654321
UII:12345678 LBN:87654321
DATA:Datalogic
UII Enabled with Error Messages
UII:UN123456789ABCDEFG;Construct_1;25SUN123456789ABCDEFG;;;;;;
CPN:87654321;PNR;PNR 87654321;;;;;;
LB
N:87654321;30T;30T87654321;;;;;;
UII:12
345678 CPN:87654321;Construct_1_2/PNR;UID 12345678
;PNR 87654321;;;;;
UII:12345678 LBN:87654321;Construct_1/30T;
25S12345678;30T87654321;;;;;
(15434 ERROR: HEADER - 1ST POSITION);Datalogic
Data Validation Disabled
The imager will return to normal output behavior without performing data validation.
7-8 POWERSCAN D8590 User’s Manual
Data Validation
ISO/IEC 15434
ISO/IEC 15434 specifies a transfer structure, syntax, and coding of messages and data
formats when using high capacity automatic data capture (ADC) technologies.
The following ISO/IEC 15434 data output options are applicable to Data Matrix ECC 200
symbols only a
nd have no effect on other symbologies.
ISO/IEC 15434
Enabled
Allows the imager to read only ISO/IEC 15434-compliant message
streams in Data Matrix ECC 200 symbols then output the ISO/IEC 15434
string. This implementation only checks the header/trailer format and
proper format indicator (00-99 and DD). The output string has a prefix, a
format indicator, and data components.
ISO/IEC 15434
Enabled with Erro
r
Messages
Allows the imager to read only ISO/IEC 15434-compliant messages in
Dat
a Matrix ECC 200 symbols and output detailed information such as
prefix, format indicator, data components, or error messages.
Data Validation
Disabled
Disables both UII and ISO/IEC 154
34 data validation.
ISO/IEC 15434 Output Examples
ISO/IEC 15434 Enabled
(15434);05;0100061414199999;211A0B9C3D6;;;;;
(15434);06;7L0A1B3C;1P4202435;S10936;;;;
(15434);06;17V0A1B2;1P42
02435;S10
936;;;;
ISO/IEC 15434 Enabled with Error Messages
(15434);05;0100061414199999;211A0B9C3D6;;;;;
(15434);06;7L0A1B3C;1P4202435;S10936;;;;
(15434);06;17V0A1B2;1P42
02435;S10
936;;;;
(15434 ERROR: HEADER - 3RD POSITION);[)<DDCAG 12345
SER
67890123▲♦;;;;;;;
(15434 ERROR: TRAILER - END OF TRANSMISSION);[)>12CAG 1234
5SER
67890123▲♣;;;;;;;
(15434 ERROR: HEADER - GROUP SEPARATOR);[)>12CAG 12345029SER
6789
0123▲♦;;;;;;;
Data Validation Disabled
The imager will return to normal output behavior without performing data validation.
POWERSCAN D8590 User’s Manual 7-9
I/O Parameters
Data Validation Settings
The following symbols control Data Validation functions:
Data Validation
Disabled (Default)
Save Settings
UII Enabled with
Error Messages
ISO/IEC 15434
Enabled
ISO/IEC 15434 Enabled
with Error Messages
UII
Enabled
UII Enabled
with Pass Through
Data Validation by ESP
Each of the Data Validation Settings can also be enabled in ESP’s I/O Parameters tree
control.
7-10 POWERSCAN D8590 User’s Manual
Data Validation
Detailed Output Format
The table below describes data validation output in detail.
Note: UII Enabled with Pass Through will add the prefix DA
TA to non-UII output for all
symbologies.
Note: UII Enabled with Error Messages will output
the following format: UII/CPN
/LBN;
DF0; DF1; DF2; DF3; DF4; DF5; DF6; DF7.
Note: When IS
O/IEC 15434 o
utput is in compliance with the standard, the format is
(15434); DF0; DF1; DF2; DF3; DF4; DF5; DF6; DF7. When it is not in compliance with
the standard, the output is (15434 ERROR: xxxx);;;;;;;; where DF0 is the format indicator
showing which type of data qualifier is in use.
