Quick Reference Guide 13
Defaults
For your convenience, standard factory defaults
1
are shown here for each of the major interface
types. For more details or to change these settings, reference the Product Reference Guide (PRG).
RS-232 Standard Default Settings:
9600 Baud, no Parity, 1 Stop Bit, Handshaking dis-
abled, no Intercharacter Delay, Beep on ASCII BEL disabled, Beep On Not On File enabled, ACK
Character = ACK’, NAK Character = ‘NAK’, ACK NAK Timeout Value = 600ms, ACK NAK
Retry Count = 3, ACK NAK Error Handling = Ignore, Indicate Transmission Failure enabled, Dis-
able Reader Command = ‘D’, Enable Reader Command = ‘E’.
Wand Emulation Standard Default Settings:
Wand Idle State = Low, Wand Polarity =
Quiet Zones & Spaces High - Bars Low, No Label Symbology Conversion, Transmit Noise = Dis-
abled.
OEM/IBM Standard Default Settings:
OEM-USB Device Usage = Table Top Reader,
Transmit Labels in Code 39 Format = OEM Standard Format, 46xx Number of Host Resets = 6.
USB Standard Default Settings:
USB Keyboard Speed = Fast (1ms).
Keyboard Standard Default Settings (Keyboard AT):
Country Mode = U.S., Caps
Lock= OFF, Numlock Key =Unchanged, Send Control Characters = Disabled, Wedge Quiet Inter-
val = 100ms, No Wedge Intercode Delay.
Enabled Symbologies
UPC-A, UPC-E, EAN 13, EAN 8 without add-ons, Check Character Transmission
enabled, no Expansion, Minimum Reads = 1 (except In-Store Minumum Reads = 2), Sys-
tem Number Transmission = enabled, 2D Components = disabled, EAN 8 Guard Inser-
tion/Substitution Options = disabled (except EAN 8 Guard Substitution), Stitching =
disabled.
Code 39 Check Character Calculation/Transmission enabled, Start/Stop Character dis-
abled, Full ASCII disabled, Quiet Zones = auto, Minimum Reads = 1, Decoding Level and
Aggressiveness = 3, Variable Length Control, Length One = 2, Length Two = 50, Interdigit
Ratio = 4, Character Correlation = Disabled, Stitching is enabled.
Code 128 No Expansion, Check Character Transmission enabled, SubCode Change not
transmitted, Quiet Zones = Auto, Minimum Reads = 1, Decoding Levels and Aggressive-
ness = 3, Variable Length Control, Length One = 1, Length two = 80, Character Correla-
tion = disabled, Stitching = enabled.
Interleaved 2 of5—ZeroPattern and Check Character Calculation = disabled, Check
Character Transmission = enabled, Minimum Reads = 1, Decoding Levels and Aggressive-
ness = 3, Variable Length Control, Length One = 12, Length Two = 100, Character Corre-
lation and Stitching = disabled.
1. Applicable only when the reader is connected to a host via the Base Station.
15


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Datalogic PowerScan PBT7100 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Datalogic PowerScan PBT7100 in the language / languages: English as an attachment in your email.

The manual is 1,2 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Datalogic PowerScan PBT7100

Datalogic PowerScan PBT7100 User Manual - English - 20 pages

Datalogic PowerScan PBT7100 User Manual - Spanish - 24 pages

Datalogic PowerScan PBT7100 User Manual - Spanish - 20 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info