UII Enabled
Content of Decoded Data
Matrix
Symbol
UII/CPN/LBN
Valid UII
UII:UII_
data
Example: UII:12345678
Valid CPN
Valid LBN
CPN:CPN_data
Example: CPN:87654321
LBN:LBN_dat
a
Example: LBN:87654321
Valid UII and CPN
Valid UII and LBN
UII:UII_data CPN:CPN_data
Example: UII:12345678 CPN:876
54321
UII:UII_data LBN:LBN_data
Example: UII:123456
78 LBN:876
54321
Valid UII and Invalid CPN
Valid UII and Invalid LBN
UII:UII_data (CPN ERROR)
Example: UII:123456
78 (CPN ER
ROR)
UII:UII_data (LBN ERROR)
Example: UII:123456
78 (LBN ERROR
)
Invalid UII and Valid CPN
Invalid UII and Valid LBN
(UII ERROR) CPN:CPN_data
Example: (UII ERROR)
CPN:87654321
(UII ERROR) LBN:LBN_data
Example: (UII ERROR)
LBN:87654321
None of the above
(Invalid UII; Invalid CPN;
Inva
lid LBN; Invalid
UII and
Invalid CPN; Invalid UII and
Invalid LBN)
No output data
POWERSCAN D8590 User’s Manual 7-11
I/O Parameters
UII Enabled with Error Messages
Content of Decoded Data
Matrix
Symbol
UII/CPN/LBN DFO
Valid UII
UII:UII_data
Example: UII:12345678
Const
ructed UII type
Example: Contruct_1
Valid CPN
Valid LBN
CPN:CPN_data
Example: CPN:87654321
LBN:LBN_dat
a
Example: LBN:87654321
Co
nstructed CPN type
Example: PNR
Constructed LBN type
Example: 30
T
Valid UII and CPN
Valid UII and LBN
UII:UII_data CPN:CPN_data
Example: UII:12345678
CPN:876
54321
UII:UII_
data LBN:LBN_data
Example: UII:12345678
LBN:87654321
Constructed UII/CPN type
Example: Con
struct_1/PNR
Constructed UII/LBN type
Example: C
ons
truct_1/30T
Valid UII and Invalid CPN
Valid UII and Invalid LBN
UII:UII_
data (30P ERROR:
xxxx)
UII:UII_
data (PNR ERROR:
xxxx)
UII:UII_
data (240 ERROR:
xxxx)
UII:UII_
dat
a (30T ERROR:
xxxx)
Const
ructed UII type
Example: Construc
t_1
Invalid UII and Valid CPN
Invalid UII and Valid LBN
(UII ERROR: xxxx)
CPN:CPN_data
(UII ERROR: xxxx)
LBN:LBN_data
Constructed CPN type:
30P, PNR, 240
Constructed LBN type:
30T
Invalid UII
(UII ERROR: xxxx)
(15434 ERROR: xxxx)
Example: (UII ERROR: DA
TA
ELEMENT CHARACTER)
Origin
al decoded data
Invalid CPN
Invalid LBN
(30P ERROR:xxxx)
(PNR ERROR:xxxx)
(240 ERROR:xxxx)
(30T ERROR:xxxx)
(15434 ERROR: xxxx)
Original decoded data
Invalid UII and Invalid CPN
Invalid UII and Invalid LBN
(UII ERROR: xxxx) (30P
ERROR: xxxx)
(UII ERROR: xxxx) (PNR
ERROR: xxxx)
(UII ERROR: xxxx) (240
ERROR: xxxx)
(UII ERROR: xxxx) (30T
ERROR: xxxx)
Original decoded data
7-12 POWERSCAN D8590 User’s Manual
Data Validation
Error Messages
The following is a list of potential error messages.
15434 ERROR: DATA ELEMENT SEPARATOR
15434 ERROR: DOUBLE TRAILER
15434 ERROR: FORMAT INDICATOR
15434 ERROR: HEADER - 1ST POSITION
15434 ERROR: HEADER -
2ND POSITION
15434 ERROR: HEADER -
3RD POSITION
15434 ERROR: HEADER - 4TH POSITION
15434 ERROR: HEADER - GROUP SEPARATOR
15434 ERROR: TRAILER - END OF TRANSMISSION
15434 ERROR: TRAILER - RECORD SEPARATOR
PNR ERROR: TOO LONG
PNR ERROR: TOO SHORT
PNR ERROR: CHARACTER
30P ERROR: TOO LONG
30P ERROR: TOO SHORT
30P ERROR: CHARACTER
240 ERROR: TOO LONG
240 ERROR: TOO SHORT
240 ERROR: CHARACTER
UII ERROR: DATA ELEMENT CHARACTER
UII ERROR: DATA ELEMENT TOO LONG
UII ERROR: DATA ELEMENT TOO SHORT
UII ERROR: LOWER CASE CHARACTER
UII ERROR: NEED UII ELEMENT FIRST
UII ERROR: SPACE AFTER T
EI DATA QUALIFIER
UII ERROR: TEI DATA QUALIFIER
UII ERROR: UII ELEMENT INCOMPLETE
UII ERROR: WRONG FORMAT INDICATOR
UII ERROR: UII STRING TOO LONG
Additional Notes
DF1 – DF7: If the UII/CPN field is “(15434 ERROR: xxxx)”, DF1 – DF7 are filled in with
an empty string. Otherwise, the fields are used to display data elements. If there are
fewer than seven data elements, an empty string is filled in at the end. If there are more
than seven elements, only the first seven elements are displayed.
There is a space between UII and CPN in both t
ables (UII:12
345678 CPN:87654321).
The constructed UII type can be Contruct_1, Contruct_2, Construct_1_2, or
IUID_EQUIV
ALENT.
The constructed CPN type can be PNR, 30P, or 240. The constructed LBN type can be 30T.
POWERSCAN D8590 User’s Manual 8-1
8 Advanced Operations
Contents
This section introduces several settings that can be applied to speed up processing or
improve readability in various circumstances.
Dot Peen Enhanced Illumination Settings .................................................................................... 8-2
Illumination Settings by ESP ........................................................................................................ 8-3
Lock Settings................................................................................................................................ 8-6
8-2 POWERSCAN D8590 User’s Manual
Dot Peen Enhanced Illumination Settings
Dot Peen Enhanced Illumination Settings
The POWERSCAN D8590’s Dot Peen Enhanced illumination settings can be controlled
using the configuration symbols shown here. They can also be controlled in ESP’s
EZ Mode
.
Note: The illumination default mode will reset the imagers illumination settings to factory
default.
Dot Peen Enhanced Illumination
Mode - Large Mark
Illumination
Default Mode
Save Settings
Dot Peen Enhanced Illumination
Mode - Medium Mark
Dot Peen Enhanced Illumination
Mode - Small Mark
POWERSCAN D8590 User’s Manual 8-3
Advanced Operations
Illumination Settings by ESP
The POWERSCAN D8590’s illumination settings can also be controlled using the graphic
interface on the Illumination tab in ESP’s I/O Parameters view.
Define how many illumination
steps (1 - 8) the imager will cycle
through during its
sequence.
Click Create Bar Code to
encode illumination
settings
in a programming
symbol.
Click this button to default
settings for the imager’s
illumination sequence.
Gain can be controlled using
the sliders shown in each Step
dialog when the Gain Control
Manual box is checked.
Select Low
Resolution
Image for
larger symbols.
Image Enhance
features apply
advanced image
processing to
improve the
readability of the
mark.
8-4 POWERSCAN D8590 User’s Manual
Illumination Settings by ESP
Image Enhance Settings
Image Enhance settings apply morphological pre-processing (erosion and dilation) to
symbol cells to improve readability. Symbols that are under-marked or over-marked can
benefit from Image Enhance settings. The Grow Dark and Grow Light checkboxes allow
you to determine which cells will be enhanced (grown).
Click Grow Dark or Grow
Light on the Illumination tab
in I/O Parameters to improve
decode performance on
under-marked or over-marked
direct part marks.
Red Dome Illumination
Without Image Enhance
Red Dome Illumination With
Image Enhance – Grow Dark
(Medium Mark Size)
Grow Dark
Grow Dark enhances the symbol’s dark cells.
Note: Grow Dark corresponds with the morphological process of erosion.
Grow Light
Grow Light enhances the symbol’s light cells.
Note: Grow Light corresponds with the morphological process of dilation.
POWERSCAN D8590 User’s Manual 8-5
Advanced Operations
Low Resolution Image
Low Resolution Image reduces the number of pixels in the image by 50%, which is
helpful when the symbol to be decoded has a large number of pixels per element (e.g. a
large Data Matrix with a 100 mil cell size, or a 1D symbol with large bar widths). This
feature improves processing speed, because the image sizes are smaller.
Note:
Low Resolution with Low Angle is the first step in the POWERSCAN D8590’s illumination
sequence, because it covers the widest range of potential candidate symbols.
14x14 – 1.5 in
2
100 mil Cell Size
Without Low Resolution
14x14 – 1.5 in
2
100 mil Cell Size
With Low Resolution
Click Low Resolution
Image on the Illumination
tab in I/O Parameters to
speed up processing.
8-6 POWERSCAN D8590 User’s Manual
Lock Settings
Lock Settings
Read the symbols below to lock or unlock imager settings.
Note: This feature does not lock preamble and postamble programming symbols, Clear
XML Rules,
or postamble erase/none commands.
Unlock Imager
Settings
Lock Imager
Settings
Save Settings
POWERSCAN D8590 User’s Manual 9-1
9
Terminal
Contents
This section describes the Terminal interface and macro functions in ESP.
Terminal View................................................................................................................................9-2
Find ...............................................................................................................................................9-3
Send..............................................................................................................................................9-4
Macros...........................................................................................................................................9-5
Terminal Right-Click Menu............................................................................................................9-6
Terminal Dropdown Menu.............................................................................................................9-7
9-2 POWERSCAN D8590 User’s Manual
Terminal View
Terminal View
Click the Terminal button.
You will see the following view:
Type text
commands
here.
Click on desired
macro to run.
Click on Macros arrow to Add Macro,
Remove Macro, or Edit Macro.
Macros listed
on this bar.
Te rmina l
screen
Type text here to
find matching text in
the terminal window.
Clear screen, copy,
paste, save.
The Terminal interface allows you to send commands to the imager by using macros, by
copying and pasting, or by typing commands in the Send text field.
The Terminal view also displays symbol data or
information from the imager.
You can also right click on the Terminal screen to
bring up a menu of further options.
POWERSCAN D8590 User’s Manual 9-3
Terminal
Find
The Find function allows you to enter text strings to be searched for in the terminal window.
For example, suppose a series of symbols have been scanned into the terminal view and
you want to determine if a particular symbol whose data begins with “ABC” has been read.
1. Type “ABC” into the Find box.
2. Press Enter.
The first instance of “ABC” will be highlighted in the terminal window.
3. Click the Find button to the le
ft of the text field to locate additional instances of
“ABC”.
9-4 POWERSCAN D8590 User’s Manual
Send
Send
The Send function allows you to enter text commands and then send them to the imager.
(See Text Commands.)
For example, suppose you want to disable the vibrate function in the imager. T
o disable
vibrate using a text command, you would enter “P%A10” (the command that disables
vibrate) in the text field and click Send.
Type text commands in
the text field and then
click the Send button to
initiate. Clicking Send
repeatedly will initiate the
command repeatedly.
Click here to access the
dropdown menu of stored
text commands.
Once text commands are initiated, they are saved in a dropdown menu that can be
accessed by clicking the arrow to the right of the text field.
You can also send the current command repeatedly by clicking
the Send button repeatedly.
POWERSCAN D8590 User’s Manual 9-5
Terminal
Macros
Macros can be stored in a macro selection bar, edited in a separate window, and executed
by clicking on the macro name.
Click on the first arrow here to see Add Macro, Default Macros, and
Move to Start.
When you default macros, the entire macros set is restored to original
commands.
Click on Next
Row to see the
next set of
macro buttons.
Click on all subsequent arrows
to Edit the associated macros.
When you click Move to Start, the names
of all the macros appear, as shown at left.
Choose which macro button you want to
appear in the first position at the bottom
of the terminal view.
Clicking on a macro button executes the related command. The command is also sent to
the imager at the same time it is displayed.
Editing a Macro
When you click the arrow next to a any macro and select Edit, the following dialog appears:
You can edit an existing
macro or type in the Macro
Name text field and define it
in the Macro Value text field.
9-6 POWERSCAN D8590 User’s Manual
Terminal Right-Click Menu
Terminal Right-Click Menu
Right click in the terminal window to display the following menu:
Copy selected text to clipboard.
Paste from terminal or other text.
Clear all text in terminal window.
Select All text in the terminal window.
Save... incoming and outgoing data into a text file.
Change Font... of data received from the imager.
Change Echo Font...
to change the appearance of user-entered
data.
Disable Echo to hide user-entered data.
Change Background Color of the terminal window.
Non-Printable Characters can be shown or hidden in the
terminal view in Standard or Enhanced format.
Default Settings to return all of the above to original settings.
Keyboard Macros brings up the Function Keys dialog,
which allows you to create customized macro functions.
Function Keys
The Function Keys dialog allows you to assign commands to specific function keys on
a standard keyboard. Note that the F1 key is reserved for opening ESP Help, and the F3
key is reserved for the Find Next function.
Select the desired function key and
then enter your macro keystrokes in
the associated key map.
For example, to make Ctrl-F2 the
keystroke to send a trigger character,
select F2, then in the Ctrl text field,
enter <trigger character> and click
OK. Then whenever Ctrl-F2 is
keyed, the trigger character will start
the read cycle.
Note: This feature is also available from the Terminal Dropdown Menu and the Terminal
tab of the Preferen
ces dialog.
POWERSCAN D8590 User’s Manual 9-7
Terminal
Terminal Dropdown Menu
The terminal dropdown menu allows you to capture and save current text, and it also
includes the functions defined for the Terminal Right-Click Menu.
Capture Text... lets you append data in real time to
a text file of your choice. While in operation, the
text file cannot be opened. You can select Pause to
interrupt the capture flow or Stop to end the flow
and open the file.
Save Current Text... saves all text in the terminal
window to a text file of your choice.
Find Next locates the next instance of the specified
data string in the terminal. This function can also be
activated by pressing F3.
Find Previous locates the most recently occurring
instance of the specified data string in the terminal.
Keyboard Macros brings up the Function Keys
dialog, which allows you to create customized
macro functions.
9-8 POWERSCAN D8590 User’s Manual
Terminal Dropdown Menu
NOTES
POWERSCAN D8590 User’s Manual 10-1
10
Utilities
Contents
This section explains ESP’s Utilities features. These include Device Control, an interface
that lets you
perform major operations with one click;
Differences from Default
, which
shows all currently
enabled POWERSCAN D8590 settings that are not default settings;
Firmware, where you can update your imager’s firmware;
and
Advanced
, which allows you
to collect batch files for customized
imager configuration and optimization.
Device Control.............................................................................................................................10-2
Differences from Default .............................................................................................................10-3
Firmware .....................................................................................................................................10-4
Advanced ....................................................................................................................................10-6
10-2 POWERSCAN D8590 User’s Manual
Device Control
Device Control
This feature allows you to clear data stored in the imagers memory, to default the imager,
to deactivate or clear XML rules, to upload or delete stored errors, to reboot the imager,
and to delete stored results.
Clear All Data removes decoded symbol data and commands in the imagers memory.
Default Reader returns the imager to its default state, without any optimization or
configuration.
Deactivate XML Rules turns off, but does not erase, preambles, postambles, and
XML commands.
Clear XML Rules removes preambles, postambles, and other XML commands.
Reboot Reader refreshes the imager’s memory and functionality, returning it to the
most recent configuration you have saved.
Delete Stored Results erases logged data.
POWERSCAN D8590 User’s Manual 10-3
Utilities
Differences from Default
Clicking the
Differences from Default
button will cause
ESP
to check all stored configuration
settings and compare them to default settings. All settings that are different from default
will appear in the left column (shown below), and descriptions of those settings will appear
in the right column.
Click this button for a list of ESP
configuration settings that are
different from default settings.
Click Generate Bar Code to bring up the Bar Code
Configuration dialog. Then create symbols containing
the configuration commands of your choice.
Click Save As to save the
report as plain text or a
tab-delimited text file.
Send configuration settings
to the imager without saving
by clicking Send to Reader.
Send configuration settings to the
imager and save in ESP by
clicking
Send and Save
.
To create a symbol containing any of the command settings in the table, click Generate
Bar Code. This will bring up the Bar Code Configuration dialog.
To save the Differen
ces from Default report, either as plain text or as a tab-delimited
text file, click Save As.
Click Send and Save to
send the settings to the imager and save them, or Send to
Reader to send the settings without saving them.
10-4 POWERSCAN D8590 User’s Manual
Firmware
Firmware
The Firmware view in ESP Utilities is a simple way to update and verify your imager’s
firmware and to update batch files.
Choose App Code from the Firmware Update dropdown menu
and click Start to install new firmware in the imager.
Use this dropdown menu to
locate batch files in the host
computer’s file directory.
Download the needed files
directly to the imager by
clicking the Start button.
The Firmware Verification tool
sends a direct query to the imager
for its Application Code Version,
Firmware Version, Boot Code
Version, and Radio Version.
Note: To ensure correct operation, cycle power to the imager (turn the imager
off and then on) after the firmware update is complete.
POWERSCAN D8590 User’s Manual 10-5
Utilities
Imager ID
Another way to query the imager for its identifying information is by reading the following
symbol:
Imager ID
@.U|.J.X.ap/i42440138none00100911810200016040002422700170001.35-617001-10 006
The host’s text program will output a data string containing the imager’s identifying
information in the following format:
Boot code version
Serial number
Hardware type
Hardware version
Firmware version
Build number
Save Settings
10-6 POWERSCAN D8590 User’s Manual
Advanced
Advanced
The Advanced tab in Utilities features an archive of all batch files containing imager
configuration commands. Each batch file’s extension is .crb, and each file contains the
fundamental code for programming the imager. Notice that the names of the batch files
correspond with the numbers beneath all the Data Matrix configuration symbols.
This tool allows you to use the batch file data to cr
eate yo
ur own symbols, or to collect only
the files that you use frequently to configure the imager for your application.
The Download Collection and Save Collection
As... buttons allow you to acquire the entire
contents of the batch file archive and save the
files in a location of your choice.
Scroll through the list of batch files in
the archive and choose the ones you
need. Move them to the collection
window using the Add arrow. Files
can also be transferred by clicking
and dragging.
The single Remove arrow functions
in the same way as the Add arrow,
except that it transfers files back to
the batch archive. The double
Remove arrow allows you to transfer
all files simultaneously.
POWERSCAN D8590 User’s Manual A-1
Appendices
Appendix A General Specifications ..............................................................................................A-2
Appendix B Electrical Specifications ............................................................................................A-4
Appendix C Default/Reset Procedure...........................................................................................A-7
Appendix D Maintenance ............................................................................................................. A-8
Appendix E Troubleshooting ........................................................................................................A-9
A-2 POWERSCAN D8590 User’s Manual
General Specifications
Appendix A — General Specifications
Mechanical
Height: 7” (180 mm)
Width: 2.5” (63 mm)
Depth: 4.5” (114 mm)
We
ight: 7.2 oz. (204 g) (not includi
ng cable)
Environmental
Operating temperature: 0° to 50° C
(32° to 122° F)
Storage temperature: –20° to 65° C
(–4° to 150°F)
Humidity: 5 to 95% (non-condensing)
Shock: Withstands >50 drops of 6’ (1.8 meters) to concrete
Illumination
Combination Dome and Low Angle illumination system.
Dome: 2-color, 640nm (red) and 470nm (blue)
Low Angle: Quadrant 30
°
, 640nm (red)
Symbologies
Aztec, BC412, Codabar, Code 39, Code 93, Code 128,
Data Matrix (ECC 0-200), GS1 DataBar, Interleaved 2 of
5, MicroPDF417, Micro QR Code, PDF417, Pharmacode
QR Code, UPC/EAN
Image Collection Options
Sensor: CMOS
Sensor Array: 1280 x 1024
Communication Protocols
Standard Interface: USB, RS-232
Read Parameters
Rotational Tolerance: ±180°
Focal Range: 0 to 2” (0 to 50.8 mm)
Focal Point: Optimal at 0.25” (6.3 mm)
Field of View: Horiz. 1.59” (40.39 mm) x Vert. 1.27” (32.31
mm) at optimum focus
Print Contrast Resolution: 20% minimum contrast
Ambient Light Immunity: Sunlight: Up to 9,000 ft. candles,
96,890 lux
Indicators
Status Indicators: Vibration motor, audible tones, visual
feedback with multi-color LED, blue-line targeting pattern
Image Output Options
Format: JPEG, TIFF
Electrical
Power Requirements: 5 VDC (mA)
Typical: 408mA Peak: 500mA Idle: 285mA
POWERSCAN D8590 Dimensions
Front View
Side View
Detail A
Use #2-56 hardware; do not exceed .115” depth.
Note: For training accessories only; not for mounting purposes.
Detail A
Note: Nominal
dimensions
shown. Typical
tolerances
apply.
POWERSCAN D8590 User’s Manual A-3
Appendices
Safety Certifications
FCC, CE, RoHS/WEEE
Copyright ©2013
Datalogic S.p.A.
All rights reserved. Specifications subject to change.
Product specifications are given for typical performance at 25°C (77°F) using grade A labels. Performance characteristics
may vary at high temperatures or other environmental extremes.
Read Ranges
Options
Accessories
PD8590-DPM POWERSCAN D8590 DPM Imager
CAB-532-KUS Kit, RS-232, 8’ coiled, US power supply
CAB-532-KEU Kit, RS-232, 8’ coiled, EU power supply
CAB-532-KUK Kit, RS-232, 8’ coiled, UK power supply
A-4 POWERSCAN D8590 User’s Manual
Electrical Specifications
Appendix B — Electrical Specifications
Power Requirements: 5 VDC (mA)
Typical: 408mA; Peak: 500mA, Idle: 285mA
PIN 1 VIN- Input Voltage to the voltage regulators/battery charging IC
PIN 2 RS-232_TX - RS-232 level serial transmit signal
PIN 3 RS-232_RX - RS-232 level serial receive signal
PIN 4
PS/2_DATA_UART_RX_USB_DP - PS/2 clk to host/ UART transmit signal/ USB
D
ata plus signal
PIN 5
PS/2_DATA_UART_RX_USB_DM - PS/2 data to host or keyboard/ UART receive
signal/ USB Data
minus signal
PIN 6 PS/2_CLK_KB - PS/2 clock signal to the keyboard
PIN 7 ~TRIG - trigger from the handle
PIN 8 GND - signal ground
Shield Shield Ground
POWERSCAN D8590 User’s Manual A-5
Appendices
USB Cable Pinouts
1,828.80 mm
A-6 POWERSCAN D8590 User’s Manual
Electrical Specifications
RS-232 Cable Pinouts
177.80 mm
1,066.80 mm
165.10 mm
POWERSCAN D8590 User’s Manual A-7
Appendices
Appendix C — Default/Reset Procedure
If the POWERSCAN D8590 locks up or becomes unresponsive, or if you would like to
clear all configuration and programming from the imager, follow the procedure below.
Important: The following procedure will clear
the buffer, default configuration, and XML
programming, including Preamble and Postamble.
1. Unplug the POWERSCAN D8590 from the PC.
2. While holding down the trigger, plug the reader into
the USB port on the PC. You will
hear five rapid beeps.
3. Let go of the trigger after the five rapid beeps. The imager is now in Boot Mode.
4. Hold down the trigger again for approximately five seconds until it reboots. The imager
will vibrate firs
t and then beep several times.
5. The imager should now operate in default mode. Save the d
efault settings by reading
this symbol:
A-8 POWERSCAN D8590 User’s Manual
Maintenance
Appendix D — Maintenance
The POWERSCAN D8590 provides reliable and efficient operation with a minimum of
care. Although specific maintenance is not required, the following periodic checks ensure
dependable operation.
Cleaning the POWERSCAN D8590 Window
The POWERSCAN D8590 has a clear, anti-reflective coated optical window that protects
the POWERSCAN D8590
illumination system and optics. The window should be clean to allow
optimum performance.
The POWERSCAN D8590 uses technology that is much like a digital
camera, and marks or debris on
the window will interfere with image captures. Avoid touching
the coated surface, as fingerprints
may impede decode performance.
In many cases the window can be cleaned by wiping with a lint-free lens cloth to remove
dust, de
bris, and fingerprints. Care should be taken not to apply too much pressure, as a
trapped particle may scratch the window.
If cleaning of the window becomes necessary, follow this procedure:
Use a minimal amount of Isopropyl Alcohol to dampen. Do not saturate
the surface, as
this may cause streaking.
Drag the moistened cotton swab, cotton ball, or soft, clean cloth across the coated surface.
Do not rub.
Repeat this procedure until no contaminants remain.
Note: Many products designed
for cleaning plastic lens eyewear, such as pre-moistened
towelettes or lens cloths, can be used to clean the POWERSCAN D8590 window.
Cleaning the POWERSCAN D8590 Housing
If the housing becomes dirty, clean it with a soft, non-abrasive cloth that has been moistened
with water. A mild detergent may be used to clean the housing, but the detergent should
then be rinsed away with a water-moistened cloth.
Caution: Do not submerge the
PO
WERSCAN D8590 in water. The housing is not water-
tight. Do not use abrasive cloths or tissues on the POWERSCAN D8590 window — abrasive
cl
oths or tissues may scratch the window.
POWERSCAN D8590 User’s Manual A-9
Appendices
Appendix E — Troubleshooting
Problem: No Data Output.
When the trigger is pulled, the unit beeps and then triple-beeps, but does not output data.
Error Messages (String Output): None.
Possible Ca
use: POWERSCAN D8590 is not con
nected (USB or Serial) to the PC.
Solution:
1. Check to make sure the PC supports “High
Power Devices”
(self-powered hubs, some
laptops, etc.). Right-click on
My Computer
in the Windows
Start
menu, select
Properties
,
click the Device Manager button on the Hardware tab, expand the Universal Serial
Bus controllers menu item, right-click on USB Root Hub, select Properties, and
then select the Power tab.
2. Make sure the PC is not allowed to power down the device. Follow the same path
described above, but select the Power Management tab instead of the Power tab.
Uncheck the Allow the
computer to turn off this
device to save power
box if it is checked.
A-10 POWERSCAN D8590 User’s Manual
Troubleshooting
Problem: No Illumination – License Key Failed.
The unit is unable to decode, and it is not cycling through its illumination settings. (Targeting,
if enabled, does appear when the trigger is pulled.)
Error Messages (String Output): “License Key Failed”
Possible Cause: Th
e POWERSCAN D859
0 license has been deleted.
Solution: Request license file (2019_(serial number).crb) from Datalogic
customer support.
Unit serial number and license must match.
Once you have received the license file
from customer support, go to the Utilities
section of ESP, browse for the file in the
Batch File Update field, and click Start
once you have located the file.
Problem: No Illumination – No Process Sequence Defined.
The unit is unable to decode, and it is not cycling through its illumination settings. (Targeting,
if enabled, does appear when the trigger is pulled.)
Error Messages (String Output): “No Pro
cess Sequence Defined; Please Set the Unit to
Default Settings”
Possible Cause: No illumination sequence has been defined
for the POWERSCAN D8590.
Solution: Reset the default illumination sequence
.
If Sequence Steps is set to 0, the illumination
sequence will not occur.
Click the Default button to
return to 4 illumination steps.
Datalogic ADC, Inc.
959 Terry Street
Eugene, OR 97402
USA
Telephone: (541)
683-5700
820057190 (Rev A) May 2013
www.datalogic.com
116


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Datalogic PowerScan PD8590-DPM at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Datalogic PowerScan PD8590-DPM in the language / languages: English as an attachment in your email.

The manual is 2,57 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info